5930-00-993-1411

SWITCH,THERMOSTATIC


5930-00-993-1411 (5930009931411, 009931411)
Part Numbers (2 listings): 342C258H03 | 17800-60C |
Summary

FSG 59 / FSC 5930

DEMIL: A

DEMIL INT:

HMIC: P

Date Created: 1 Jan 1962

MSDS: None

Hazmat: None

Request a Quote


;



MASTER CROSS REFERENCE LIST (MCRL) | NSN 5930-00-993-1411 Submit RFQ
Manufacturer Part NumberRNCCRNVCManufacturer NameCAGE
342C258H033 - Design Control Reference2 - Production ItemNORTHROP GRUMMAN SYSTEMS CORPORATION  97942    CAGE 97942  
17800-60C5 - Replaced / Discontinued2 - Production ItemKIDDE TECHNOLOGIES INC  73168    CAGE 73168  
Code Definitions

3 - Design Control Reference

Reference Number Category Code (DRN_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

5 - Replaced / Discontinued

Reference Number Category Code (DRN_2910)


Secondary Reference. Any additional number, other than a primary number (codes 1,2,3,4) informative reference (code 6) or vendor item drawing reference (code 7) assigned to an item of production or supply by a commercial or Government organization, which represents the same item of production or supply to which the National Stock Number (NSN) was assigned. The reference number may have had an RNCC of 1, 2, 3, 4 or 7 but has since been replaced in the item-of-supply concept of the NSN by another primary number.

2 - Production Item

Reference Number Variation Code (DRN_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.


FLIS - SEG A - IDENTIFICATION | NSN 5930-00-993-1411 Submit RFQ
FSGFSCNIINFIIGINCCRITICALITYTYPE OF ITEMMRCDEMILHMICEDCPMICADPECDATE CREATED
595930009931411A048B000451X49APU1 Jan 1962
Code Definitions

59

Federal Supply Group (FSG_3994/FSC_WI_FSG_3996)


Electrical and Electronic Equipment Components

5930

Federal Supply Class (FSC_3994/FSC_WI_FSC_3996)


Switches

009931411

National Item Identification Number (NCB_CD_4130/I_I_NBR_4131)


NSN 5930-00-993-1411

A048B0

Federal Item Identification Guide (FIIG_4065)

00451

Item Naming Code (INC_4080)

1 Jan 1962

NIIN Assignment Date (DT_NIIN_ASGMT_2180)

X

Item Criticality (CRITL_CD_FIIG_3843)


The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.

4

Type of Item Identification (TYP_II_4820)


Partial Descriptive Item Identification (Type 1 Concept)

9

Reference / Partial Descriptive Method Reason Code (RPDMRC_4765)


A Defense Logistics Information Service-generated code for items lacking but requiring an RPDMRC (i.e., through mass FIIG revision change an item may be downgraded from a type 1 to a reference or partial descriptive method item identification).

A

Demilitarization Code (DEMIL_CD_0167)


Non-MLI/ Non-SLI — Demilitarization not required.

P

Hazardous Material Indicator Code (HMIC_0865)


Indicates there is no information in the HMIRS; however, the NSN is in a FSC in Table II of Federal Standard 313 and a MSDS may be required by the user. The requirement for a MSDS is dependent on a hazard determination of the supplier or the intended end use of the product.

U

Precious Metals Indicator Code (PMIC_0802)


Precious Metal Content is unknown.


FLIS - SEG B - MOE RULE DATA | NSN 5930-00-993-1411 Submit RFQ
MOE RuleFormer MOEAMCAMSCNIMSCIMCIMC ActivityAACDSORCollaboratorsReceiversEffective Date
ZC011 Apr 1991
Code Definitions

FLIS - SEG C - REFERENCE NUMBER | NSN 5930-00-993-1411 Submit RFQ
RNFCRNCCRNVCDACRNAACRNSCRNJCSADCMSDSHCCReference NumberCAGE
3321TXD342C258H03  97942   CAGE/97942
4525TXD17800-60C  73168   CAGE/73168
Code Definitions

3

Reference Number Format Code (RNFC_2920)


Number format is unknown. (Coded RNFC 3 by the Defense Logistics Information Service upon implementation of FLIS.)

3

Reference Number Category Code (RNCC_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

2

Reference Number Variation Code (RNVC_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.

1

Document Availability Code (DAC_2640)


The reference number is represented by a drawing and the drawing was available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number. The RNAAC will furnish the drawing upon request.

TX

Reference Number Action Activity Code (RNAAC_2900)


Defense Supply Center Columbus, Columbus, OH 43218

D

Reference Number Status Code (RNSC_2923)


Procurement authority of the manufacturer and reference number have not yet been checked. NOTE: This code is to be allocated to reference numbers still requiring checks on procurement authority.

4

Reference Number Format Code (RNFC_2920)


Number is totally in-the-clear (without modification) as originally configured by the manufacturer, design control activity, or supplier.

5

Reference Number Category Code (RNCC_2910)


Secondary Reference. Any additional number, other than a primary number (codes 1,2,3,4) informative reference (code 6) or vendor item drawing reference (code 7) assigned to an item of production or supply by a commercial or Government organization, which represents the same item of production or supply to which the National Stock Number (NSN) was assigned. The reference number may have had an RNCC of 1, 2, 3, 4 or 7 but has since been replaced in the item-of-supply concept of the NSN by another primary number.

5

Document Availability Code (DAC_2640)


The reference number is represented by a drawing, but the drawing was not available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number.


