Manufacturer Part Number | RNCC | RNVC | Manufacturer Name | CAGE | |
---|---|---|---|---|---|
117C526-2 | 3 - Design Control Reference | 2 - Production Item | TELEPHONICS CORPORATION | 78711 | ![]() |
226186J4C | 5 - Replaced / Discontinued | 2 - Production Item | ELECTRO SWITCH CORP. | 76854 | ![]() |
Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.
Secondary Reference. Any additional number, other than a primary number (codes 1,2,3,4) informative reference (code 6) or vendor item drawing reference (code 7) assigned to an item of production or supply by a commercial or Government organization, which represents the same item of production or supply to which the National Stock Number (NSN) was assigned. The reference number may have had an RNCC of 1, 2, 3, 4 or 7 but has since been replaced in the item-of-supply concept of the NSN by another primary number.
A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.
FSG | FSC | NIIN | FIIG | INC | CRITICALITY | TYPE OF ITEM | MRC | DEMIL | HMIC | EDC | PMIC | ADPEC | DATE CREATED |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
59 | 5930 | 008691045 | A052B0 | 02134 | X | K | A | P | U | 1 Jan 1960 |
The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Full Descriptive - Reference Item Identification
Non-MLI/ Non-SLI — Demilitarization not required.
Indicates there is no information in the HMIRS; however, the NSN is in a FSC in Table II of Federal Standard 313 and a MSDS may be required by the user. The requirement for a MSDS is dependent on a hazard determination of the supplier or the intended end use of the product.
Precious Metal Content is unknown.
MOE Rule | Former MOE | AMC | AMSC | NIMSC | IMC | IMC Activity | AAC | DSOR | Collaborators | Receivers | Effective Date | |||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
N9BN | N9ND | 3 | R | Z | GH | GT | KE | 1 Nov 2005 |
Acquire directly from the actual manufacturer, whether or not the prime contractor is the actual manufacturer.
The data or the rights to use the data needed to purchase this part from additional sources are not owned by the Government and it has been determined that it is uneconomical to purchase them. Valid AMCs: 1, 2, 3, 4 and 5.
Integrated Management: Relinquishment of Service management of an item in designated commodity oriented Federal Supply Classes to the IMM (FSC manager) for management.
Naval Inventory Control Point, Mechanicsburg, PA 17055-0788
Naval ICP, Philadelphia, PA 19111
ISC | Originator | NIIN Status | Replaced / Replacement ISC | Replaced / Replacement Originator | Replacement NIIN Status | Replacement Date | Replaced / Replacement NSN | Decision Date |
---|---|---|---|---|---|---|---|---|
6 | TX | 0 | 7 Jul 1968 |
An item authorized for procurement that is in a specific Federal Supply Class (FSC) or item name grouping consisting primarily of items which are one-of-a-kind; therefore, little or no potential exists for elimination of items through formal item reduction studies.
Defense Supply Center Columbus, Columbus, OH 43218
Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.
Integrity | Originating | HMC | LCL | WCC | TCC | SHC | ADC | ACC | ASH | LTL | NMFC | NMFC Sub Item | UFC | Freight Description | Rail Variance |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
72D | Z | 9 | A | H | Z | M | 061360 | X | 34430 | COILS-YOKES-FOCUS-DEFLECTION-TV |
Communications/Electronics, other than SIGINT/EW or COMSEC. Repair Parts and Components
No special type of cargo code applicable
No special handling required
Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
No special handling required.
85
No Variation. NMFC and UFCC Match.
Defense Logistics Agency, Enterprise Business Systems
INSURANCE/NUMERIC STOCKAGE OBJECTIVE ITEM. Items which may be required occasionally or intermittently, and prudence requires that a nominal quantity of materiel be stocked due to the essentiality or the lead time of the item. 1. The item is centrally managed, stocked, and issued. 2. Requisitions will be submitted in accordance with IMM/Service requisitioning procedures.
Unclassified
1
Each - A numeric quantity of one item of supply. Do not use if a more specific term applies, such as kit, set, assortment, assembly, group, sheet, plate, strip or length.
TYPE I or TYPE II (Non-Deteriorative/No Shelf-Life) - An individual item of supply which is determined through an evaluation of technical test data and/or actual experience to be an item with a definite non-extendible period of shelf-life OR An individual item of supply having an assigned shelf-life time period that may be extended after completion of inspection/test/restorative action.
