Manufacturer Part Number | RNCC | RNVC | Manufacturer Name | CAGE | |
---|---|---|---|---|---|
80511 | 3 - Design Control Reference | 9 - No Longer Used | COOPER INDUSTRIES INC | 04009 | ![]() |
355-016 | E - Replace Reference Number | 8 - Replacement NSN | BACHARACH, INC. | 05083 | ![]() |
3391 | E - Replace Reference Number | 8 - Replacement NSN | FLEX-O-LATORS INC | 04930 | ![]() |
3391 | E - Replace Reference Number | 8 - Replacement NSN | COOPER INDUSTRIES INC | 04009 | ![]() |
Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.
Replaced Reference Number. A manufacturerÆs part number, government specification/standard or other design control reference number that is superseded, discontinued or replaced resulting from a cancel-use action on a NSN which was recorded with ISC 3 or E. This reference number is automatically moved and this code is automatically assigned, do not submit for cataloging purposes.
A specification, standard, or other reference number which is superseded, canceled, obsolete or discontinued and is coded Reference Number Category Code (RNCC) 5; a reference number for information only coded RNCC 6; or a reference number coded RNCC D.
A non-item-identifying reference number that is added to a replacement NSN as a result of a cancel-use action on a NSN recorded with ISC 3 or E. It is used to indentify the original item of supply/replaced item. This reference number is automatically moved and this code is automatically assigned, do not submit for cataloging purposes.
FSG | FSC | NIIN | FIIG | INC | CRITICALITY | TYPE OF ITEM | MRC | DEMIL | HMIC | EDC | PMIC | ADPEC | DATE CREATED |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
59 | 5930 | 009127519 | A053A0 | 00406 | X | 4 | 3 | A | P | U | 1 Jan 1960 |
The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Partial Descriptive Item Identification (Type 1 Concept)
An approved item name and FIIG exist but the item involved is so unique in design that it cannot be fully described in accordance with the FIIG.
Non-MLI/ Non-SLI — Demilitarization not required.
Indicates there is no information in the HMIRS; however, the NSN is in a FSC in Table II of Federal Standard 313 and a MSDS may be required by the user. The requirement for a MSDS is dependent on a hazard determination of the supplier or the intended end use of the product.
Precious Metal Content is unknown.
MOE Rule | Former MOE | AMC | AMSC | NIMSC | IMC | IMC Activity | AAC | DSOR | Collaborators | Receivers | Effective Date | |||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
YB01 | 1 Apr 1991 | |||||||||||||||||||||||||||||
ZG01 | 1 Apr 1991 | |||||||||||||||||||||||||||||
ZH01 | 1 Apr 1991 | |||||||||||||||||||||||||||||
A918 | A196 | 3 | D | Z | CD | AZ | CL | 1 Nov 2005 | ||||||||||||||||||||||
FXGX | FXTX | 3 | D | Z | SX | 1 Nov 2005 | ||||||||||||||||||||||||
MC49 | MC13 | 3 | D | Z | PA | 1 Nov 2005 | ||||||||||||||||||||||||
N9BN | N9ND | 3 | D | Z | GH | HD | KE | 1 Nov 2005 | ||||||||||||||||||||||
ZW01 | 1 Dec 2005 | |||||||||||||||||||||||||||||
ZB01 | 1 Mar 2008 | |||||||||||||||||||||||||||||
ZC01 | 1 Jan 2009 | |||||||||||||||||||||||||||||
ZP01 | 1 Jan 2009 | |||||||||||||||||||||||||||||
ZR01 | 1 Jan 2009 | |||||||||||||||||||||||||||||
YY01 | 1 Feb 2015 |
Acquire directly from the actual manufacturer, whether or not the prime contractor is the actual manufacturer.
The data needed to produce this item from additional sources is not physically available. Valid AMCs: 3, 4 and 5.
Integrated Management: Relinquishment of Service management of an item in designated commodity oriented Federal Supply Classes to the IMM (FSC manager) for management.
