5930-00-911-9003

SWITCH,ROTARY


5930-00-911-9003 (5930009119003, 009119003)
Part Numbers (2 listings): 737104-02 | 6-1925-2 |
Summary

FSG 59 / FSC 5930

DEMIL: A

DEMIL INT:

HMIC: P

Date Created: 1 Jan 1960

MSDS: None

Hazmat: None

Request a Quote


;



MASTER CROSS REFERENCE LIST (MCRL) | NSN 5930-00-911-9003 Submit RFQ
Manufacturer Part NumberRNCCRNVCManufacturer NameCAGE
737104-021 - Source of Control Reference2 - Production ItemGE AVIATION SYSTEMS LLC  35351    CAGE 35351  
6-1925-23 - Design Control Reference2 - Production ItemJANCO CORPORATION  91812    CAGE 91812  
Code Definitions

1 - Source of Control Reference

Reference Number Category Code (DRN_2910)


Source of Control Reference. The number assigned by a design control manufacturer of an end item of equipment, including a Government activity, to a drawing that restricts procurement (1) to the specified item(s) described on the drawing and (2) to the stated source(s) of supply designated thereon. These restrictions are imposed on the cognizant design activity to ensure procurement of the only item(s) known as a result of test or evaluation to be satisfactory for the stated critical application. Includes only those drawings which meet the definition for Source Control Drawing in MIL-STD-100. (Applicable only to type 1, 1B, 2, 4 and 4B item identifications.)

3 - Design Control Reference

Reference Number Category Code (DRN_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

2 - Production Item

Reference Number Variation Code (DRN_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.


FLIS - SEG A - IDENTIFICATION | NSN 5930-00-911-9003 Submit RFQ
FSGFSCNIINFIIGINCCRITICALITYTYPE OF ITEMMRCDEMILHMICEDCPMICADPECDATE CREATED
595930009119003A052B002134X1APU1 Jan 1960
Code Definitions

59

Federal Supply Group (FSG_3994/FSC_WI_FSG_3996)


Electrical and Electronic Equipment Components

5930

Federal Supply Class (FSC_3994/FSC_WI_FSC_3996)


Switches

009119003

National Item Identification Number (NCB_CD_4130/I_I_NBR_4131)


NSN 5930-00-911-9003

A052B0

Federal Item Identification Guide (FIIG_4065)

02134

Item Naming Code (INC_4080)

1 Jan 1960

NIIN Assignment Date (DT_NIIN_ASGMT_2180)

X

Item Criticality (CRITL_CD_FIIG_3843)


The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.

1

Type of Item Identification (TYP_II_4820)


Full Descriptive Item Identification

A

Demilitarization Code (DEMIL_CD_0167)


Non-MLI/ Non-SLI — Demilitarization not required.

P

Hazardous Material Indicator Code (HMIC_0865)


Indicates there is no information in the HMIRS; however, the NSN is in a FSC in Table II of Federal Standard 313 and a MSDS may be required by the user. The requirement for a MSDS is dependent on a hazard determination of the supplier or the intended end use of the product.

U

Precious Metals Indicator Code (PMIC_0802)


Precious Metal Content is unknown.


FLIS - SEG B - MOE RULE DATA | NSN 5930-00-911-9003 Submit RFQ
MOE RuleFormer MOEAMCAMSCNIMSCIMCIMC ActivityAACDSORCollaboratorsReceiversEffective Date
ZH
ZZ
ZH011 Apr 1991
DGX15HTX1 Nov 2005
YD011 Aug 2016
Code Definitions

5

Acquisition Method Code (AMC_2871)


Acquire only from the prime contractor although the engineering data identifies the Commercial and Government Entity Code (CAGE) and part number of a source other than the prime contractor. The DoD activity assigning this code shall furnish the name and CAGE Code of the prime contractor to the activity responsible for acquiring the part.

