5930-00-674-4670

SWITCH,ROTARY


5930-00-674-4670 (5930006744670, 006744670)
Part Numbers (4 listings): 79F908552-3 | 55082 | 34030 | 30035 |
Summary

FSG 59 / FSC 5930

DEMIL: A

DEMIL INT:

HMIC: P

Date Created: 1 Jan 1963

Unit Weight: None

Unit Size: None

Unit Pack Cube: None

MSDS: None

Hazmat: None

Request a Quote


;



MASTER CROSS REFERENCE LIST (MCRL) | NSN 5930-00-674-4670 Submit RFQ
Manufacturer Part NumberRNCCRNVCManufacturer NameCAGE
79F908552-33 - Design Control Reference2 - Production ItemNORTHROP GRUMMAN SYSTEMS CORPORATION  26512    CAGE 26512  
550825 - Replaced / Discontinued2 - Production ItemCONTINENTAL MICROWAVE AND TOOL CO.,  66544    CAGE 66544  
340305 - Replaced / Discontinued2 - Production ItemSTACO ENERGY PRODUCTS CO.  83008      
300355 - Replaced / Discontinued2 - Production ItemSTACO ENERGY PRODUCTS CO.  83008      
550825 - Replaced / Discontinued9 - No Longer UsedLITTON SYSTEMS INC  80006    CAGE 80006  
550825 - Replaced / Discontinued9 - No Longer UsedATLANTIC MICROWAVE CORPORATION  28916      
Code Definitions

3 - Design Control Reference

Reference Number Category Code (DRN_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

5 - Replaced / Discontinued

Reference Number Category Code (DRN_2910)


Secondary Reference. Any additional number, other than a primary number (codes 1,2,3,4) informative reference (code 6) or vendor item drawing reference (code 7) assigned to an item of production or supply by a commercial or Government organization, which represents the same item of production or supply to which the National Stock Number (NSN) was assigned. The reference number may have had an RNCC of 1, 2, 3, 4 or 7 but has since been replaced in the item-of-supply concept of the NSN by another primary number.

2 - Production Item

Reference Number Variation Code (DRN_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.

9 - No Longer Used

Reference Number Variation Code (DRN_4780)


A specification, standard, or other reference number which is superseded, canceled, obsolete or discontinued and is coded Reference Number Category Code (RNCC) 5; a reference number for information only coded RNCC 6; or a reference number coded RNCC D.


FLIS - SEG A - IDENTIFICATION | NSN 5930-00-674-4670 Submit RFQ
FSGFSCNIINFIIGINCCRITICALITYTYPE OF ITEMMRCDEMILHMICEDCPMICADPECDATE CREATED
595930006744670A052B002134X1APU1 Jan 1963
Code Definitions

59

Federal Supply Group (FSG_3994/FSC_WI_FSG_3996)


Electrical and Electronic Equipment Components

5930

Federal Supply Class (FSC_3994/FSC_WI_FSC_3996)


Switches

006744670

National Item Identification Number (NCB_CD_4130/I_I_NBR_4131)


NSN 5930-00-674-4670

A052B0

Federal Item Identification Guide (FIIG_4065)

02134

Item Naming Code (INC_4080)

1 Jan 1963

NIIN Assignment Date (DT_NIIN_ASGMT_2180)

X

Item Criticality (CRITL_CD_FIIG_3843)


The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.

1

Type of Item Identification (TYP_II_4820)


Full Descriptive Item Identification

A

Demilitarization Code (DEMIL_CD_0167)


Non-MLI/ Non-SLI — Demilitarization not required.

P

Hazardous Material Indicator Code (HMIC_0865)


Indicates there is no information in the HMIRS; however, the NSN is in a FSC in Table II of Federal Standard 313 and a MSDS may be required by the user. The requirement for a MSDS is dependent on a hazard determination of the supplier or the intended end use of the product.

U

Precious Metals Indicator Code (PMIC_0802)


Precious Metal Content is unknown.


FLIS - SEG B - MOE RULE DATA | NSN 5930-00-674-4670 Submit RFQ
MOE RuleFormer MOEAMCAMSCNIMSCIMCIMC ActivityAACDSORCollaboratorsReceiversEffective Date
YB011 Apr 1991
Code Definitions

FLIS - SEG C - REFERENCE NUMBER | NSN 5930-00-674-4670 Submit RFQ
RNFCRNCCRNVCDACRNAACRNSCRNJCSADCMSDSHCCReference NumberCAGE
321TXD79F908552-3  26512   CAGE/26512
525ZZ55082  66544   CAGE/66544
3525TXD30035  83008  
3525TXD34030  83008  
3595TXD55082  80006   CAGE/80006
595ZZ55082  28916  
Code Definitions

3

Reference Number Category Code (RNCC_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

2

Reference Number Variation Code (RNVC_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.

