Manufacturer Part Number | RNCC | RNVC | Manufacturer Name | CAGE | |
---|---|---|---|---|---|
42092 | 3 - Design Control Reference | 2 - Production Item | HYDRA-ELECTRIC COMPANY | 98505 | ![]() |
M410G20A39 | 5 - Replaced / Discontinued | 9 - No Longer Used | BARKSDALE INC | 89326 | ![]() |
Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.
Secondary Reference. Any additional number, other than a primary number (codes 1,2,3,4) informative reference (code 6) or vendor item drawing reference (code 7) assigned to an item of production or supply by a commercial or Government organization, which represents the same item of production or supply to which the National Stock Number (NSN) was assigned. The reference number may have had an RNCC of 1, 2, 3, 4 or 7 but has since been replaced in the item-of-supply concept of the NSN by another primary number.
A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.
A specification, standard, or other reference number which is superseded, canceled, obsolete or discontinued and is coded Reference Number Category Code (RNCC) 5; a reference number for information only coded RNCC 6; or a reference number coded RNCC D.
FSG | FSC | NIIN | FIIG | INC | CRITICALITY | TYPE OF ITEM | MRC | DEMIL | HMIC | EDC | PMIC | ADPEC | DATE CREATED |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
59 | 5930 | 008819711 | A048B0 | 00206 | X | 4 | 9 | A | P | U | 1 Jan 1960 |
The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Partial Descriptive Item Identification (Type 1 Concept)
A Defense Logistics Information Service-generated code for items lacking but requiring an RPDMRC (i.e., through mass FIIG revision change an item may be downgraded from a type 1 to a reference or partial descriptive method item identification).
Non-MLI/ Non-SLI — Demilitarization not required.
Indicates there is no information in the HMIRS; however, the NSN is in a FSC in Table II of Federal Standard 313 and a MSDS may be required by the user. The requirement for a MSDS is dependent on a hazard determination of the supplier or the intended end use of the product.
Precious Metal Content is unknown.
MOE Rule | Former MOE | AMC | AMSC | NIMSC | IMC | IMC Activity | AAC | DSOR | Collaborators | Receivers | Effective Date | |||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
N9BN | N9ND | 3 | R | Z | GH | KE | 1 Nov 2005 |
Acquire directly from the actual manufacturer, whether or not the prime contractor is the actual manufacturer.
The data or the rights to use the data needed to purchase this part from additional sources are not owned by the Government and it has been determined that it is uneconomical to purchase them. Valid AMCs: 1, 2, 3, 4 and 5.
Integrated Management: Relinquishment of Service management of an item in designated commodity oriented Federal Supply Classes to the IMM (FSC manager) for management.
Naval Inventory Control Point, Mechanicsburg, PA 17055-0788
Naval ICP, Philadelphia, PA 19111
RNFC | RNCC | RNVC | DAC | RNAAC | RNSC | RNJC | SADC | MSDS | HCC | Reference Number | CAGE | |
---|---|---|---|---|---|---|---|---|---|---|---|---|
1 | 3 | 2 | 1 | TX | D | 42092 | 98505 | ![]() | ||||
1 | 5 | 9 | 1 | TX | B | M410G20A39 | 89326 | ![]() |
Number is formatted as configured on the originating document with the exception of the modification required in volume 2, chapter 2.9.Number is formatted as configured on the originating document with the exception of the modification required in volume 2, chapter 2.9 .
Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.
A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.
The reference number is represented by a drawing and the drawing was available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number. The RNAAC will furnish the drawing upon request.
Defense Supply Center Columbus, Columbus, OH 43218
Procurement authority of the manufacturer and reference number have not yet been checked. NOTE: This code is to be allocated to reference numbers still requiring checks on procurement authority.
