5930-00-755-5843

SWITCH,ROTARY


5930-00-755-5843 (5930007555843, 007555843)
Part Numbers (5 listings): 8205AKA | 288A886DC | 11K3463PC32 | H544CPC48 | 11K3459ABPC6 |
Summary

FSG 59 / FSC 5930

DEMIL: B

DEMIL INT:

HMIC: P

Date Created: 1 Jan 1962

Unit Weight: 3.6 lbs

Unit Size: 7in x 5in x 5in

Unit Pack Cube: 0.115 cu ft

MSDS: None

Hazmat: None

Request a Quote


;



MASTER CROSS REFERENCE LIST (MCRL) | NSN 5930-00-755-5843 Submit RFQ
Manufacturer Part NumberRNCCRNVCManufacturer NameCAGE
8205AKA3 - Design Control Reference1 - Incomplete Part NumberELECTRO SWITCH CORP.  82121    CAGE 82121  
288A886DC5 - Replaced / Discontinued1 - Incomplete Part NumberGENERAL ELECTRIC CO  24446    CAGE 24446  
11K3463PC325 - Replaced / Discontinued1 - Incomplete Part NumberGENERAL ELECTRIC CO  24446    CAGE 24446  
H544CPC485 - Replaced / Discontinued1 - Incomplete Part NumberWHITMOR COMPANY, INC., THE  92772      
11K3459AB PC65 - Replaced / Discontinued1 - Incomplete Part NumberBECHTEL TECHNICAL SERVICES INC  24374      
Code Definitions

3 - Design Control Reference

Reference Number Category Code (DRN_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

5 - Replaced / Discontinued

Reference Number Category Code (DRN_2910)


Secondary Reference. Any additional number, other than a primary number (codes 1,2,3,4) informative reference (code 6) or vendor item drawing reference (code 7) assigned to an item of production or supply by a commercial or Government organization, which represents the same item of production or supply to which the National Stock Number (NSN) was assigned. The reference number may have had an RNCC of 1, 2, 3, 4 or 7 but has since been replaced in the item-of-supply concept of the NSN by another primary number.

1 - Incomplete Part Number

Reference Number Variation Code (DRN_4780)


A design control or other reference number that does NOT identify an item of production without the use of additional information, or a specific part, type, or similar reference number does NOT identify or item of supply without the use of additional information.


FLIS - SEG A - IDENTIFICATION | NSN 5930-00-755-5843 Submit RFQ
FSGFSCNIINFIIGINCCRITICALITYTYPE OF ITEMMRCDEMILHMICEDCPMICADPECDATE CREATED
595930007555843A052B002134XN9BPA01 Jan 1962
Code Definitions

59

Federal Supply Group (FSG_3994/FSC_WI_FSG_3996)


Electrical and Electronic Equipment Components

5930

Federal Supply Class (FSC_3994/FSC_WI_FSC_3996)


Switches

007555843

National Item Identification Number (NCB_CD_4130/I_I_NBR_4131)


NSN 5930-00-755-5843

A052B0

Federal Item Identification Guide (FIIG_4065)

02134

Item Naming Code (INC_4080)

1 Jan 1962

NIIN Assignment Date (DT_NIIN_ASGMT_2180)

X

Item Criticality (CRITL_CD_FIIG_3843)


The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.

N

Type of Item Identification (TYP_II_4820)


Partial Descriptive - Reference - Descriptive Item Identification (Type 1B Concept)

9

Reference / Partial Descriptive Method Reason Code (RPDMRC_4765)


A Defense Logistics Information Service-generated code for items lacking but requiring an RPDMRC (i.e., through mass FIIG revision change an item may be downgraded from a type 1 to a reference or partial descriptive method item identification).

B

Demilitarization Code (DEMIL_CD_0167)


MLI (Non-Significant Military Equipment – Non-SME) — Demilitarization not required — Trade Security Controls (TSCs) required at disposition.

P

Hazardous Material Indicator Code (HMIC_0865)


Indicates there is no information in the HMIRS; however, the NSN is in a FSC in Table II of Federal Standard 313 and a MSDS may be required by the user. The requirement for a MSDS is dependent on a hazard determination of the supplier or the intended end use of the product.

A

Precious Metals Indicator Code (PMIC_0802)


Item does not contain Precious Metal.

