5930-00-631-3039

SWITCH,PRESSURE


5930-00-631-3039 (5930006313039, 006313039)
Part Number (1 listing): 2504451RC1
Summary

FSG 59 / FSC 5930

DEMIL: A

DEMIL INT:

HMIC: P

Date Created: 15 Mar 1975

MSDS: None

Hazmat: None

Request a Quote


;



MASTER CROSS REFERENCE LIST (MCRL) | NSN 5930-00-631-3039 Submit RFQ
Manufacturer Part NumberRNCCRNVCManufacturer NameCAGE
2504451RC13 - Design Control Reference2 - Production ItemDETROIT SWITCH, INC.  19278      
Code Definitions

3 - Design Control Reference

Reference Number Category Code (DRN_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

2 - Production Item

Reference Number Variation Code (DRN_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.


FLIS - SEG A - IDENTIFICATION | NSN 5930-00-631-3039 Submit RFQ
FSGFSCNIINFIIGINCCRITICALITYTYPE OF ITEMMRCDEMILHMICEDCPMICADPECDATE CREATED
595930006313039A048B000206X43APU15 Mar 1975
Code Definitions

59

Federal Supply Group (FSG_3994/FSC_WI_FSG_3996)


Electrical and Electronic Equipment Components

5930

Federal Supply Class (FSC_3994/FSC_WI_FSC_3996)


Switches

006313039

National Item Identification Number (NCB_CD_4130/I_I_NBR_4131)


NSN 5930-00-631-3039

A048B0

Federal Item Identification Guide (FIIG_4065)

00206

Item Naming Code (INC_4080)

15 Mar 1975

NIIN Assignment Date (DT_NIIN_ASGMT_2180)

X

Item Criticality (CRITL_CD_FIIG_3843)


The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.

4

Type of Item Identification (TYP_II_4820)


Partial Descriptive Item Identification (Type 1 Concept)

3

Reference / Partial Descriptive Method Reason Code (RPDMRC_4765)


An approved item name and FIIG exist but the item involved is so unique in design that it cannot be fully described in accordance with the FIIG.

A

Demilitarization Code (DEMIL_CD_0167)


Non-MLI/ Non-SLI — Demilitarization not required.

P

Hazardous Material Indicator Code (HMIC_0865)


Indicates there is no information in the HMIRS; however, the NSN is in a FSC in Table II of Federal Standard 313 and a MSDS may be required by the user. The requirement for a MSDS is dependent on a hazard determination of the supplier or the intended end use of the product.

U

Precious Metals Indicator Code (PMIC_0802)


Precious Metal Content is unknown.


FLIS - SEG B - MOE RULE DATA | NSN 5930-00-631-3039 Submit RFQ
MOE RuleFormer MOEAMCAMSCNIMSCIMCIMC ActivityAACDSORCollaboratorsReceiversEffective Date
G90000L1 Apr 1991
Code Definitions

0

Acquisition Method Code (AMC_2871)


Not Established

L

Acquisition Advice Code (AAC_2507)


LOCAL PURCHASE (NON-STOCKED ITEMS) Defense Logistics Agency (DLA)/GSA/Service/Agency-managed items authorized for local purchase as normal means of support at base, post, camp or station level. Item not stocked in wholesale distribution system of IMM/Service/Agency ICP.


FLIS - SEG C - REFERENCE NUMBER | NSN 5930-00-631-3039 Submit RFQ
RNFCRNCCRNVCDACRNAACRNSCRNJCSADCMSDSHCCReference NumberCAGE
332475D2504451RC1  19278  
Code Definitions

3

Reference Number Format Code (RNFC_2920)


Number format is unknown. (Coded RNFC 3 by the Defense Logistics Information Service upon implementation of FLIS.)

3

Reference Number Category Code (RNCC_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

2

Reference Number Variation Code (RNVC_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.

4

Document Availability Code (DAC_2640)


The reference number is represented by technical documentation other than a drawing and the documentation was available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number; however, the RNAAC cannot furnish the technical documentation.

75

Reference Number Action Activity Code (RNAAC_2900)


GSA, FSS/FCSC Washington, DC 20406

D

Reference Number Status Code (RNSC_2923)


Procurement authority of the manufacturer and reference number have not yet been checked. NOTE: This code is to be allocated to reference numbers still requiring checks on procurement authority.


FLIS - SEG E - ITEM STANDARDIZATION DATA | NSN 5930-00-631-3039 Submit RFQ
ISCOriginatorNIIN StatusReplaced / Replacement ISCReplaced / Replacement OriginatorReplacement NIIN StatusReplacement DateReplaced / Replacement NSNDecision Date
2TX031 Mar 1975
Code Definitions

2

Item Standardization Code (ISC_2650)


An item authorized for procurement which has been included in an item reduction study and which initially does not replace an item not authorized for procurement. In addition, in generic relationships, a code 2 item is related to a code 1 item.