1

Document Availability Code (DAC_2640)


The reference number is represented by a drawing and the drawing was available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number. The RNAAC will furnish the drawing upon request.

TX

Reference Number Action Activity Code (RNAAC_2900)


Defense Supply Center Columbus, Columbus, OH 43218

D

Reference Number Status Code (RNSC_2923)


Procurement authority of the manufacturer and reference number have not yet been checked. NOTE: This code is to be allocated to reference numbers still requiring checks on procurement authority.

5

Reference Number Category Code (RNCC_2910)


Secondary Reference. Any additional number, other than a primary number (codes 1,2,3,4) informative reference (code 6) or vendor item drawing reference (code 7) assigned to an item of production or supply by a commercial or Government organization, which represents the same item of production or supply to which the National Stock Number (NSN) was assigned. The reference number may have had an RNCC of 1, 2, 3, 4 or 7 but has since been replaced in the item-of-supply concept of the NSN by another primary number.

5

Document Availability Code (DAC_2640)


The reference number is represented by a drawing, but the drawing was not available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number.

ZZ

Reference Number Action Activity Code (RNAAC_2900)


USA

3

Reference Number Format Code (RNFC_2920)


Number format is unknown. (Coded RNFC 3 by the Defense Logistics Information Service upon implementation of FLIS.)

9

Reference Number Variation Code (RNVC_4780)


A specification, standard, or other reference number which is superseded, canceled, obsolete or discontinued and is coded Reference Number Category Code (RNCC) 5; a reference number for information only coded RNCC 6; or a reference number coded RNCC D.


FLIS - SEG E - ITEM STANDARDIZATION DATA | NSN 5930-00-674-4670 Submit RFQ
ISCOriginatorNIIN StatusReplaced / Replacement ISCReplaced / Replacement OriginatorReplacement NIIN StatusReplacement DateReplaced / Replacement NSNDecision Date
2TX015 Dec 1974
Code Definitions

2

Item Standardization Code (ISC_2650)


An item authorized for procurement which has been included in an item reduction study and which initially does not replace an item not authorized for procurement. In addition, in generic relationships, a code 2 item is related to a code 1 item.

TX

Originator of Standardization Decision (ORG_STDZN_DEC_9325)


Defense Supply Center Columbus, Columbus, OH 43218

0

NIIN Status Code (NIIN_STAT_CD_2670)


Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.

15 Dec 1974

Standardization Decision Date (DT_STDZN_DEC_2300)


FLIS - SEG G - FREIGHT DATA | NSN 5930-00-674-4670 Submit RFQ
IntegrityOriginatingHMCLCLWCCTCCSHCADCACCASHLTLNMFCNMFC Sub ItemUFCFreight DescriptionRail Variance
658Z9AHZP061300X34410CIRCUIT-BREAKER-SWITCH-NOI
Code Definitions

XX

Originating Activity Code (ORIG_ACTY_CD_4210)


658

Water Commodity Code (WRT_CMDTY_CD_9275)


Electical Appliances, Small

Z

Type Cargo Code (TYPE_CGO_CD_9260)


No special type of cargo code applicable

9

Special Handling Code (SP_HDLG_CD_9240)


No special handling required

A

Air Dimension Code (AIR_DIM_CD_9220)


Shipment is not a consolidation and does not exceed 72 inches in any dimension.

H

Air Commodity Code (AIR_CMTY_HDLG_9215)


Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.

Z

Air Special Handling Code (AIR_CMTY_HDLG_9215)


No special handling required.

P

Less Than Truckload (CLAS_RTNG_CD_2770)


77.5

061300

National Motor Freight Classification Number (NMFC Item Number) (NMFC_2850)

X

NMFC Sub Item Number (SUB_ITM_NBR_0861)

34410

Uniform Freight Classification (UFC_CD_MODF_3040)

CIRCUIT-BREAKER-SWITCH-NOI

Freight Description (FRT_DESC_4020)

Rail Variance

Rail Variance (RAIL_VARI_CD_4760)


No Variation. NMFC and UFCC Match.


FLIS - SEG W - PACKAGING DATA | NSN 5930-00-674-4670 Submit RFQ
SourcePICA / SICAPackaging CategoryStoragePreservationClean/DryINT QtyUnit WeightUnit SizeUnit Pack CubeItem WeightItem Dims
PP411AAA
Preservation MaterialWrapping MaterialCushioning / DunnageCushioning ThicknessUnit ContainerIntermediate ContainerUnit Container LevelSpecial MarkingLevel A PackingLevel B PackingMinimal PackingOptional Procedure
00FA000D1DO00QQO
Code Definitions

P

Packaging Data Source Code (PK_DTA_SRC_CD_5148)


Primary Inventory Control Activity (PICA)

P

Primary / Secondary Inventory Control Code (PICA_SICA_IND_5099)


Primary Inventory Control Activity (PICA)

41

Method of Preservation Code (MTHD_PRSRV_CD_5160)


Watervaporproof bag, sealed

1

Cleaning and Drying Procedure Code (CLNG_DRY_PRC_5161)


Any suitable process that is not injurious to the item.