U.S. Army War Reserve Command, New Cumberland, PA 17070-5008
Oklahoma City Air Logistics Center, Tinker AFB, OK 73145-3043
Marine Corps Logistics Base, Albany, GA 31704-1128
Naval Inventory Control Point, Mechanicsburg, PA 17055-0788
Naval Inventory Control Point, Mechanicsburg, PA 17055-0788
Naval ICP, Philadelphia, PA 19111
U.S. Army Tank-Automotive and Armaments, Command, Warren, MI 48397-5000
U.S. Army Communications-Electronics, Fort Monmouth, NJ 07703-5006
RNFC | RNCC | RNVC | DAC | RNAAC | RNSC | RNJC | SADC | MSDS | HCC | Reference Number | CAGE | |
---|---|---|---|---|---|---|---|---|---|---|---|---|
3 | E | 8 | 5 | TX | D | 3391 | 04930 | ![]() | ||||
3 | E | 8 | 5 | TX | D | 355-016 | 05083 | ![]() | ||||
3 | E | 8 | 4 | TX | D | 3391 | 04009 | ![]() |
Number format is unknown. (Coded RNFC 3 by the Defense Logistics Information Service upon implementation of FLIS.)
Replaced Reference Number. A manufacturerÆs part number, government specification/standard or other design control reference number that is superseded, discontinued or replaced resulting from a cancel-use action on a NSN which was recorded with ISC 3 or E. This reference number is automatically moved and this code is automatically assigned, do not submit for cataloging purposes.
A non-item-identifying reference number that is added to a replacement NSN as a result of a cancel-use action on a NSN recorded with ISC 3 or E. It is used to indentify the original item of supply/replaced item. This reference number is automatically moved and this code is automatically assigned, do not submit for cataloging purposes.
The reference number is represented by a drawing, but the drawing was not available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number.
Defense Supply Center Columbus, Columbus, OH 43218
Procurement authority of the manufacturer and reference number have not yet been checked. NOTE: This code is to be allocated to reference numbers still requiring checks on procurement authority.
The reference number is represented by technical documentation other than a drawing and the documentation was available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number; however, the RNAAC cannot furnish the technical documentation.
ISC | Originator | NIIN Status | Replaced / Replacement ISC | Replaced / Replacement Originator | Replacement NIIN Status | Replacement Date | Replaced / Replacement NSN | Decision Date |
---|---|---|---|---|---|---|---|---|
5 | 9Z | 0 | 1 Jan 2009 |
An item authorized for procurement that has not yet been subject to item standardization.
DLIS-K, Battle Creek, MI 49037-3084
Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.
Integrity | Originating | HMC | LCL | WCC | TCC | SHC | ADC | ACC | ASH | LTL | NMFC | NMFC Sub Item | UFC | Freight Description | Rail Variance |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
72D | Z | 9 | A | H | Z | P | 061300 | X | 34410 | CIRCUIT-BREAKER-SWITCH-NOI |
Communications/Electronics, other than SIGINT/EW or COMSEC. Repair Parts and Components
No special type of cargo code applicable
No special handling required
Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
No special handling required.
77.5
No Variation. NMFC and UFCC Match.
Unit Price | MOE | SOS | AAC | CIIC | QUP | Reparability | UI | SLC |
---|---|---|---|---|---|---|---|---|
DA | SMS | J | U | 1 | Z | EA | 0 | |
DF | SMS | J | U | 1 | N | EA | 0 | |
DM | SMS | J | U | 1 | Z | EA | 0 | |
DN | SMS | J | U | 1 | EA | 0 | ||
DS | SMS | J | U | 1 | N | EA | 0 |
Defense Logistics Agency, Enterprise Business Systems
NOT STOCKED, CENTRALLY PROCURED # (NON-STOCKED ITEMS) IMM/Service centrally managed but not stocked item. Procurement will be initiated only after receipt of a requisition.
Unclassified
1
ARMY: This is a nonreparable item. If condemned or economically unserviceable, then dispose at the level authorized replace the item; MARINE CORPS: Nonreparable item. When unserviceable, condemn and dispose at the level indicated by the first digit of the maintenance code; NAVY: Special Program Consumables
Each - A numeric quantity of one item of supply. Do not use if a more specific term applies, such as kit, set, assortment, assembly, group, sheet, plate, strip or length.