Secondary Reference. Any additional number, other than a primary number (codes 1,2,3,4) informative reference (code 6) or vendor item drawing reference (code 7) assigned to an item of production or supply by a commercial or Government organization, which represents the same item of production or supply to which the National Stock Number (NSN) was assigned. The reference number may have had an RNCC of 1, 2, 3, 4 or 7 but has since been replaced in the item-of-supply concept of the NSN by another primary number.
A specification, standard, or other reference number which is superseded, canceled, obsolete or discontinued and is coded Reference Number Category Code (RNCC) 5; a reference number for information only coded RNCC 6; or a reference number coded RNCC D.
Manufacturer and/or reference number are not authorized for procurement. NOTE: This code may be used for obsolete or informative reference numbers only.
ISC | Originator | NIIN Status | Replaced / Replacement ISC | Replaced / Replacement Originator | Replacement NIIN Status | Replacement Date | Replaced / Replacement NSN | Decision Date |
---|---|---|---|---|---|---|---|---|
2 | TX | 0 | 4 Feb 1971 |
An item authorized for procurement which has been included in an item reduction study and which initially does not replace an item not authorized for procurement. In addition, in generic relationships, a code 2 item is related to a code 1 item.
Defense Supply Center Columbus, Columbus, OH 43218
Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.
Integrity | Originating | HMC | LCL | WCC | TCC | SHC | ADC | ACC | ASH | LTL | NMFC | NMFC Sub Item | UFC | Freight Description | Rail Variance |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
658 | Z | 9 | A | H | Z | M | 061360 | X | 34430 | COILS-YOKES-FOCUS-DEFLECTION-TV |
Electical Appliances, Small
No special type of cargo code applicable
No special handling required
Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
No special handling required.
85
No Variation. NMFC and UFCC Match.
Defense Logistics Agency, Enterprise Business Systems
NOT STOCKED, CENTRALLY PROCURED # (NON-STOCKED ITEMS) IMM/Service centrally managed but not stocked item. Procurement will be initiated only after receipt of a requisition.
Unclassified
1
Each - A numeric quantity of one item of supply. Do not use if a more specific term applies, such as kit, set, assortment, assembly, group, sheet, plate, strip or length.
TYPE I or TYPE II (Non-Deteriorative/No Shelf-Life) - An individual item of supply which is determined through an evaluation of technical test data and/or actual experience to be an item with a definite non-extendible period of shelf-life OR An individual item of supply having an assigned shelf-life time period that may be extended after completion of inspection/test/restorative action.
Department of the Navy
Defense Logistics Agency
Source | PICA / SICA | Packaging Category | Storage | Preservation | Clean/Dry | INT Qty | Unit Weight | Unit Size | Unit Pack Cube | Item Weight | Item Dims |
---|---|---|---|---|---|---|---|---|---|---|---|
P | P | 41 | 1 | AAA |
Preservation Material | Wrapping Material | Cushioning / Dunnage | Cushioning Thickness | Unit Container | Intermediate Container | Unit Container Level | Special Marking | Level A Packing | Level B Packing | Minimal Packing | Optional Procedure |
---|---|---|---|---|---|---|---|---|---|---|---|
00 | FA | 00 | 0 | D1 | DO | 00 | Q | Q | O |
Primary Inventory Control Activity (PICA)
Primary Inventory Control Activity (PICA)
Watervaporproof bag, sealed
Any suitable process that is not injurious to the item.
No requirement
MIL-P-130, laminated and creped wrapping paper
No requirement
Not Applicable
PPP-B-566 or PPP-B-676, folding or setup box.
Any suitable fiber box included in this table may be used (see J.4.9.1).
No special marking
Packing shall be accomplished in accordance with table C.II for the packing level specified. Closure sealing and reinforcement shall be in accordance with applicable specification for shipping container.
Packing shall be accomplished in accordance with table C-II for the packing level specified. Closure sealing and reinforcement shall be in accordance with the appropriate shipping container specification.
Options can be exercised as to specific method of preservation or DoD approved packaging materials to be used. However, basic preservation method shall be retained, supplemental data shall be complied with, and unit package dimensions shall not be increased by more than one inch. Equal or better protection shall be given the item and there shall be no increase in the package cost.
