Manufacturer Part Number | RNCC | RNVC | Manufacturer Name | CAGE | |
---|---|---|---|---|---|
MS16109N1-5 | 2 - Definitive Specification or Standard Document | 2 - Production Item | MILITARY STANDARDS | 96906 | ![]() |
Definitive Government Specification or Standard Designator Reference. A part number, style number, or type designator included in or developed in accordance with a Government specification or standard which has the effect of fully identifying an item of supply. This code shall also be used for a Government specification or standard which, although not including part numbers, style numbers, or type designators, covers a single item of upply. These reference numbers may be coded with Reference Number Variation Code (RNVC) 1 in accordance with volume 2, paragraph 2.9.2.n.(4).
A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.
FSG | FSC | NIIN | FIIG | INC | CRITICALITY | TYPE OF ITEM | MRC | DEMIL | HMIC | EDC | PMIC | ADPEC | DATE CREATED |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
59 | 5930 | 009532509 | A052B0 | 02134 | X | 4 | 9 | A | P | A | 0 | 1 Jan 1962 |
The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Partial Descriptive Item Identification (Type 1 Concept)
A Defense Logistics Information Service-generated code for items lacking but requiring an RPDMRC (i.e., through mass FIIG revision change an item may be downgraded from a type 1 to a reference or partial descriptive method item identification).
Non-MLI/ Non-SLI — Demilitarization not required.
Indicates there is no information in the HMIRS; however, the NSN is in a FSC in Table II of Federal Standard 313 and a MSDS may be required by the user. The requirement for a MSDS is dependent on a hazard determination of the supplier or the intended end use of the product.
Item does not contain Precious Metal.
Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9)
MOE Rule | Former MOE | AMC | AMSC | NIMSC | IMC | IMC Activity | AAC | DSOR | Collaborators | Receivers | Effective Date | |||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
ZE01 | 1 Apr 1991 |
ISC | Originator | NIIN Status | Replaced / Replacement ISC | Replaced / Replacement Originator | Replacement NIIN Status | Replacement Date | Replaced / Replacement NSN | Decision Date |
---|---|---|---|---|---|---|---|---|
2 | TX | 0 | 27 Dec 1980 |
An item authorized for procurement which has been included in an item reduction study and which initially does not replace an item not authorized for procurement. In addition, in generic relationships, a code 2 item is related to a code 1 item.
Defense Supply Center Columbus, Columbus, OH 43218
Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.
Integrity | Originating | HMC | LCL | WCC | TCC | SHC | ADC | ACC | ASH | LTL | NMFC | NMFC Sub Item | UFC | Freight Description | Rail Variance |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
P | 658 | Z | 9 | A | H | Z | M | 061360 | X | 34430 | COILS-YOKES-FOCUS-DEFLECTION-TV |
77.5
Electical Appliances, Small
No special type of cargo code applicable
No special handling required
Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
No special handling required.
85
No Variation. NMFC and UFCC Match.
MRC | Decoded Requirement | Clear Text Reply |
---|---|---|
CTHF | Contact Load Current Rating | 1.0 AMPERES INDUCTIVE LOAD DC AT SEA LEVEL |
CTHF | Contact Load Current Rating | 2.0 AMPERES RESISTIVE LOAD AC AT SEA LEVEL AND 1.0 AMPERES INDUCTIVE LOAD AC AT SEA LEVEL |
CSHW | Contact Switching Action | BREAKS BEFORE MAKES SINGLE SECTION FRONT |
CSHW | Contact Switching Action | BREAKS BEFORE MAKES SINGLE SECTION REAR |
CQMK | Contact Voltage Rating In Volts | 115.0 AC AT SEA LEVEL |
CQMK | Contact Voltage Rating In Volts | 28.0 DC AT SEA LEVEL |
ABNB | First Flat Length | 0.250 INCHES NOMINAL SINGLE ACTUATOR |
ABNC | Flat Height | 0.214 INCHES NOMINAL SINGLE ACTUATOR |
AXGY | Mounting Method | THREADED BUSHING SINGLE MOUNTING FACILITY |
CQJX | Nominal Thread Size | 0.375 INCHES SINGLE MOUNTING FACILITY |
AFGA | Operating Temp Range | -65.0/+85.0 DEG CELSIUS |
AFBH | Individual Section Quantity | 1 |
ABXF | Shaft Length | 0.438 INCHES NOMINAL SINGLE ACTUATOR |
ABWV | Shaft Diameter | 0.250 INCHES NOMINAL SINGLE ACTUATOR |
CRSJ | Shaft Type | ROUND, FLATTED SINGLE ACTUATOR |
ADAV | Overall Diameter | 1.036 INCHES NOMINAL |
ABHP | Overall Length | 1.781 INCHES MINIMUM AND 1.906 INCHES MAXIMUM |
STYL | Style Designator | CIRCULAR WAFER, BUSHING MOUNT |
CRJH | Switch Actuator Indexing Position Quantity | 5 SINGLE ACTUATOR |
CSLC | Switch Actuator Positioning Increment | 36.0 DEGREES SINGLE ACTUATOR |
CSCF | Terminal Type | TAB, SOLDER LUG |
AASA | Thread Length | 0.437 INCHES NOMINAL SINGLE MOUNTING FACILITY |
THSD | Thread Series Designator | UNEF SINGLE MOUNTING FACILITY |