0

ADPE Identification Code (ADPEC_0801)


Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9)


FLIS - SEG B - MOE RULE DATA | NSN 5930-00-755-5843 Submit RFQ
MOE RuleFormer MOEAMCAMSCNIMSCIMCIMC ActivityAACDSORCollaboratorsReceiversEffective Date
YB011 Apr 1991
Code Definitions

FLIS - SEG C - REFERENCE NUMBER | NSN 5930-00-755-5843 Submit RFQ
RNFCRNCCRNVCDACRNAACRNSCRNJCSADCMSDSHCCReference NumberCAGE
3311HXD8205AKA  82121   CAGE/82121
3511HXDH544CPC48  92772  
51CHX11K3459AB PC6  24374  
3511HXD11K3463PC32  24446   CAGE/24446
3511HXD288A886DC  24446   CAGE/24446
Code Definitions

3

Reference Number Format Code (RNFC_2920)


Number format is unknown. (Coded RNFC 3 by the Defense Logistics Information Service upon implementation of FLIS.)

3

Reference Number Category Code (RNCC_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

1

Reference Number Variation Code (RNVC_4780)


A design control or other reference number that does NOT identify an item of production without the use of additional information, or a specific part, type, or similar reference number does NOT identify or item of supply without the use of additional information.

1

Document Availability Code (DAC_2640)


The reference number is represented by a drawing and the drawing was available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number. The RNAAC will furnish the drawing upon request.

HX

Reference Number Action Activity Code (RNAAC_2900)


Navy ICP, Mechanicsburg, PA 17055-0788

D

Reference Number Status Code (RNSC_2923)


Procurement authority of the manufacturer and reference number have not yet been checked. NOTE: This code is to be allocated to reference numbers still requiring checks on procurement authority.

5

Reference Number Category Code (RNCC_2910)


Secondary Reference. Any additional number, other than a primary number (codes 1,2,3,4) informative reference (code 6) or vendor item drawing reference (code 7) assigned to an item of production or supply by a commercial or Government organization, which represents the same item of production or supply to which the National Stock Number (NSN) was assigned. The reference number may have had an RNCC of 1, 2, 3, 4 or 7 but has since been replaced in the item-of-supply concept of the NSN by another primary number.

C

Document Availability Code (DAC_2640)


The reference number is represented by an engineering drawing. The drawing is available for unlimited use but under the security measures specified for the level of security classification assigned. The drawing will be furnished only to qualified requesters by the activity identified by the RNAAC.


FLIS - SEG E - ITEM STANDARDIZATION DATA | NSN 5930-00-755-5843 Submit RFQ
ISCOriginatorNIIN StatusReplaced / Replacement ISCReplaced / Replacement OriginatorReplacement NIIN StatusReplacement DateReplaced / Replacement NSNDecision Date
6TX07 Jul 1968
Code Definitions

6

Item Standardization Code (ISC_2650)


An item authorized for procurement that is in a specific Federal Supply Class (FSC) or item name grouping consisting primarily of items which are one-of-a-kind; therefore, little or no potential exists for elimination of items through formal item reduction studies.

TX

Originator of Standardization Decision (ORG_STDZN_DEC_9325)


Defense Supply Center Columbus, Columbus, OH 43218

0

NIIN Status Code (NIIN_STAT_CD_2670)


Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.

7 Jul 1968

Standardization Decision Date (DT_STDZN_DEC_2300)


FLIS - SEG G - FREIGHT DATA | NSN 5930-00-755-5843 Submit RFQ
IntegrityOriginatingHMCLCLWCCTCCSHCADCACCASHLTLNMFCNMFC Sub ItemUFCFreight DescriptionRail Variance
P658Z9AHZM061360X34430COILS-YOKES-FOCUS-DEFLECTION-TV
Code Definitions

XX

Originating Activity Code (ORIG_ACTY_CD_4210)


P

Less Than Carload (LCL_CD_2760)


77.5

658

Water Commodity Code (WRT_CMDTY_CD_9275)


Electical Appliances, Small

Z

Type Cargo Code (TYPE_CGO_CD_9260)


No special type of cargo code applicable

9

Special Handling Code (SP_HDLG_CD_9240)


No special handling required

A

Air Dimension Code (AIR_DIM_CD_9220)


Shipment is not a consolidation and does not exceed 72 inches in any dimension.

H

Air Commodity Code (AIR_CMTY_HDLG_9215)


Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.

Z

Air Special Handling Code (AIR_CMTY_HDLG_9215)


No special handling required.

