5930-00-835-0707

SWITCH,PUSH


5930-00-835-0707 (5930008350707, 008350707)
Part Numbers (4 listings): 1125L30W4 | 1125L30W4P | 5679-1 | DMS80058B |
Summary

FSG 59 / FSC 5930

DEMIL: A

DEMIL INT:

HMIC: P

Date Created: 30 Nov 1966

Unit Weight: 0.2 lbs

Unit Size:

Unit Pack Cube: 0.009 cu ft

MSDS: None

Hazmat: None

Request a Quote


;



MASTER CROSS REFERENCE LIST (MCRL) | NSN 5930-00-835-0707 Submit RFQ
Manufacturer Part NumberRNCCRNVCManufacturer NameCAGE
1125L30W43 - Design Control Reference2 - Production ItemELECTRO-MECH COMPONENTS, INC.  07150    CAGE 07150  
1125L30W4P5 - Replaced / Discontinued2 - Production ItemELECTRO-MECH COMPONENTS, INC.  07150    CAGE 07150  
5679-15 - Replaced / Discontinued2 - Production ItemRAYTHEON COMPANY  05869    CAGE 05869  
1125L30W45 - Replaced / Discontinued9 - No Longer UsedPOLLAK CORP  97564    CAGE 97564  
1125L30W4P5 - Replaced / Discontinued9 - No Longer UsedPOLLAK CORP  97564    CAGE 97564  
DMS 80058B5 - Replaced / Discontinued9 - No Longer UsedDLA LAND AND MARITIME  16236    CAGE 16236  
Code Definitions

3 - Design Control Reference

Reference Number Category Code (DRN_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

5 - Replaced / Discontinued

Reference Number Category Code (DRN_2910)


Secondary Reference. Any additional number, other than a primary number (codes 1,2,3,4) informative reference (code 6) or vendor item drawing reference (code 7) assigned to an item of production or supply by a commercial or Government organization, which represents the same item of production or supply to which the National Stock Number (NSN) was assigned. The reference number may have had an RNCC of 1, 2, 3, 4 or 7 but has since been replaced in the item-of-supply concept of the NSN by another primary number.

2 - Production Item

Reference Number Variation Code (DRN_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.

9 - No Longer Used

Reference Number Variation Code (DRN_4780)


A specification, standard, or other reference number which is superseded, canceled, obsolete or discontinued and is coded Reference Number Category Code (RNCC) 5; a reference number for information only coded RNCC 6; or a reference number coded RNCC D.


FLIS - SEG A - IDENTIFICATION | NSN 5930-00-835-0707 Submit RFQ
FSGFSCNIINFIIGINCCRITICALITYTYPE OF ITEMMRCDEMILHMICEDCPMICADPECDATE CREATED
595930008350707A053A000406XM3APU30 Nov 1966
Code Definitions

59

Federal Supply Group (FSG_3994/FSC_WI_FSG_3996)


Electrical and Electronic Equipment Components

5930

Federal Supply Class (FSC_3994/FSC_WI_FSC_3996)


Switches

008350707

National Item Identification Number (NCB_CD_4130/I_I_NBR_4131)


NSN 5930-00-835-0707

A053A0

Federal Item Identification Guide (FIIG_4065)

00406

Item Naming Code (INC_4080)

30 Nov 1966

NIIN Assignment Date (DT_NIIN_ASGMT_2180)

X

Item Criticality (CRITL_CD_FIIG_3843)


The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.

M

Type of Item Identification (TYP_II_4820)


Partial Descriptive - Reference Item Identification (Type 1A Concept)

3

Reference / Partial Descriptive Method Reason Code (RPDMRC_4765)


An approved item name and FIIG exist but the item involved is so unique in design that it cannot be fully described in accordance with the FIIG.

A

Demilitarization Code (DEMIL_CD_0167)


Non-MLI/ Non-SLI — Demilitarization not required.

P

Hazardous Material Indicator Code (HMIC_0865)


Indicates there is no information in the HMIRS; however, the NSN is in a FSC in Table II of Federal Standard 313 and a MSDS may be required by the user. The requirement for a MSDS is dependent on a hazard determination of the supplier or the intended end use of the product.

U

Precious Metals Indicator Code (PMIC_0802)


Precious Metal Content is unknown.