AAA

Intermediate Container Quantity (INTMD_CTN_QTY_5152)

Unit Pack Weight (UP_WT_5153)

Unit Pack Cube (UP_CU_5155)

00

Preservation Material Code (PRSRV_MAT_CD_5162)


No requirement

FA

Wrapping Material Code (WRAP_MAT_CD_5163)


MIL-P-130, laminated and creped wrapping paper

00

Cushioning and Dunnage Material Code (CUSH_DUN_MAT_5164)


No requirement

0

Thickness of Cushioning or Dunnage Code (THK_CUSH_DUN_5165)


Not Applicable

D1

Unit Container Code (UNIT_CTNR_CD_5166)


PPP-B-566 or PPP-B-676, folding or setup box.

DO

Intermediate Container Code (INTMD_CTNR_CD_5167)


Any suitable fiber box included in this table may be used (see J.4.9.1).

00

Special Marking Code (SP_MKG_CD_5169)


No special marking

Q

Packing Requirement Code - For Level A (Maximum) Packing (LVL_A_PKG_CD_5170)


Packing shall be accomplished in accordance with table C.II for the packing level specified. Closure sealing and reinforcement shall be in accordance with applicable specification for shipping container.

Q

Packing Requirement Code - For Level B (Intermediate) Packing (LVL_B_PKG_CD_5171)


Packing shall be accomplished in accordance with table C-II for the packing level specified. Closure sealing and reinforcement shall be in accordance with the appropriate shipping container specification.

O

Optional Procedure Indicator Code (OPTNL_PRO_IND_5173)


Options can be exercised as to specific method of preservation or DoD approved packaging materials to be used. However, basic preservation method shall be retained, supplemental data shall be complied with, and unit package dimensions shall not be increased by more than one inch. Equal or better protection shall be given the item and there shall be no increase in the package cost.


FLIS - SEG M/V - CHARACTERISTICS DATA | NSN 5930-00-674-4670 Submit RFQ
MRCDecoded RequirementClear Text Reply
CTHFContact Load Current Rating5.0 AMPERES RESISTIVE LOAD AC AT SEA LEVEL
CTHFContact Load Current Rating5.0 AMPERES RESISTIVE LOAD DC AT SEA LEVEL AND 5.0 AMPERES INDUCTIVE LOAD DC AT SEA LEVEL
CSHWContact Switching ActionMAKES BEFORE BREAKS EACH SECTION REAR
CQMKContact Voltage Rating In Volts115.0 AC AT SEA LEVEL
CQMKContact Voltage Rating In Volts28.0 DC AT SEA LEVEL
ABNBFirst Flat Length0.440 INCHES NOMINAL SINGLE ACTUATOR
ABNCFlat Height0.216 INCHES NOMINAL SINGLE ACTUATOR
AXGYMounting MethodTHREADED BUSHING SINGLE MOUNTING FACILITY
CQJXNominal Thread Size0.375 INCHES SINGLE MOUNTING FACILITY
AEFPNonturn Device Radius0.375 INCHES NOMINAL AT 6:00 O'CLOCK
AFDCNonturn Device TypePIN AT 6:00 O'CLOCK
AFBHIndividual Section Quantity6
AKPXPole Quantity1 EACH SECTION REAR
ABWVShaft Diameter0.250 INCHES NOMINAL SINGLE ACTUATOR
CRSJShaft TypeROUND, FLATTED SINGLE ACTUATOR
ABXFShaft Length0.620 INCHES NOMINAL SINGLE ACTUATOR
ADAVOverall Diameter1.900 INCHES MAXIMUM
ABHPOverall Length4.200 INCHES NOMINAL
STYLStyle DesignatorTAP, CIRCULAR, BUSHING MOUNT
CRJHSwitch Actuator Indexing Position Quantity8 SINGLE ACTUATOR
CSLCSwitch Actuator Positioning Increment45.0 DEGREES SINGLE ACTUATOR
AJZESwitch Contact Basic DesignNONPILE-UP SYMMETRICAL
CSCFTerminal TypeTAB, SOLDER LUG
AAJDThread Class2A SINGLE MOUNTING FACILITY
AASAThread Length0.380 INCHES NOMINAL SINGLE MOUNTING FACILITY
THSDThread Series DesignatorUNEF SINGLE MOUNTING FACILITY
AKPYThrow Quantity8 EACH SECTION REAR