TX

Originator of Standardization Decision (ORG_STDZN_DEC_9325)


Defense Supply Center Columbus, Columbus, OH 43218

0

NIIN Status Code (NIIN_STAT_CD_2670)


Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.

31 Mar 1975

Standardization Decision Date (DT_STDZN_DEC_2300)


FLIS - SEG G - FREIGHT DATA | NSN 5930-00-631-3039 Submit RFQ
IntegrityOriginatingHMCLCLWCCTCCSHCADCACCASHLTLNMFCNMFC Sub ItemUFCFreight DescriptionRail Variance
90
Code Definitions

90

Originating Activity Code (ORIG_ACTY_CD_4210)


Tennessee Valley Authority, Chattanooga, TN 37402-2801

Rail Variance

Rail Variance (RAIL_VARI_CD_4760)


No Variation. NMFC and UFCC Match.


FLIS - SEG M/V - CHARACTERISTICS DATA | NSN 5930-00-631-3039 Submit RFQ
MRCDecoded RequirementClear Text Reply
ADAUBody Height3.875 INCHES NOMINAL
ADAQBody Length4.750 INCHES NOMINAL
CTYSContact Adjustment TypeINTERNAL DEACTUATION POINT SCREW WITH SCALE
CQGBContact Action StimulusDECREASE
CTYCContact AdjustabilityDEACTUATION POINT ADJUSTABLE AND ACTUATION POINT NOT ADJUSTABLE
CTYMContact Adjustment Range+0.10/+4.50 DEACTUATION POINT POUNDS PER SQUARE INCH
CTHFContact Load Current Rating16.0 AMPERES MOTOR LOAD FIRST VOLTAGE
CTHFContact Load Current Rating2.0 AMPERES MOTOR LOAD EIGHTH VOLTAGE
CTHFContact Load Current Rating2.5 AMPERES MOTOR LOAD SEVENTH VOLTAGE
CTHFContact Load Current Rating9.6 AMPERES MOTOR LOAD FIFTH VOLTAGE
CTHFContact Load Current Rating3.2 AMPERES MOTOR LOAD FOURTH VOLTAGE
CTHFContact Load Current Rating4.0 AMPERES MOTOR LOAD THIRD VOLTAGE
CTHFContact Load Current Rating4.8 AMPERES MOTOR LOAD SIXTH VOLTAGE
CTHFContact Load Current Rating6.0 AMPERES MOTOR LOAD SECOND VOLTAGE
CTYXContact Stimulus Rating0.06 ACTUATION POINT MINIMUM POUNDS PER SQUARE INCH AND 4.50 ACTUATION POINT MAXIMUM POUNDS PER SQUARE INCH
CTZBContact Voltage Rating In Volts115.0 DC AT SEA LEVEL EIGHTH VOLTAGE
CTZBContact Voltage Rating In Volts115.0 AC AT SEA LEVEL FOURTH VOLTAGE
CTZBContact Voltage Rating In Volts230.0 AC AT SEA LEVEL THIRD VOLTAGE
CTZBContact Voltage Rating In Volts230.0 DC AT SEA LEVEL SEVENTH VOLTAGE
CTZBContact Voltage Rating In Volts440.0 DC AT SEA LEVEL SIXTH VOLTAGE
CTZBContact Voltage Rating In Volts440.0 AC AT SEA LEVEL SECOND VOLTAGE
CTZBContact Voltage Rating In Volts550.0 AC AT SEA LEVEL FIRST VOLTAGE
CTZBContact Voltage Rating In Volts550.0 DC AT SEA LEVEL FIFTH VOLTAGE
AEJNDistance Between Mounting Facility Centers2.250 INCHES NOMINAL
CBBLFeatures ProvidedELECTRICAL ACCESS PORT
FREQFrequency In Hertz60.0 FIRST VOLTAGE
FREQFrequency In Hertz60.0 FOURTH VOLTAGE
FREQFrequency In Hertz60.0 SECOND VOLTAGE
FREQFrequency In Hertz60.0 THIRD VOLTAGE
MEDAMedia For Which DesignedGAS OR LIQUID
CQYJMounting Facility PatternTWO POSITION IN-LINE
AXGYMounting MethodBRACKET
CRLDNonpile-Up Contact Arrangement1 POLE, SINGLE THROW, NORMALLY OPEN, MOMENTARY ACTION
AWTNOperating Temp Rating-30.0 DEG FAHRENHEIT MINIMUM AND 300.0 DEG FAHRENHEIT MAXIMUM
ABKVOutside Diameter1.687 INCHES NOMINAL SINGLE CONNECTION
STYLStyle DesignatorRECTANGULAR
CTZLPressure Connector TypePLAIN, THREADED INTERNAL SINGLE CONNECTION
CQJBProof Pressure20.00 POUNDS PER SQUARE INCH
ABMKOverall Width2.093 INCHES NOMINAL
CSCFTerminal TypeSCREW


Back to Top
Back to Top