H

Acquisition Method Suffix Code (AMSC_2876)


The Government physically does not have in its possession sufficient, accurate, or legible data to purchase this part from other than current source(s). (NOTE: This code is applicable only to parts under immediate buy requirements and only as long as the deficiency is under review for resolution and appropriate recoding.) Valid AMCs: 1, 2, 3, 4 and 5.

TX

Supplementary Receivers (SUPPLM_RCVR_2534)


Defense Supply Center Columbus, Columbus, OH 43218


FLIS - SEG C - REFERENCE NUMBER | NSN 5930-00-911-9003 Submit RFQ
RNFCRNCCRNVCDACRNAACRNSCRNJCSADCMSDSHCCReference NumberCAGE
3121TXD737104-02  35351   CAGE/35351
3321TXD6-1925-2  91812   CAGE/91812
Code Definitions

3

Reference Number Format Code (RNFC_2920)


Number format is unknown. (Coded RNFC 3 by the Defense Logistics Information Service upon implementation of FLIS.)

1

Reference Number Category Code (RNCC_2910)


Source of Control Reference. The number assigned by a design control manufacturer of an end item of equipment, including a Government activity, to a drawing that restricts procurement (1) to the specified item(s) described on the drawing and (2) to the stated source(s) of supply designated thereon. These restrictions are imposed on the cognizant design activity to ensure procurement of the only item(s) known as a result of test or evaluation to be satisfactory for the stated critical application. Includes only those drawings which meet the definition for Source Control Drawing in MIL-STD-100. (Applicable only to type 1, 1B, 2, 4 and 4B item identifications.)

2

Reference Number Variation Code (RNVC_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.

1

Document Availability Code (DAC_2640)


The reference number is represented by a drawing and the drawing was available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number. The RNAAC will furnish the drawing upon request.

TX

Reference Number Action Activity Code (RNAAC_2900)


Defense Supply Center Columbus, Columbus, OH 43218

D

Reference Number Status Code (RNSC_2923)


Procurement authority of the manufacturer and reference number have not yet been checked. NOTE: This code is to be allocated to reference numbers still requiring checks on procurement authority.

3

Reference Number Category Code (RNCC_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.


FLIS - SEG G - FREIGHT DATA | NSN 5930-00-911-9003 Submit RFQ
IntegrityOriginatingHMCLCLWCCTCCSHCADCACCASHLTLNMFCNMFC Sub ItemUFCFreight DescriptionRail Variance
72DZ9AHZM061360X34430COILS-YOKES-FOCUS-DEFLECTION-TV
Code Definitions

XX

Originating Activity Code (ORIG_ACTY_CD_4210)


72D

Water Commodity Code (WRT_CMDTY_CD_9275)


Communications/Electronics, other than SIGINT/EW or COMSEC. Repair Parts and Components

Z

Type Cargo Code (TYPE_CGO_CD_9260)


No special type of cargo code applicable

9

Special Handling Code (SP_HDLG_CD_9240)


No special handling required

A

Air Dimension Code (AIR_DIM_CD_9220)


Shipment is not a consolidation and does not exceed 72 inches in any dimension.

H

Air Commodity Code (AIR_CMTY_HDLG_9215)


Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.

Z

Air Special Handling Code (AIR_CMTY_HDLG_9215)


No special handling required.

M

Less Than Truckload (CLAS_RTNG_CD_2770)


85

061360

National Motor Freight Classification Number (NMFC Item Number) (NMFC_2850)

X

NMFC Sub Item Number (SUB_ITM_NBR_0861)

34430

Uniform Freight Classification (UFC_CD_MODF_3040)

COILS-YOKES-FOCUS-DEFLECTION-TV

Freight Description (FRT_DESC_4020)

Rail Variance

Rail Variance (RAIL_VARI_CD_4760)


No Variation. NMFC and UFCC Match.


