5930-00-914-5620

SWITCH,SENSITIVE


5930-00-914-5620 (5930009145620, 009145620)
Part Number (1 listing): BZF2-3AN4RH
Summary

FSG 59 / FSC 5930

DEMIL: A

DEMIL INT:

HMIC: P

Date Created: 14 Mar 1966

MSDS: None

Hazmat: None

Request a Quote


;



MASTER CROSS REFERENCE LIST (MCRL) | NSN 5930-00-914-5620 Submit RFQ
Manufacturer Part NumberRNCCRNVCManufacturer NameCAGE
BZF2-3AN4RH3 - Design Control Reference9 - No Longer UsedHONEYWELL INTERNATIONAL INC.  91929    CAGE 91929  
Code Definitions

3 - Design Control Reference

Reference Number Category Code (DRN_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

9 - No Longer Used

Reference Number Variation Code (DRN_4780)


A specification, standard, or other reference number which is superseded, canceled, obsolete or discontinued and is coded Reference Number Category Code (RNCC) 5; a reference number for information only coded RNCC 6; or a reference number coded RNCC D.


FLIS - SEG A - IDENTIFICATION | NSN 5930-00-914-5620 Submit RFQ
FSGFSCNIINFIIGINCCRITICALITYTYPE OF ITEMMRCDEMILHMICEDCPMICADPECDATE CREATED
595930009145620A053A000399XM9APU14 Mar 1966
Code Definitions

59

Federal Supply Group (FSG_3994/FSC_WI_FSG_3996)


Electrical and Electronic Equipment Components

5930

Federal Supply Class (FSC_3994/FSC_WI_FSC_3996)


Switches

009145620

National Item Identification Number (NCB_CD_4130/I_I_NBR_4131)


NSN 5930-00-914-5620

A053A0

Federal Item Identification Guide (FIIG_4065)

00399

Item Naming Code (INC_4080)

14 Mar 1966

NIIN Assignment Date (DT_NIIN_ASGMT_2180)

X

Item Criticality (CRITL_CD_FIIG_3843)


The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.

M

Type of Item Identification (TYP_II_4820)


Partial Descriptive - Reference Item Identification (Type 1A Concept)

9

Reference / Partial Descriptive Method Reason Code (RPDMRC_4765)


A Defense Logistics Information Service-generated code for items lacking but requiring an RPDMRC (i.e., through mass FIIG revision change an item may be downgraded from a type 1 to a reference or partial descriptive method item identification).

A

Demilitarization Code (DEMIL_CD_0167)


Non-MLI/ Non-SLI — Demilitarization not required.

P

Hazardous Material Indicator Code (HMIC_0865)


Indicates there is no information in the HMIRS; however, the NSN is in a FSC in Table II of Federal Standard 313 and a MSDS may be required by the user. The requirement for a MSDS is dependent on a hazard determination of the supplier or the intended end use of the product.

U

Precious Metals Indicator Code (PMIC_0802)


Precious Metal Content is unknown.


FLIS - SEG B - MOE RULE DATA | NSN 5930-00-914-5620 Submit RFQ
MOE RuleFormer MOEAMCAMSCNIMSCIMCIMC ActivityAACDSORCollaboratorsReceiversEffective Date
G12000L1 Apr 1991
Code Definitions

0

Acquisition Method Code (AMC_2871)


Not Established

L

Acquisition Advice Code (AAC_2507)


LOCAL PURCHASE (NON-STOCKED ITEMS) Defense Logistics Agency (DLA)/GSA/Service/Agency-managed items authorized for local purchase as normal means of support at base, post, camp or station level. Item not stocked in wholesale distribution system of IMM/Service/Agency ICP.


FLIS - SEG C - REFERENCE NUMBER | NSN 5930-00-914-5620 Submit RFQ
RNFCRNCCRNVCDACRNAACRNSCRNJCSADCMSDSHCCReference NumberCAGE
339275DBZF2-3AN4RH  91929   CAGE/91929
Code Definitions

3

Reference Number Format Code (RNFC_2920)


Number format is unknown. (Coded RNFC 3 by the Defense Logistics Information Service upon implementation of FLIS.)