FLIS - SEG B - MOE RULE DATA | NSN 5930-00-835-0707 Submit RFQ
MOE RuleFormer MOEAMCAMSCNIMSCIMCIMC ActivityAACDSORCollaboratorsReceiversEffective Date
ZN011 Apr 1991
ZR011 Apr 1991
ZU011 Apr 1991
ZW011 Apr 1991
Code Definitions

FLIS - SEG C - REFERENCE NUMBER | NSN 5930-00-835-0707 Submit RFQ
RNFCRNCCRNVCDACRNAACRNSCRNJCSADCMSDSHCCReference NumberCAGE
324ZB1125L30W4  07150   CAGE/07150
523TX1125L30W4P  07150   CAGE/07150
3524ZBD5679-1  05869   CAGE/05869
599TXDMS 80058B  16236   CAGE/16236
3594ZBB1125L30W4  97564   CAGE/97564
3593TXB1125L30W4P  97564   CAGE/97564
Code Definitions

3

Reference Number Category Code (RNCC_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

2

Reference Number Variation Code (RNVC_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.

4

Document Availability Code (DAC_2640)


The reference number is represented by technical documentation other than a drawing and the documentation was available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number; however, the RNAAC cannot furnish the technical documentation.

ZB

Reference Number Action Activity Code (RNAAC_2900)


Belgium

5

Reference Number Category Code (RNCC_2910)


Secondary Reference. Any additional number, other than a primary number (codes 1,2,3,4) informative reference (code 6) or vendor item drawing reference (code 7) assigned to an item of production or supply by a commercial or Government organization, which represents the same item of production or supply to which the National Stock Number (NSN) was assigned. The reference number may have had an RNCC of 1, 2, 3, 4 or 7 but has since been replaced in the item-of-supply concept of the NSN by another primary number.

3

Document Availability Code (DAC_2640)


The reference number is represented by technical documentation other than a drawing and the documentation was available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number. The RNAAC will furnish the technical documentation upon request.

TX

Reference Number Action Activity Code (RNAAC_2900)


Defense Supply Center Columbus, Columbus, OH 43218

3

Reference Number Format Code (RNFC_2920)


Number format is unknown. (Coded RNFC 3 by the Defense Logistics Information Service upon implementation of FLIS.)

D

Reference Number Status Code (RNSC_2923)


Procurement authority of the manufacturer and reference number have not yet been checked. NOTE: This code is to be allocated to reference numbers still requiring checks on procurement authority.

9

Reference Number Variation Code (RNVC_4780)


A specification, standard, or other reference number which is superseded, canceled, obsolete or discontinued and is coded Reference Number Category Code (RNCC) 5; a reference number for information only coded RNCC 6; or a reference number coded RNCC D.

9

Document Availability Code (DAC_2640)


The reference number is of the type for which an indication of document availability is not required.

B

Reference Number Status Code (RNSC_2923)


Manufacturer and/or reference number are not authorized for procurement. NOTE: This code may be used for obsolete or informative reference numbers only.


FLIS - SEG E - ITEM STANDARDIZATION DATA | NSN 5930-00-835-0707 Submit RFQ
ISCOriginatorNIIN StatusReplaced / Replacement ISCReplaced / Replacement OriginatorReplacement NIIN StatusReplacement DateReplaced / Replacement NSNDecision Date
2TX021 Sep 1968
Code Definitions

2

Item Standardization Code (ISC_2650)


An item authorized for procurement which has been included in an item reduction study and which initially does not replace an item not authorized for procurement. In addition, in generic relationships, a code 2 item is related to a code 1 item.

TX

Originator of Standardization Decision (ORG_STDZN_DEC_9325)


Defense Supply Center Columbus, Columbus, OH 43218

0

NIIN Status Code (NIIN_STAT_CD_2670)


Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.

21 Sep 1968

Standardization Decision Date (DT_STDZN_DEC_2300)


FLIS - SEG G - FREIGHT DATA | NSN 5930-00-835-0707 Submit RFQ
IntegrityOriginatingHMCLCLWCCTCCSHCADCACCASHLTLNMFCNMFC Sub ItemUFCFreight DescriptionRail Variance
ZB723Z9AHZM061360X34430COILS-YOKES-FOCUS-DEFLECTION-TV
Code Definitions

ZB

Originating Activity Code (ORIG_ACTY_CD_4210)


Belgium

723

Water Commodity Code (WRT_CMDTY_CD_9275)


Radio Parts, Batteries and Equipment, excluding Tubes Packed separately

Z

Type Cargo Code (TYPE_CGO_CD_9260)


No special type of cargo code applicable

9

Special Handling Code (SP_HDLG_CD_9240)


No special handling required

A

Air Dimension Code (AIR_DIM_CD_9220)


Shipment is not a consolidation and does not exceed 72 inches in any dimension.

