Manufacturer Part Number | RNCC | RNVC | Manufacturer Name | CAGE | |
---|---|---|---|---|---|
228MS193P001 | 3 - Design Control Reference | 2 - Production Item | RAYTHEON ELECTRONIC SYSTEMS, INC | 04164 | ![]() |
228MS193P001 | 5 - Replaced / Discontinued | 2 - Production Item | RAYTHEON COMPANY | 49956 | ![]() |
Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.
Secondary Reference. Any additional number, other than a primary number (codes 1,2,3,4) informative reference (code 6) or vendor item drawing reference (code 7) assigned to an item of production or supply by a commercial or Government organization, which represents the same item of production or supply to which the National Stock Number (NSN) was assigned. The reference number may have had an RNCC of 1, 2, 3, 4 or 7 but has since been replaced in the item-of-supply concept of the NSN by another primary number.
A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.
FSG | FSC | NIIN | FIIG | INC | CRITICALITY | TYPE OF ITEM | MRC | DEMIL | HMIC | EDC | PMIC | ADPEC | DATE CREATED |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
59 | 5930 | 008359945 | A053A0 | 00399 | X | 4 | 3 | A | P | U | 1 Jan 1962 |
The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Partial Descriptive Item Identification (Type 1 Concept)
An approved item name and FIIG exist but the item involved is so unique in design that it cannot be fully described in accordance with the FIIG.
Non-MLI/ Non-SLI — Demilitarization not required.
Indicates there is no information in the HMIRS; however, the NSN is in a FSC in Table II of Federal Standard 313 and a MSDS may be required by the user. The requirement for a MSDS is dependent on a hazard determination of the supplier or the intended end use of the product.
Precious Metal Content is unknown.
MOE Rule | Former MOE | AMC | AMSC | NIMSC | IMC | IMC Activity | AAC | DSOR | Collaborators | Receivers | Effective Date | |||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
N9BN | N9ND | 0 | 0 | Z | KE | KE | 1 Nov 2005 | |||||||||||||||||||||||
YD01 | 1 Aug 2016 |
Not Established
Integrated Management: Relinquishment of Service management of an item in designated commodity oriented Federal Supply Classes to the IMM (FSC manager) for management.
Naval ICP, Philadelphia, PA 19111
Naval ICP, Philadelphia, PA 19111
ISC | Originator | NIIN Status | Replaced / Replacement ISC | Replaced / Replacement Originator | Replacement NIIN Status | Replacement Date | Replaced / Replacement NSN | Decision Date |
---|---|---|---|---|---|---|---|---|
6 | TX | 0 | 28 Mar 1971 |
An item authorized for procurement that is in a specific Federal Supply Class (FSC) or item name grouping consisting primarily of items which are one-of-a-kind; therefore, little or no potential exists for elimination of items through formal item reduction studies.
Defense Supply Center Columbus, Columbus, OH 43218
Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.
Integrity | Originating | HMC | LCL | WCC | TCC | SHC | ADC | ACC | ASH | LTL | NMFC | NMFC Sub Item | UFC | Freight Description | Rail Variance |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
72D | Z | 9 | A | H | Z | M | 061360 | X | 34430 | COILS-YOKES-FOCUS-DEFLECTION-TV |
Communications/Electronics, other than SIGINT/EW or COMSEC. Repair Parts and Components
No special type of cargo code applicable
No special handling required
Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
No special handling required.
85
No Variation. NMFC and UFCC Match.
Defense Logistics Agency, Enterprise Business Systems
NOT STOCKED, CENTRALLY PROCURED # (NON-STOCKED ITEMS) IMM/Service centrally managed but not stocked item. Procurement will be initiated only after receipt of a requisition.
Unclassified
1
Each - A numeric quantity of one item of supply. Do not use if a more specific term applies, such as kit, set, assortment, assembly, group, sheet, plate, strip or length.
TYPE I or TYPE II (Non-Deteriorative/No Shelf-Life) - An individual item of supply which is determined through an evaluation of technical test data and/or actual experience to be an item with a definite non-extendible period of shelf-life OR An individual item of supply having an assigned shelf-life time period that may be extended after completion of inspection/test/restorative action.
Department of the Navy
Defense Logistics Agency
MRC | Decoded Requirement | Clear Text Reply |
---|---|---|
AFUU | Actuator Free Position Height | 0.625 INCHES NOMINAL |
AFUR | Actuator Diameter | 0.093 INCHES NOMINAL |
CXQQ | Actuator Movement | 0.030 PRETRAVEL INCHES MAXIMUM AND 0.005 OVERTRAVEL INCHES MINIMUM AND 0.030 DIFFERENTIAL INCHES MAXIMUM |
AFUQ | Actuator Style | ROUND |
ADAU | Body Height | 0.953 INCHES NOMINAL |
ADAQ | Body Length | 1.938 INCHES NOMINAL |
AAQL | Body Style | HOLE MOUNTED |
ADAT | Body Width | 0.688 INCHES NOMINAL |
ADTV | Case Material | PLASTIC |
ABKQ | Center To Center Distance Between Mounting Facilities Parallel To Length | 1.000 INCHES NOMINAL |
CXQR | Contact Load Current Rating At Maximum Rated Voltage | 25.000 AMPERES RESISTIVE DC AND 10.000 AMPERES INDUCTIVE DC AND 5.000 AMPERES MOTOR DC AND 10.000 AMPERES RESISTIVE AC AND 10.000 AMPERES INDUCTIVE AC AND 5.000 AMPERES MOTOR AC |
AFXE | Maximum Voltage Rating In Volts | 115.0 AC AND 28.0 DC |
AXGY | Mounting Method | UNTHREADED HOLE |
CRLD | Nonpile-Up Contact Arrangement | 1 POLE, DOUBLE THROW, ONE POSITION MOMENTARY SINGLE SWITCH UNIT |
AKNA | Inclosure Type | FULLY INCLOSED |
ABKW | Overall Height | 1.297 INCHES NOMINAL |
ABHP | Overall Length | 1.938 INCHES NOMINAL |
ABMK | Overall Width | 0.688 INCHES NOMINAL |
AEBV | Unthreaded Mounting Hole Diameter | 0.140 INCHES NOMINAL |
CSJN | Switch Actuating Force | 24.0 OUNCES NOMINAL |
TTQY | Terminal Type And Quantity | 3 SCREW |