Manufacturer Part Number | RNCC | RNVC | Manufacturer Name | CAGE | |
---|---|---|---|---|---|
2-1905M-12-6N | 3 - Design Control Reference | 2 - Production Item | JANCO CORPORATION | 91812 | ![]() |
Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.
A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.
FSG | FSC | NIIN | FIIG | INC | CRITICALITY | TYPE OF ITEM | MRC | DEMIL | HMIC | EDC | PMIC | ADPEC | DATE CREATED |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
59 | 5930 | 008304782 | A052B0 | 02134 | X | 1 | A | P | U | 1 Sep 1967 |
The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Full Descriptive Item Identification
Non-MLI/ Non-SLI — Demilitarization not required.
Indicates there is no information in the HMIRS; however, the NSN is in a FSC in Table II of Federal Standard 313 and a MSDS may be required by the user. The requirement for a MSDS is dependent on a hazard determination of the supplier or the intended end use of the product.
Precious Metal Content is unknown.
MOE Rule | Former MOE | AMC | AMSC | NIMSC | IMC | IMC Activity | AAC | DSOR | Collaborators | Receivers | Effective Date | |||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
FXGX | FXTX | 0 | 0 | Z | SX | 1 Nov 2005 |
Not Established
Integrated Management: Relinquishment of Service management of an item in designated commodity oriented Federal Supply Classes to the IMM (FSC manager) for management.
Oklahoma City Air Logistics Center, Tinker AFB, OK 73145-3043
RNFC | RNCC | RNVC | DAC | RNAAC | RNSC | RNJC | SADC | MSDS | HCC | Reference Number | CAGE | |
---|---|---|---|---|---|---|---|---|---|---|---|---|
3 | 2 | 5 | ZZ | 2-1905M-12-6N | 91812 | ![]() |
Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.
A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.
The reference number is represented by a drawing, but the drawing was not available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number.
USA
ISC | Originator | NIIN Status | Replaced / Replacement ISC | Replaced / Replacement Originator | Replacement NIIN Status | Replacement Date | Replaced / Replacement NSN | Decision Date |
---|---|---|---|---|---|---|---|---|
2 | TX | 0 | 28 Dec 1968 |
An item authorized for procurement which has been included in an item reduction study and which initially does not replace an item not authorized for procurement. In addition, in generic relationships, a code 2 item is related to a code 1 item.
Defense Supply Center Columbus, Columbus, OH 43218
Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.
Integrity | Originating | HMC | LCL | WCC | TCC | SHC | ADC | ACC | ASH | LTL | NMFC | NMFC Sub Item | UFC | Freight Description | Rail Variance |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
TX | 72D | Z | 9 | A | H | Z | M | 061360 | X | 34430 | COILS-YOKES-FOCUS-DEFLECTION-TV |
Defense Supply Center Columbus, Columbus, OH 43218
Communications/Electronics, other than SIGINT/EW or COMSEC. Repair Parts and Components
No special type of cargo code applicable
No special handling required
Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
No special handling required.
85
No Variation. NMFC and UFCC Match.
Defense Logistics Agency, Enterprise Business Systems
LOCAL PURCHASE (NON-STOCKED ITEMS) Defense Logistics Agency (DLA)/GSA/Service/Agency-managed items authorized for local purchase as normal means of support at base, post, camp or station level. Item not stocked in wholesale distribution system of IMM/Service/Agency ICP.
Unclassified
1
AIR FORCE ERRC XB3: Stock Fund (Except Munitions); DLA: This item has been reviewed and a determination made that the item cannot or should not be restored to a serviceable condition from an unserviceable condition; NAVY: 1I cog not stocked print on demand flat forms
Each - A numeric quantity of one item of supply. Do not use if a more specific term applies, such as kit, set, assortment, assembly, group, sheet, plate, strip or length.
TYPE I or TYPE II (Non-Deteriorative/No Shelf-Life) - An individual item of supply which is determined through an evaluation of technical test data and/or actual experience to be an item with a definite non-extendible period of shelf-life OR An individual item of supply having an assigned shelf-life time period that may be extended after completion of inspection/test/restorative action.
Department of the Air Force
Defense Logistics Agency
MRC | Decoded Requirement | Clear Text Reply |
---|---|---|
CTHF | Contact Load Current Rating | 1.0 AMPERES RESISTIVE LOAD AC AT SEA LEVEL250.0 MILLIAMPERES INDUCTIVE LOAD DC AT SEA LEVEL AND 500.0 MILLIAMPERES RESISTIVE LOAD DC AT SEA LEVEL |
CQMK | Contact Voltage Rating In Volts | 115.0 AC AT SEA LEVEL28.0 DC AT SEA LEVEL |
CSHW | Contact Switching Action | BREAKS BEFORE MAKES EACH SECTION REAR |
CSMW | Detent Rotational Torque Range | +1.750/+7.000 INCH-POUNDS SINGLE ACTUATOR |
ABNB | First Flat Length | 0.250 INCHES NOMINAL SINGLE ACTUATOR |
ABNC | Flat Height | 0.205 INCHES MINIMUM SINGLE ACTUATOR AND 0.210 INCHES MAXIMUM SINGLE ACTUATOR |
ABFE | Hazardous Locations/Environmental Protection | EXPLOSION PROOF |
AXGY | Mounting Method | THREADED BUSHING SINGLE MOUNTING FACILITY |
CQJX | Nominal Thread Size | 0.375 INCHES SINGLE MOUNTING FACILITY |
AEFP | Nonturn Device Radius | 0.432 INCHES NOMINAL AT 3:00 O'CLOCK |
AFDC | Nonturn Device Type | TAB AT 3:00 O'CLOCK |
AFGA | Operating Temp Range | -65.0/+85.0 DEG CELSIUS |
AFBH | Individual Section Quantity | 12 |
AKPX | Pole Quantity | 1 EACH SECTION FRONT |
CQTH | Rotor Through Connection Quantity | 1 EACH SECTION |
ABWV | Shaft Diameter | 0.248 INCHES MINIMUM SINGLE ACTUATOR AND 0.252 INCHES MAXIMUM SINGLE ACTUATOR |
ABXF | Shaft Length | 0.370 INCHES NOMINAL SINGLE ACTUATOR |
CRSJ | Shaft Type | ROUND, FLATTED SINGLE ACTUATOR |
ADAV | Overall Diameter | 1.100 INCHES NOMINAL |
ABHP | Overall Length | 5.510 INCHES NOMINAL |
STYL | Style Designator | TAP, CIRCULAR, BUSHING MOUNT |
CRJH | Switch Actuator Indexing Position Quantity | 6 SINGLE ACTUATOR |
CSLC | Switch Actuator Positioning Increment | 30.0 DEGREES SINGLE ACTUATOR |
CTDN | Switch Actuator Stop Device Type | FIXED STOP SINGLE ACTUATOR |
AJZE | Switch Contact Basic Design | NONPILE-UP SYMMETRICAL |
CSCF | Terminal Type | TAB, SOLDER LUG |
AAJD | Thread Class | 2A SINGLE MOUNTING FACILITY |
AASA | Thread Length | 0.430 INCHES NOMINAL SINGLE MOUNTING FACILITY |
THSD | Thread Series Designator | UNEF SINGLE MOUNTING FACILITY |
AKPY | Throw Quantity | 6 EACH SECTION REAR |