FLIS - SEG E - ITEM STANDARDIZATION DATA | NSN 5930-00-993-1411 Submit RFQ
ISCOriginatorNIIN StatusReplaced / Replacement ISCReplaced / Replacement OriginatorReplacement NIIN StatusReplacement DateReplaced / Replacement NSNDecision Date
2TX04 Feb 1971
Code Definitions

2

Item Standardization Code (ISC_2650)


An item authorized for procurement which has been included in an item reduction study and which initially does not replace an item not authorized for procurement. In addition, in generic relationships, a code 2 item is related to a code 1 item.

TX

Originator of Standardization Decision (ORG_STDZN_DEC_9325)


Defense Supply Center Columbus, Columbus, OH 43218

0

NIIN Status Code (NIIN_STAT_CD_2670)


Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.

4 Feb 1971

Standardization Decision Date (DT_STDZN_DEC_2300)


FLIS - SEG G - FREIGHT DATA | NSN 5930-00-993-1411 Submit RFQ
IntegrityOriginatingHMCLCLWCCTCCSHCADCACCASHLTLNMFCNMFC Sub ItemUFCFreight DescriptionRail Variance
P658Z9AHZP061300X34410CIRCUIT-BREAKER-SWITCH-NOI
Code Definitions

XX

Originating Activity Code (ORIG_ACTY_CD_4210)


P

Less Than Carload (LCL_CD_2760)


77.5

658

Water Commodity Code (WRT_CMDTY_CD_9275)


Electical Appliances, Small

Z

Type Cargo Code (TYPE_CGO_CD_9260)


No special type of cargo code applicable

9

Special Handling Code (SP_HDLG_CD_9240)


No special handling required

A

Air Dimension Code (AIR_DIM_CD_9220)


Shipment is not a consolidation and does not exceed 72 inches in any dimension.

H

Air Commodity Code (AIR_CMTY_HDLG_9215)


Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.

Z

Air Special Handling Code (AIR_CMTY_HDLG_9215)


No special handling required.

061300

National Motor Freight Classification Number (NMFC Item Number) (NMFC_2850)

X

NMFC Sub Item Number (SUB_ITM_NBR_0861)

34410

Uniform Freight Classification (UFC_CD_MODF_3040)

CIRCUIT-BREAKER-SWITCH-NOI

Freight Description (FRT_DESC_4020)

Rail Variance

Rail Variance (RAIL_VARI_CD_4760)


No Variation. NMFC and UFCC Match.


FLIS - SEG M/V - CHARACTERISTICS DATA | NSN 5930-00-993-1411 Submit RFQ
MRCDecoded RequirementClear Text Reply
ADAQBody Length4.833 INCHES NOMINAL
AEVVBulb Diameter0.618 INCHES MINIMUM AND 0.625 INCHES MAXIMUM
AEVUBulb Length2.968 INCHES NOMINAL
CTYMContact Adjustment Range-100.00/+400.00 ACTUATION POINT DEGREES FAHRENHEIT AND -100.00/+400.00 DEACTUATION POINT DEGREES FAHRENHEIT
CQGBContact Action StimulusINCREASE
CTYCContact AdjustabilityDEACTUATION POINT ADJUSTABLE, PRESET AND ACTUATION POINT ADJUSTABLE, PRESET
CTYSContact Adjustment TypeEXTERNAL DEACTUATION POINT DIAL AND EXTERNAL ACTUATION POINT DIAL
CTHFContact Load Current Rating10.0 AMPERES RESISTIVE LOAD SECOND VOLTAGE
CTHFContact Load Current Rating2.0 AMPERES RESISTIVE LOAD FOURTH VOLTAGE
CTHFContact Load Current Rating2.0 AMPERES RESISTIVE LOAD THIRD VOLTAGE
CTHFContact Load Current Rating5.0 AMPERES RESISTIVE LOAD FIRST VOLTAGE
CTYXContact Stimulus Rating60.00 ACTUATION POINT NOMINAL DEGREES CELSIUS AND 55.00 DEACTUATION POINT NOMINAL DEGREES CELSIUS AND 5.00 DIFFERENTIAL POINT NOMINAL DEGREES CELSIUS
CTZBContact Voltage Rating In Volts115.0 AC AT SEA LEVEL SECOND VOLTAGE
CTZBContact Voltage Rating In Volts115.0 DC AT SEA LEVEL THIRD VOLTAGE
CTZBContact Voltage Rating In Volts230.0 AC AT SEA LEVEL FIRST VOLTAGE
CTZBContact Voltage Rating In Volts28.0 DC AT SEA LEVEL FOURTH VOLTAGE
CBBLFeatures ProvidedTAMPER PROOF CAP
MEDAMedia For Which DesignedGAS OR LIQUID
AXGYMounting MethodTHREADED BUSHING
CQJXNominal Thread Size0.500 INCHES SINGLE THREADED BUSHING
CRLDNonpile-Up Contact Arrangement1 POLE, SINGLE THROW, BOTH POSITIONS MAINTAINED
ABHPOverall Length6.405 INCHES NOMINAL
STYLStyle DesignatorCYLINDRICAL
ADAVOverall Diameter3.750 INCHES NOMINAL
ASDBWidth Across Flats0.875 INCHES NOMINAL
AKBYTemp Sensing Element TypeBULB
CSCFTerminal TypeTAB W/SCREW
AASAThread Length0.625 INCHES NOMINAL SINGLE THREADED BUSHING
THSDThread Series DesignatorUNS SINGLE THREADED BUSHING
CMLPThread Quantity Per Inch14 SINGLE THREADED BUSHING


Back to Top
Back to Top