M

Less Than Truckload (CLAS_RTNG_CD_2770)


85

061360

National Motor Freight Classification Number (NMFC Item Number) (NMFC_2850)

X

NMFC Sub Item Number (SUB_ITM_NBR_0861)

34430

Uniform Freight Classification (UFC_CD_MODF_3040)

COILS-YOKES-FOCUS-DEFLECTION-TV

Freight Description (FRT_DESC_4020)

Rail Variance

Rail Variance (RAIL_VARI_CD_4760)


No Variation. NMFC and UFCC Match.


FLIS - SEG H - MANAGEMENT DATA | NSN 5930-00-755-5843 Submit RFQ
Unit PriceMOESOSAACCIICQUPReparabilityUISLC
DNN35V71EA0
DNN35V71MEA0
Code Definitions

N35

Source of Supply (SOS_CD_3690) or Source of Supply Modifier (SOSM_CD_2948)


Naval Inventory Control Point, Mechanicsburg, PA 17055-0788

V

Acquisition Advice Code (AAC_2507)


TERMINAL ITEM. Identifies items in stock, but future procurement is not authorized. Requisitions may continue to be submitted until stocks are exhausted. Preferred item National Stock Number is normally provided by application of the phrase: When Exhausted Use (NSN). Requisitions will be submitted in accordance with IMM/Service requisitioning procedures as applicable.

7

Controlled Item Inventory Code (CIIC_2863)


Non-Sensitive (SRC-N/A) — UNCLASSIFIED AA&E or Items assigned a Demilitarization Code other than A, B, Q or P for which another CIIC is inappropriate. (NOTE: The loss, theft, unlawful 011disposition, and/or recovery of an item with CIIC 7 will be investigated in accordance with DoD 4000.25-2-M and DoD 7200.14–R, Volume 12, Chapter7).

1

Quantity Unit Pack (QUP_6106)


1

EA

Unit of Issue (UI_3050)


Each - A numeric quantity of one item of supply. Do not use if a more specific term applies, such as kit, set, assortment, assembly, group, sheet, plate, strip or length.

0

Shelf Life Code (SLC_2943)


TYPE I or TYPE II (Non-Deteriorative/No Shelf-Life) - An individual item of supply which is determined through an evaluation of technical test data and/or actual experience to be an item with a definite non-extendible period of shelf-life OR An individual item of supply having an assigned shelf-life time period that may be extended after completion of inspection/test/restorative action.

M

Reparability Code (REP_CD_DLA_2934 / REP_CD_CG_0709 / ERRC_CD_AF_2655 / RECOV_CD_MC_2891 / RECOV_CD_AR_2892 / MAT_CTL_NVY_2832)


NAVY: Medium Demand Velocity Items (Consumables)

DN

Service / Agency Code (MOE_CD_2833)


Department of the Navy


FLIS - SEG W - PACKAGING DATA | NSN 5930-00-755-5843 Submit RFQ
SourcePICA / SICAPackaging CategoryStoragePreservationClean/DryINT QtyUnit WeightUnit SizeUnit Pack CubeItem WeightItem Dims
APA10003.6 lbs7in x 5in x 5in0.115 cu ft
Preservation MaterialWrapping MaterialCushioning / DunnageCushioning ThicknessUnit ContainerIntermediate ContainerUnit Container LevelSpecial MarkingLevel A PackingLevel B PackingMinimal PackingOptional Procedure
0000XD300O00EQM
Code Definitions

A

Packaging Data Source Code (PK_DTA_SRC_CD_5148)


Packaging Data Record contains data that does not meet current MIL-STD-2073-1C/D formats

P

Primary / Secondary Inventory Control Code (PICA_SICA_IND_5099)


Primary Inventory Control Activity (PICA)

A

Item Type Storage Code (ITM_TYP_STOR_5156)


Heated General Purpose – Heated 40 F and above

1

Cleaning and Drying Procedure Code (CLNG_DRY_PRC_5161)


Any suitable process that is not injurious to the item.

000

Intermediate Container Quantity (INTMD_CTN_QTY_5152)

3.6 lbs

Unit Pack Weight (UP_WT_5153)

7in x 5in x 5in

Unit Pack Size (UP_SZ_5154)

0.115 cu ft

Unit Pack Cube (UP_CU_5155)

00

Preservation Material Code (PRSRV_MAT_CD_5162)


No requirement

00

Wrapping Material Code (WRAP_MAT_CD_5163)


No requirement

X

Thickness of Cushioning or Dunnage Code (THK_CUSH_DUN_5165)


As required to protect the item or elements of the package

D3

Unit Container Code (UNIT_CTNR_CD_5166)


PPP-B-566, PPP-B-676, or ASTM-D5118, folding, setup or fiberboard box.

