Manufacturer Part Number | RNCC | RNVC | Manufacturer Name | CAGE | |
---|---|---|---|---|---|
222-10NLM222198 | 3 - Design Control Reference | 2 - Production Item | DETROIT SWITCH, INC. | 19278 | ![]() |
222-10NLM-2221985 | C - Advisory Reference | 1 - Incomplete Part Number | DETROIT SWITCH, INC. | 19278 | ![]() |
Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.
Advisory Reference. A number assigned to an item of production or supply not included in the item-of-supply concept to which the NSN has been assigned (e.g., an item that may have been used in the preproduction equipment design which has since been redesigned or replaced). Use of this RNCC is restricted to conditions where cross-reference is required to establish identification to an item of supply. Additionally, there is not direct relationship of the reference number to the NSN other than a Service/Agency individual decision. (RNCC shall be used only in conjunction with RNVC 1.
A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.
A design control or other reference number that does NOT identify an item of production without the use of additional information, or a specific part, type, or similar reference number does NOT identify or item of supply without the use of additional information.
FSG | FSC | NIIN | FIIG | INC | CRITICALITY | TYPE OF ITEM | MRC | DEMIL | HMIC | EDC | PMIC | ADPEC | DATE CREATED |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
59 | 5930 | 009103393 | A048B0 | 00206 | X | 1 | A | P | U | 1 Jan 1960 |
The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Full Descriptive Item Identification
Non-MLI/ Non-SLI — Demilitarization not required.
Indicates there is no information in the HMIRS; however, the NSN is in a FSC in Table II of Federal Standard 313 and a MSDS may be required by the user. The requirement for a MSDS is dependent on a hazard determination of the supplier or the intended end use of the product.
Precious Metal Content is unknown.
MOE Rule | Former MOE | AMC | AMSC | NIMSC | IMC | IMC Activity | AAC | DSOR | Collaborators | Receivers | Effective Date | |||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
N9BN | N9ND | 0 | 0 | Z | GH | HD | 1 Nov 2005 | |||||||||||||||||||||||
ZW01 | 1 Dec 2005 |
Not Established
Integrated Management: Relinquishment of Service management of an item in designated commodity oriented Federal Supply Classes to the IMM (FSC manager) for management.
Naval Inventory Control Point, Mechanicsburg, PA 17055-0788
Naval Inventory Control Point, Mechanicsburg, PA 17055-0788
RNFC | RNCC | RNVC | DAC | RNAAC | RNSC | RNJC | SADC | MSDS | HCC | Reference Number | CAGE | |
---|---|---|---|---|---|---|---|---|---|---|---|---|
C | 1 | 6 | ZZ | AC | 222-10NLM-2221985 | 19278 | ![]() |
Advisory Reference. A number assigned to an item of production or supply not included in the item-of-supply concept to which the NSN has been assigned (e.g., an item that may have been used in the preproduction equipment design which has since been redesigned or replaced). Use of this RNCC is restricted to conditions where cross-reference is required to establish identification to an item of supply. Additionally, there is not direct relationship of the reference number to the NSN other than a Service/Agency individual decision. (RNCC shall be used only in conjunction with RNVC 1.
A design control or other reference number that does NOT identify an item of production without the use of additional information, or a specific part, type, or similar reference number does NOT identify or item of supply without the use of additional information.
The reference number is represented by technical documentation other than a drawing but the documentation was not available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number.
USA
Navy
ISC | Originator | NIIN Status | Replaced / Replacement ISC | Replaced / Replacement Originator | Replacement NIIN Status | Replacement Date | Replaced / Replacement NSN | Decision Date |
---|---|---|---|---|---|---|---|---|
2 | TX | 0 | 4 Feb 1971 |
An item authorized for procurement which has been included in an item reduction study and which initially does not replace an item not authorized for procurement. In addition, in generic relationships, a code 2 item is related to a code 1 item.
Defense Supply Center Columbus, Columbus, OH 43218
Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.
Integrity | Originating | HMC | LCL | WCC | TCC | SHC | ADC | ACC | ASH | LTL | NMFC | NMFC Sub Item | UFC | Freight Description | Rail Variance |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
658 | Z | 9 | A | H | Z | P | 061300 | X | 34410 | CIRCUIT-BREAKER-SWITCH-NOI |
Electical Appliances, Small
No special type of cargo code applicable
No special handling required
Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
No special handling required.
77.5
No Variation. NMFC and UFCC Match.
