Manufacturer Part Number | RNCC | RNVC | Manufacturer Name | CAGE | |
---|---|---|---|---|---|
MS16109-30-3CN | 2 - Definitive Specification or Standard Document | 2 - Production Item | MILITARY STANDARDS | 96906 | ![]() |
Definitive Government Specification or Standard Designator Reference. A part number, style number, or type designator included in or developed in accordance with a Government specification or standard which has the effect of fully identifying an item of supply. This code shall also be used for a Government specification or standard which, although not including part numbers, style numbers, or type designators, covers a single item of upply. These reference numbers may be coded with Reference Number Variation Code (RNVC) 1 in accordance with volume 2, paragraph 2.9.2.n.(4).
A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.
FSG | FSC | NIIN | FIIG | INC | CRITICALITY | TYPE OF ITEM | MRC | DEMIL | HMIC | EDC | PMIC | ADPEC | DATE CREATED |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
59 | 5930 | 009088128 | A052B0 | 02134 | X | 4 | 9 | A | P | U | 1 Jan 1960 |
The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Partial Descriptive Item Identification (Type 1 Concept)
A Defense Logistics Information Service-generated code for items lacking but requiring an RPDMRC (i.e., through mass FIIG revision change an item may be downgraded from a type 1 to a reference or partial descriptive method item identification).
Non-MLI/ Non-SLI — Demilitarization not required.
Indicates there is no information in the HMIRS; however, the NSN is in a FSC in Table II of Federal Standard 313 and a MSDS may be required by the user. The requirement for a MSDS is dependent on a hazard determination of the supplier or the intended end use of the product.
Precious Metal Content is unknown.
MOE Rule | Former MOE | AMC | AMSC | NIMSC | IMC | IMC Activity | AAC | DSOR | Collaborators | Receivers | Effective Date | |||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
ZR01 | 1 Jul 1997 |
ISC | Originator | NIIN Status | Replaced / Replacement ISC | Replaced / Replacement Originator | Replacement NIIN Status | Replacement Date | Replaced / Replacement NSN | Decision Date |
---|---|---|---|---|---|---|---|---|
3 | TX | 0 | 1 | TX | 0 | 7 Jun 1970 | 5930004887320 | 7 Apr 1970 |
An item which, as a result of a formal item reduction study, is accepted as not authorized for procurement.
Defense Supply Center Columbus, Columbus, OH 43218
Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.
An item authorized for procurement as a result of a formal item reduction study and accepted as a replacement for one or more items not authorized for procurement. In addition, in generic relationships, a code 1 item is related to a code 2 item.
Integrity | Originating | HMC | LCL | WCC | TCC | SHC | ADC | ACC | ASH | LTL | NMFC | NMFC Sub Item | UFC | Freight Description | Rail Variance |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
P | 658 | Z | 9 | A | H | Z | M | 061360 | X | 34430 | COILS-YOKES-FOCUS-DEFLECTION-TV |
77.5
Electical Appliances, Small
No special type of cargo code applicable
No special handling required
Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
No special handling required.
85
No Variation. NMFC and UFCC Match.
MRC | Decoded Requirement | Clear Text Reply |
---|---|---|
CTHF | Contact Load Current Rating | 1.0 AMPERES INDUCTIVE LOAD DC AT SEA LEVEL |
CTHF | Contact Load Current Rating | 2.0 AMPERES RESISTIVE LOAD AC AT SEA LEVEL AND 1.0 AMPERES INDUCTIVE LOAD AC AT SEA LEVEL |
CSHW | Contact Switching Action | BREAKS BEFORE MAKES EACH SECTION FRONT |
CSHW | Contact Switching Action | BREAKS BEFORE MAKES EACH SECTION REAR |
CQMK | Contact Voltage Rating In Volts | 115.0 AC AT SEA LEVEL |
CQMK | Contact Voltage Rating In Volts | 28.0 DC AT SEA LEVEL |
ABFE | Hazardous Locations/Environmental Protection | DUSTPROOF |
AXGY | Mounting Method | THREADED BUSHING SINGLE MOUNTING FACILITY |
CQJX | Nominal Thread Size | 0.375 INCHES SINGLE MOUNTING FACILITY |
AEFP | Nonturn Device Radius | 0.375 INCHES NOMINAL AT 3:00 O'CLOCK |
AFDC | Nonturn Device Type | TAB AT 3:00 O'CLOCK |
AFGA | Operating Temp Range | -65.0/+85.0 DEG CELSIUS |
AFBH | Individual Section Quantity | 3 |
CRSJ | Shaft Type | ROUND, FLATTED SINGLE ACTUATOR |
ADAV | Overall Diameter | 1.187 INCHES MAXIMUM |
ABHP | Overall Length | 1.782 INCHES MINIMUM AND 1.906 INCHES MAXIMUM |
FEAT | Special Features | ADDITIONAL NONTURN DEVICE TYPE SLOTTED BUSHING,NONTURN DEVICE RADIUS 0.170 IN. NOM AT 3:00 O,CLOCK |
STYL | Style Designator | CIRCULAR WAFER, BUSHING MOUNT |
CRJH | Switch Actuator Indexing Position Quantity | 12 SINGLE ACTUATOR |
CSLC | Switch Actuator Positioning Increment | 30.0 DEGREES SINGLE ACTUATOR |
AJZE | Switch Contact Basic Design | NONPILE-UP NONSYMMETRICAL |
CSCF | Terminal Type | TAB, SOLDER LUG |
TEST | Test Data Document | 81349-MIL-S-3786/4 SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL", "AVERAGE", "NOMINAL", ETC.). |
AASA | Thread Length | 0.422 INCHES MINIMUM SINGLE MOUNTING FACILITY AND 0.454 INCHES MAXIMUM SINGLE MOUNTING FACILITY |
THSD | Thread Series Designator | UNEF SINGLE MOUNTING FACILITY |