Department of the Navy
Defense Logistics Agency
Source | PICA / SICA | Packaging Category | Storage | Preservation | Clean/Dry | INT Qty | Unit Weight | Unit Size | Unit Pack Cube | Item Weight | Item Dims |
---|---|---|---|---|---|---|---|---|---|---|---|
P | P | 42 | 1 | AAA | 0.3 lbs | 0.032 cu ft |
Preservation Material | Wrapping Material | Cushioning / Dunnage | Cushioning Thickness | Unit Container | Intermediate Container | Unit Container Level | Special Marking | Level A Packing | Level B Packing | Minimal Packing | Optional Procedure |
---|---|---|---|---|---|---|---|---|---|---|---|
00 | EC | NA | B | D3 | D1 | 00 | Q | Q | O |
Primary Inventory Control Activity (PICA)
Primary Inventory Control Activity (PICA)
Container, watervaporproof bag, sealed, container
Any suitable process that is not injurious to the item.
No requirement
MIL-DTL-17667, Type II, neutral wrapping paper, creped
PPP-C-795, cellular plastic film cushioning; or A-A-3129, open cell plastic cushioning; or PPP-C-1797, polypropylene foam cushioning; or A-A-59136, polyethylene foam cushioning
1/2 inch thick
PPP-B-566, PPP-B-676, or ASTM-D5118, folding, setup or fiberboard box.
PPP-B-566 or PPP-B-676, folding or setup box.
No special marking
Packing shall be accomplished in accordance with table C.II for the packing level specified. Closure sealing and reinforcement shall be in accordance with applicable specification for shipping container.
Packing shall be accomplished in accordance with table C-II for the packing level specified. Closure sealing and reinforcement shall be in accordance with the appropriate shipping container specification.
Options can be exercised as to specific method of preservation or DoD approved packaging materials to be used. However, basic preservation method shall be retained, supplemental data shall be complied with, and unit package dimensions shall not be increased by more than one inch. Equal or better protection shall be given the item and there shall be no increase in the package cost.
MRC | Decoded Requirement | Clear Text Reply |
---|---|---|
CTHF | Contact Load Current Rating | 0.5 AMPERES RESISTIVE LOAD AC AT SEA LEVEL |
CTHF | Contact Load Current Rating | 1.0 AMPERES RESISTIVE LOAD DC AT SEA LEVEL |
CSHW | Contact Switching Action | BREAKS BEFORE MAKES EACH SECTION REAR |
CQMK | Contact Voltage Rating In Volts | 110.0 AC AT SEA LEVEL |
CQMK | Contact Voltage Rating In Volts | 28.0 DC AT SEA LEVEL |
ABNB | First Flat Length | 0.375 INCHES NOMINAL SINGLE ACTUATOR |
ABNC | Flat Height | 0.218 INCHES NOMINAL SINGLE ACTUATOR |
AXGY | Mounting Method | THREADED BUSHING SINGLE MOUNTING FACILITY |
CQJX | Nominal Thread Size | 0.375 INCHES SINGLE MOUNTING FACILITY |
AEFP | Nonturn Device Radius | 0.531 INCHES NOMINAL AT 3:00 O'CLOCK |
AFDC | Nonturn Device Type | TAB AT 3:00 O'CLOCK |
AFGA | Operating Temp Range | -25.0/+85.0 DEG CELSIUS |
AFBH | Individual Section Quantity | 4 |
AKPX | Pole Quantity | 1 EACH SECTION REAR |
ABWV | Shaft Diameter | 0.250 INCHES NOMINAL SINGLE ACTUATOR |
CRSJ | Shaft Type | ROUND, FLATTED SINGLE ACTUATOR |
ABXF | Shaft Length | 0.875 INCHES NOMINAL SINGLE ACTUATOR |
ABKW | Overall Height | 1.531 INCHES NOMINAL |
ABHP | Overall Length | 2.500 INCHES NOMINAL |
ABMK | Overall Width | 1.375 INCHES NOMINAL |
STYL | Style Designator | CIRCULAR WAFER, BUSHING MOUNT |
CRJH | Switch Actuator Indexing Position Quantity | 11 SINGLE ACTUATOR |
CSLC | Switch Actuator Positioning Increment | 30.0 DEGREES SINGLE ACTUATOR |
CTDN | Switch Actuator Stop Device Type | ADJUSTABLE STOP SINGLE ACTUATOR |
AJZE | Switch Contact Basic Design | NONPILE-UP SYMMETRICAL |
CSCF | Terminal Type | TAB, SOLDER LUG |
AAJD | Thread Class | 2A SINGLE MOUNTING FACILITY |
AASA | Thread Length | 0.375 INCHES NOMINAL SINGLE MOUNTING FACILITY |
THSD | Thread Series Designator | UNEF SINGLE MOUNTING FACILITY |
AKPY | Throw Quantity | 11 EACH SECTION REAR |