3

Reference Number Category Code (RNCC_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

9

Reference Number Variation Code (RNVC_4780)


A specification, standard, or other reference number which is superseded, canceled, obsolete or discontinued and is coded Reference Number Category Code (RNCC) 5; a reference number for information only coded RNCC 6; or a reference number coded RNCC D.

2

Document Availability Code (DAC_2640)


The reference number is represented by a drawing and the drawing was available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number; however, the RNAAC cannot furnish the drawing.

75

Reference Number Action Activity Code (RNAAC_2900)


GSA, FSS/FCSC Washington, DC 20406

D

Reference Number Status Code (RNSC_2923)


Procurement authority of the manufacturer and reference number have not yet been checked. NOTE: This code is to be allocated to reference numbers still requiring checks on procurement authority.


FLIS - SEG E - ITEM STANDARDIZATION DATA | NSN 5930-00-914-5620 Submit RFQ
ISCOriginatorNIIN StatusReplaced / Replacement ISCReplaced / Replacement OriginatorReplacement NIIN StatusReplacement DateReplaced / Replacement NSNDecision Date
6TX028 Mar 1971
Code Definitions

6

Item Standardization Code (ISC_2650)


An item authorized for procurement that is in a specific Federal Supply Class (FSC) or item name grouping consisting primarily of items which are one-of-a-kind; therefore, little or no potential exists for elimination of items through formal item reduction studies.

TX

Originator of Standardization Decision (ORG_STDZN_DEC_9325)


Defense Supply Center Columbus, Columbus, OH 43218

0

NIIN Status Code (NIIN_STAT_CD_2670)


Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.

28 Mar 1971

Standardization Decision Date (DT_STDZN_DEC_2300)


FLIS - SEG G - FREIGHT DATA | NSN 5930-00-914-5620 Submit RFQ
IntegrityOriginatingHMCLCLWCCTCCSHCADCACCASHLTLNMFCNMFC Sub ItemUFCFreight DescriptionRail Variance
98
Code Definitions

98

Originating Activity Code (ORIG_ACTY_CD_4210)


DLIS-LFF, Battle Creek, MI 49037-3084

Rail Variance

Rail Variance (RAIL_VARI_CD_4760)


No Variation. NMFC and UFCC Match.


FLIS - SEG M/V - CHARACTERISTICS DATA | NSN 5930-00-914-5620 Submit RFQ
MRCDecoded RequirementClear Text Reply
AFURActuator Diameter0.094 INCHES NOMINAL
AFUUActuator Free Position Height0.670 INCHES NOMINAL
AFUQActuator StyleROUND
ADAUBody Height1.062 INCHES NOMINAL
ADAQBody Length1.938 INCHES NOMINAL
AAQLBody StyleHOLE MOUNTED
ADATBody Width0.688 INCHES NOMINAL
ABKQCenter To Center Distance Between Mounting Facilities Parallel To Length1.000 INCHES NOMINAL
CXQRContact Load Current Rating At Maximum Rated Voltage750.000 MILLIAMPERES RESISTIVE DC AND 500.000 MILLIAMPERES INDUCTIVE DC AND 15.000 AMPERES RESISTIVE AC
AFXEMaximum Voltage Rating In Volts460.0 AC AND 250.0 DC
CRLDNonpile-Up Contact Arrangement1 POLE, DOUBLE THROW, DOUBLE BREAK/DOUBLE MAKE, ONE POSITION MOMENTARY SINGLE SWITCH UNIT
AKNAInclosure TypeFULLY INCLOSED
AEBVUnthreaded Mounting Hole Diameter0.140 INCHES NOMINAL
CSJNSwitch Actuating Force26.0 OUNCES MAXIMUM
AFCGSwitch Actuator Quantity1
CRRMSwitch Release Force4.0 OUNCES MINIMUM
TTQYTerminal Type And Quantity4 SCREW