FLIS - SEG H - MANAGEMENT DATA | NSN 5930-00-911-9003 Submit RFQ
Unit PriceMOESOSAACCIICQUPReparabilityUISLC
DSSMSYU1EA0
Code Definitions

SMS

Source of Supply (SOS_CD_3690) or Source of Supply Modifier (SOSM_CD_2948)


Defense Logistics Agency, Enterprise Business Systems

Y

Acquisition Advice Code (AAC_2507)


TERMINAL ITEM (NON-STOCKED ITEMS) Future procurement is not authorized. No wholesale stock is available for issue. 1. Requisitions will not be processed to the wholesale manager. 2. Internal Service/agency requisitioning may be continued in accordance with the Service/agency requisitioning policies.

U

Controlled Item Inventory Code (CIIC_2863)


Unclassified

1

Quantity Unit Pack (QUP_6106)


1

EA

Unit of Issue (UI_3050)


Each - A numeric quantity of one item of supply. Do not use if a more specific term applies, such as kit, set, assortment, assembly, group, sheet, plate, strip or length.

0

Shelf Life Code (SLC_2943)


TYPE I or TYPE II (Non-Deteriorative/No Shelf-Life) - An individual item of supply which is determined through an evaluation of technical test data and/or actual experience to be an item with a definite non-extendible period of shelf-life OR An individual item of supply having an assigned shelf-life time period that may be extended after completion of inspection/test/restorative action.

DS

Service / Agency Code (MOE_CD_2833)


Defense Logistics Agency


FLIS - SEG M/V - CHARACTERISTICS DATA | NSN 5930-00-911-9003 Submit RFQ
MRCDecoded RequirementClear Text Reply
CTHFContact Load Current Rating3.0 AMPERES RESISTIVE LOAD DC AT SEA LEVEL
CTHFContact Load Current Rating5.0 AMPERES RESISTIVE LOAD AC AT SEA LEVEL
CSHWContact Switching ActionBREAKS BEFORE MAKES EACH SECTION REAR
CQMKContact Voltage Rating In Volts110.0 AC AT SEA LEVEL
CQMKContact Voltage Rating In Volts28.0 DC AT SEA LEVEL
ABFEHazardous Locations/Environmental ProtectionEXPLOSION PROOF
AXGYMounting MethodTHREADED BUSHING W/PANEL SEAL SINGLE MOUNTING FACILITY
CQJXNominal Thread Size0.469 INCHES SINGLE MOUNTING FACILITY
AFDCNonturn Device TypeSLOTTED BUSHING AT 1:45 O'CLOCK
AFGAOperating Temp Range-65.0/+85.0 DEG CELSIUS
AFBHIndividual Section Quantity3
AKPXPole Quantity1 EACH SECTION FRONT
CQTHRotor Through Connection Quantity1 EACH SECTION
ABWVShaft Diameter0.248 INCHES MINIMUM SINGLE ACTUATOR AND 0.252 INCHES MAXIMUM SINGLE ACTUATOR
CRSJShaft TypeROUND SINGLE ACTUATOR
ABXFShaft Length0.750 INCHES NOMINAL SINGLE ACTUATOR
ADAVOverall Diameter2.000 INCHES MAXIMUM
ABHPOverall Length2.500 INCHES NOMINAL
STYLStyle DesignatorTAP, CIRCULAR, BUSHING MOUNT
CRJHSwitch Actuator Indexing Position Quantity18 SINGLE ACTUATOR
CSLCSwitch Actuator Positioning Increment15.0 DEGREES SINGLE ACTUATOR
CTDNSwitch Actuator Stop Device TypeFIXED STOP SINGLE ACTUATOR
AJZESwitch Contact Basic DesignNONPILE-UP SYMMETRICAL
CSCFTerminal TypeTAB, SOLDER LUG
AAJDThread Class2A SINGLE MOUNTING FACILITY
AASAThread Length0.375 INCHES NOMINAL SINGLE MOUNTING FACILITY
CMLPThread Quantity Per Inch32 SINGLE MOUNTING FACILITY
THSDThread Series DesignatorUNS SINGLE MOUNTING FACILITY
AKPYThrow Quantity18 EACH SECTION REAR


Back to Top
Back to Top