Defense Logistics Agency, Enterprise Business Systems
NOT STOCKED, CENTRALLY PROCURED # (NON-STOCKED ITEMS) IMM/Service centrally managed but not stocked item. Procurement will be initiated only after receipt of a requisition.
Unclassified
15
Each - A numeric quantity of one item of supply. Do not use if a more specific term applies, such as kit, set, assortment, assembly, group, sheet, plate, strip or length.
TYPE I or TYPE II (Non-Deteriorative/No Shelf-Life) - An individual item of supply which is determined through an evaluation of technical test data and/or actual experience to be an item with a definite non-extendible period of shelf-life OR An individual item of supply having an assigned shelf-life time period that may be extended after completion of inspection/test/restorative action.
Department of the Navy
Defense Logistics Agency
MRC | Decoded Requirement | Clear Text Reply |
---|---|---|
ADAU | Body Height | 2.750 INCHES NOMINAL |
CTYM | Contact Adjustment Range | +9.82/+94.70 ACTUATION POINT POUNDS PER SQUARE INCH ABSOLUTE |
CQGB | Contact Action Stimulus | INCREASE |
CTYC | Contact Adjustability | ACTUATION POINT ADJUSTABLE |
CTYS | Contact Adjustment Type | INTERNAL ACTUATION POINT SCREW |
CTHF | Contact Load Current Rating | 16.0 AMPERES INDUCTIVE LOAD FIRST VOLTAGE8.0 AMPERES INDUCTIVE LOAD SECOND VOLTAGE4.0 AMPERES INDUCTIVE LOAD THIRD VOLTAGE3.2 AMPERES INDUCTIVE LOAD FOURTH VOLTAGE9.6 AMPERES INDUCTIVE LOAD FIFTH VOLTAGE4.8 AMPERES INDUCTIVE LOAD SIXTH VOLTAGE2.5 AMPERES INDUCTIVE LOAD SEVENTH VOLTAGE2.0 AMPERES INDUCTIVE LOAD EIGHTH VOLTAGE |
CTZB | Contact Voltage Rating In Volts | 115.0 AC AT SEA LEVEL FIRST VOLTAGE230.0 AC AT SEA LEVEL SECOND VOLTAGE440.0 AC AT SEA LEVEL THIRD VOLTAGE550.0 AC AT SEA LEVEL FOURTH VOLTAGE115.0 DC AT SEA LEVEL FIFTH VOLTAGE230.0 DC AT SEA LEVEL SIXTH VOLTAGE440.0 DC AT SEA LEVEL SEVENTH VOLTAGE550.0 DC AT SEA LEVEL EIGHTH VOLTAGE |
CBBL | Features Provided | ELECTRICAL ACCESS PORT |
ABFE | Hazardous Locations/Environmental Protection | WATERTIGHT |
MEDA | Media For Which Designed | GAS |
CQYJ | Mounting Facility Pattern | ISOSCELES TRIANGLE |
AXGY | Mounting Method | BRACKET AND UNTHREADED HOLE |
CQJX | Nominal Thread Size | 0.250 INCHES SINGLE PRESSURE CONNECTION |
CRLD | Nonpile-Up Contact Arrangement | 2 POLE, DOUBLE THROW, ONE POSITION MOMENTARY |
STYL | Style Designator | RECTANGULAR |
AARX | Inside Diameter | 0.250 INCHES NOMINAL SINGLE CONNECTION |
AFDS | Longest Horizontal Distance Between Mounting Centers | 2.406 INCHES NOMINAL |
AFDV | Longest Vertical Distance Between Mounting Centers | 3.281 INCHES NOMINAL |
CTZL | Pressure Connector Type | INVERTED FLARE, THREADED INTERNAL SINGLE CONNECTION |
AJZC | Pressure Switch Type | GAGE |
CQJB | Proof Pressure | 216.00 POUNDS PER SQUARE INCH GAGE |
AFDT | Shortest Horizontal Distance Between Mounting Centers | 0.656 INCHES NOMINAL |
ABKW | Overall Height | 5.593 INCHES NOMINAL |
ABHP | Overall Length | 5.188 INCHES NOMINAL |
ABMK | Overall Width | 2.812 INCHES NOMINAL |
AEBV | Unthreaded Mounting Hole Diameter | 0.281 INCHES NOMINAL |
CSCF | Terminal Type | SCREW |
THSD | Thread Series Designator | PTF-SAE SHORT SINGLE PRESSURE CONNECTION |
CMLP | Thread Quantity Per Inch | 18 SINGLE PRESSURE CONNECTION |