TYPE I or TYPE II (Non-Deteriorative/No Shelf-Life) - An individual item of supply which is determined through an evaluation of technical test data and/or actual experience to be an item with a definite non-extendible period of shelf-life OR An individual item of supply having an assigned shelf-life time period that may be extended after completion of inspection/test/restorative action.
AIR FORCE ERRC XB3: Stock Fund (Except Munitions); DLA: This item has been reviewed and a determination made that the item cannot or should not be restored to a serviceable condition from an unserviceable condition; NAVY: 1I cog not stocked print on demand flat forms
Department of the Army
Department of the Air Force
U.S. Marine Corps
Department of the Navy
Defense Logistics Agency
Source | PICA / SICA | Packaging Category | Storage | Preservation | Clean/Dry | INT Qty | Unit Weight | Unit Size | Unit Pack Cube | Item Weight | Item Dims |
---|---|---|---|---|---|---|---|---|---|---|---|
P | P | 41 | 1 | AAA | 3in x 2in x 2in | 0.006 cu ft |
Preservation Material | Wrapping Material | Cushioning / Dunnage | Cushioning Thickness | Unit Container | Intermediate Container | Unit Container Level | Special Marking | Level A Packing | Level B Packing | Minimal Packing | Optional Procedure |
---|---|---|---|---|---|---|---|---|---|---|---|
00 | 00 | NA | X | D3 | 00 | Q | Q | O |
Primary Inventory Control Activity (PICA)
Primary Inventory Control Activity (PICA)
Watervaporproof bag, sealed
Any suitable process that is not injurious to the item.
No requirement
No requirement
PPP-C-795, cellular plastic film cushioning; or A-A-3129, open cell plastic cushioning; or PPP-C-1797, polypropylene foam cushioning; or A-A-59136, polyethylene foam cushioning
As required to protect the item or elements of the package
PPP-B-566, PPP-B-676, or ASTM-D5118, folding, setup or fiberboard box.
No special marking
Packing shall be accomplished in accordance with table C.II for the packing level specified. Closure sealing and reinforcement shall be in accordance with applicable specification for shipping container.
Packing shall be accomplished in accordance with table C-II for the packing level specified. Closure sealing and reinforcement shall be in accordance with the appropriate shipping container specification.
Options can be exercised as to specific method of preservation or DoD approved packaging materials to be used. However, basic preservation method shall be retained, supplemental data shall be complied with, and unit package dimensions shall not be increased by more than one inch. Equal or better protection shall be given the item and there shall be no increase in the package cost.
MRC | Decoded Requirement | Clear Text Reply |
---|---|---|
CRLD | Nonpile-Up Contact Arrangement | 1 POLE, SINGLE THROW, NORMALLY CLOSED, MOMENTARY ACTION SINGLE SWITCH UNIT |
AFXE | Maximum Voltage Rating In Volts | 120.0 AC |
CXQR | Contact Load Current Rating At Maximum Rated Voltage | 3.000 AMPERES RESISTIVE AC |
AAQL | Body Style | BUSHING MOUNTED |
ABXD | Bushing Length | 0.562 INCHES NOMINAL |
ADAT | Body Width | 0.562 INCHES NOMINAL |
ADAU | Body Height | 0.938 INCHES NOMINAL |
ABHP | Overall Length | 1.031 INCHES NOMINAL |
ABMK | Overall Width | 0.562 INCHES NOMINAL |
ABKW | Overall Height | 2.000 INCHES NOMINAL |
AFUS | Actuator Height | 0.500 INCHES NOMINAL |
AFVE | Actuator Inscription | KX SINGLE ACTUATOR |
TTQY | Terminal Type And Quantity | 2 TAB, SOLDER LUG |
AKNA | Inclosure Type | FULLY INCLOSED |
AXGY | Mounting Method | THREADED BUSHING |
THSD | Thread Series Designator | UNS |
CQJX | Nominal Thread Size | 0.469 INCHES |
CMLP | Thread Quantity Per Inch | 32 |
CBBL | Features Provided | ACTUATOR SEAL |