00

Intermediate Container Code (INTMD_CTNR_CD_5167)


No requirement.

O

Unit Container Level Code (UNIT_CTNR_LVL_5168)


Unit container is not an acceptable shipping container.

00

Special Marking Code (SP_MKG_CD_5169)


No special marking

E

Packing Requirement Code - For Level A (Maximum) Packing (LVL_A_PKG_CD_5170)


Packing shall be accomplished to meet the performance test requirements of ASTMD4169, Distribution Cycle 18, Assurance Level 1.

Q

Packing Requirement Code - For Level B (Intermediate) Packing (LVL_B_PKG_CD_5171)


Packing shall be accomplished in accordance with table C-II for the packing level specified. Closure sealing and reinforcement shall be in accordance with the appropriate shipping container specification.

M

Optional Procedure Indicator Code (OPTNL_PRO_IND_5173)


All packaging data is mandatory for compliance and no substitutions are permitted. Fast packs should be included in this category.


FLIS - SEG M/V - CHARACTERISTICS DATA | NSN 5930-00-755-5843 Submit RFQ
MRCDecoded RequirementClear Text Reply
CTHFContact Load Current Rating10.0 AMPERES RESISTIVE LOAD AC AT SEA LEVEL
CQMKContact Voltage Rating In Volts125.0 AC AT SEA LEVEL
CSHWContact Switching ActionBREAKS BEFORE MAKES EACH SECTION FRONT
CBBLFeatures ProvidedACTUATOR KNOB
ABNBFirst Flat Length0.500 INCHES NOMINAL SINGLE ACTUATOR
ABNCFlat Height0.312 INCHES NOMINAL SINGLE ACTUATOR
ALAQMounting Facility Circle Radius1.609 INCHES NOMINAL SINGLE MOUNTING FACILITY
CQYJMounting Facility PatternFOUR POSITION CIRCULAR SINGLE MOUNTING FACILITY
CQJXNominal Thread Size0.250 INCHES SINGLE MOUNTING FACILITY
AFBHIndividual Section Quantity8
AFCQKnob Manufacturer Code82121
AFCYKnob Manufacturer Part Number8164-12Y
AKPXPole Quantity1 EACH SECTION FRONT
ZZZYReference Number Differentiating CharacteristicsMATERIAL WILL BE IN ACCORDANCE WITH SHIPS PARTS CONTROL CENTERACTIVITY HX QUALITY CONTROL,MANUFACTURING AND TESTING SPECIFICATIONS
ABWVShaft Diameter0.375 INCHES NOMINAL SINGLE ACTUATOR
CQRQShaft Flat/Slot Angular Location180.0 DEGREES FROM NONTURN DEVICE SINGLE ACTUATOR
CRSJShaft TypeROUND, FLATTED, THREADED HOLE SINGLE ACTUATOR
ABXFShaft Length0.875 INCHES NOMINAL SINGLE ACTUATOR
ABKWOverall Height2.875 INCHES NOMINAL
ABHPOverall Length5.187 INCHES NOMINAL
ABMKOverall Width4.375 INCHES NOMINAL
FEATSpecial FeaturesSHAFT DRILLED PERPINDICULAR TO FLAT AND TAPPED 5-40 0.438 IN.FROM END OF SHAFT FOR PIN STYLE 1 MOUNTING 2 HOLES 0.312 IN. ON3.812 IN. MOUNTING CENTERS
STYLStyle DesignatorTAP, CIRCUIT SELECTOR
CRJHSwitch Actuator Indexing Position Quantity4 SINGLE ACTUATOR
CQQTSwitch Actuator Momentary PositionCLOCKWISE SINGLE ACTUATOR
CSLCSwitch Actuator Positioning Increment90.0 DEGREES SINGLE ACTUATOR
CTDNSwitch Actuator Stop Device TypeADJUSTABLE STOP SINGLE ACTUATOR
AJZESwitch Contact Basic DesignNONPILE-UP SYMMETRICAL
CSCFTerminal TypeTAB W/SCREW
THSDThread Series DesignatorUNC SINGLE MOUNTING FACILITY
CMLPThread Quantity Per Inch20 SINGLE MOUNTING FACILITY
AKPYThrow Quantity3 EACH SECTION FRONT


Back to Top
Back to Top