H

Air Commodity Code (AIR_CMTY_HDLG_9215)


Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.

Z

Air Special Handling Code (AIR_CMTY_HDLG_9215)


No special handling required.

M

Less Than Truckload (CLAS_RTNG_CD_2770)


85

061360

National Motor Freight Classification Number (NMFC Item Number) (NMFC_2850)

X

NMFC Sub Item Number (SUB_ITM_NBR_0861)

34430

Uniform Freight Classification (UFC_CD_MODF_3040)

COILS-YOKES-FOCUS-DEFLECTION-TV

Freight Description (FRT_DESC_4020)

Rail Variance

Rail Variance (RAIL_VARI_CD_4760)


No Variation. NMFC and UFCC Match.


FLIS - SEG W - PACKAGING DATA | NSN 5930-00-835-0707 Submit RFQ
SourcePICA / SICAPackaging CategoryStoragePreservationClean/DryINT QtyUnit WeightUnit SizeUnit Pack CubeItem WeightItem Dims
APAZZZ0.2 lbs0.009 cu ft
Preservation MaterialWrapping MaterialCushioning / DunnageCushioning ThicknessUnit ContainerIntermediate ContainerUnit Container LevelSpecial MarkingLevel A PackingLevel B PackingMinimal PackingOptional Procedure
ZZZZZZZZZZZ
Code Definitions

A

Packaging Data Source Code (PK_DTA_SRC_CD_5148)


Packaging Data Record contains data that does not meet current MIL-STD-2073-1C/D formats

P

Primary / Secondary Inventory Control Code (PICA_SICA_IND_5099)


Primary Inventory Control Activity (PICA)

A

Item Type Storage Code (ITM_TYP_STOR_5156)


Heated General Purpose – Heated 40 F and above

ZZ

Method of Preservation Code (MTHD_PRSRV_CD_5160)


See J.4.1.b

Z

Cleaning and Drying Procedure Code (CLNG_DRY_PRC_5161)


Special Requirements - See specific instructions or drawings provided.

0.2 lbs

Unit Pack Weight (UP_WT_5153)

0.009 cu ft

Unit Pack Cube (UP_CU_5155)

ZZ

Preservation Material Code (PRSRV_MAT_CD_5162)


Special requirement – See specific instructions or drawings provided

ZZ

Wrapping Material Code (WRAP_MAT_CD_5163)


Special requirements – see specific instructions or drawings provided

ZZ

Cushioning and Dunnage Material Code (CUSH_DUN_MAT_5164)


Special requirements. See specific instructions or drawings provided.

Z

Thickness of Cushioning or Dunnage Code (THK_CUSH_DUN_5165)


Special requirements-See specific instructions or drawings provided

ZZ

Unit Container Code (UNIT_CTNR_CD_5166)


Special requirement – See specific instructions or drawings provided.

ZZ

Intermediate Container Code (INTMD_CTNR_CD_5167)


Special requirement – See specific instructions or drawings provided.


FLIS - SEG M/V - CHARACTERISTICS DATA | NSN 5930-00-835-0707 Submit RFQ
MRCDecoded RequirementClear Text Reply
AFUSActuator Height0.380 INCHES NOMINAL
AFVAActuator ColorWHITE SINGLE ACTUATOR
AFURActuator Diameter0.500 INCHES NOMINAL
ABPMBody Diameter0.750 INCHES NOMINAL
ADAQBody Length1.000 INCHES NOMINAL
AAQLBody StyleBUSHING MOUNTED
ABXDBushing Length0.410 INCHES NOMINAL
CXQRContact Load Current Rating At Maximum Rated Voltage2.000 AMPERES RESISTIVE DC AND 2.000 AMPERES RESISTIVE AC
AFXEMaximum Voltage Rating In Volts125.0 AC AND 30.0 DC
AXGYMounting MethodTHREADED BUSHING
CQJXNominal Thread Size0.563 INCHES
CRLDNonpile-Up Contact Arrangement1 POLE, DOUBLE THROW, BOTH POSITIONS MAINTAINED SINGLE SWITCH UNIT
AFVBIlluminated Actuator ColorWHITE SINGLE ACTUATOR
AKNAInclosure TypeFULLY INCLOSED
TTQYTerminal Type And Quantity5 TAB, SOLDER LUG
THSDThread Series DesignatorUN
CMLPThread Quantity Per Inch32


Back to Top