MRC | Decoded Requirement | Clear Text Reply |
---|---|---|
ABPM | Body Diameter | 3.000 INCHES NOMINAL |
ADAQ | Body Length | 1.438 INCHES NOMINAL |
CTYM | Contact Adjustment Range | +5.00/+70.00 ACTUATION POINT POUNDS PER SQUARE INCH AND +5.00/+70.00 DEACTUATION POINT POUNDS PER SQUARE INCH |
CQGB | Contact Action Stimulus | INCREASE |
CTYC | Contact Adjustability | DEACTUATION POINT ADJUSTABLE, PRESET AND ACTUATION POINT ADJUSTABLE, PRESET |
CTHF | Contact Load Current Rating | 2.0 AMPERES RESISTIVE LOAD FIRST VOLTAGE AND 2.0 AMPERES INDUCTIVE LOAD FIRST VOLTAGE AND 2.0 AMPERES LAMP LOAD FIRST VOLTAGE |
CTHF | Contact Load Current Rating | 2.0 AMPERES RESISTIVE LOAD SECOND VOLTAGE AND 2.0 AMPERES INDUCTIVE LOAD SECOND VOLTAGE AND 2.0 AMPERES LAMP LOAD SECOND VOLTAGE |
CTYX | Contact Stimulus Rating | 65.00 ACTUATION POINT MAXIMUM POUNDS PER SQUARE INCH AND 10.00 DIFFERENTIAL POINT NOMINAL POUNDS PER SQUARE INCH |
CTZB | Contact Voltage Rating In Volts | 115.0 AC AT SEA LEVEL FIRST VOLTAGE |
CTZB | Contact Voltage Rating In Volts | 28.0 DC AT SEA LEVEL SECOND VOLTAGE |
CBBL | Features Provided | ELECTRICAL BOX CONNECTOR |
MEDA | Media For Which Designed | GAS OR LIQUID |
CQYJ | Mounting Facility Pattern | FOUR POSITION RECTANGULAR |
ABTD | Mounting Slot Width | 0.219 INCHES NOMINAL |
AXGY | Mounting Method | SLOT AND UNTHREADED HOLE |
CQJX | Nominal Thread Size | 0.4375 INCHES SINGLE PRESSURE CONNECTION |
CRLD | Nonpile-Up Contact Arrangement | 1 POLE, DOUBLE THROW, ONE POSITION MOMENTARY |
AWTN | Operating Temp Rating | 125.0 DEG FAHRENHEIT MINIMUM AND 175.0 DEG FAHRENHEIT MAXIMUM |
STYL | Style Designator | CYLINDRICAL W/MOUNTING LUGS |
AFDS | Longest Horizontal Distance Between Mounting Centers | 1.500 INCHES NOMINAL |
AFDV | Longest Vertical Distance Between Mounting Centers | 3.000 INCHES NOMINAL |
CTZL | Pressure Connector Type | DOUBLE COMPRESSION, THREADED INTERNAL SINGLE CONNECTION |
AJZC | Pressure Switch Type | GAGE |
CQJB | Proof Pressure | 200.00 POUNDS PER SQUARE INCH GAGE |
CSCC | Sensing Element Burst Pressure | 300.00 POUNDS PER SQUARE INCH GAGE |
ABHP | Overall Length | 1.938 INCHES MAXIMUM |
ABMK | Overall Width | 3.625 INCHES NOMINAL |
AEBV | Unthreaded Mounting Hole Diameter | 0.219 INCHES NOMINAL |
CSCF | Terminal Type | CONNECTOR, RECEPTACLE |
AAJD | Thread Class | 3B SINGLE PRESSURE CONNECTION |
THSD | Thread Series Designator | UNF SINGLE PRESSURE CONNECTION |
CMLP | Thread Quantity Per Inch | 20 SINGLE PRESSURE CONNECTION |