5930-01-034-0597

SWITCH,ROTARY


5930-01-034-0597 (5930010340597, 010340597)
Part Number (1 listing): S13-TB-4
Summary

FSG 59 / FSC 5930

DEMIL: A

DEMIL INT: 1

HMIC: P

Date Created: 18 Jan 1977

MSDS: None

Hazmat: None

Request a Quote


;



MASTER CROSS REFERENCE LIST (MCRL) | NSN 5930-01-034-0597 Submit RFQ
Manufacturer Part NumberRNCCRNVCManufacturer NameCAGE
S13-TB-43 - Design Control Reference2 - Production ItemILLINOIS TOOL WORKS INC.  04426      
Code Definitions

3 - Design Control Reference

Reference Number Category Code (DRN_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

2 - Production Item

Reference Number Variation Code (DRN_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.


FLIS - SEG A - IDENTIFICATION | NSN 5930-01-034-0597 Submit RFQ
FSGFSCNIINFIIGINCCRITICALITYTYPE OF ITEMMRCDEMILHMICEDCPMICADPECDATE CREATED
595930010340597A052B002134X1APG18 Jan 1977
Code Definitions

59

Federal Supply Group (FSG_3994/FSC_WI_FSG_3996)


Electrical and Electronic Equipment Components

5930

Federal Supply Class (FSC_3994/FSC_WI_FSC_3996)


Switches

010340597

National Item Identification Number (NCB_CD_4130/I_I_NBR_4131)


NSN 5930-01-034-0597

A052B0

Federal Item Identification Guide (FIIG_4065)

02134

Item Naming Code (INC_4080)

18 Jan 1977

NIIN Assignment Date (DT_NIIN_ASGMT_2180)

X

Item Criticality (CRITL_CD_FIIG_3843)


The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.

1

Type of Item Identification (TYP_II_4820)


Full Descriptive Item Identification

A

Demilitarization Code (DEMIL_CD_0167)


Non-MLI/ Non-SLI — Demilitarization not required.

P

Hazardous Material Indicator Code (HMIC_0865)


Indicates there is no information in the HMIRS; however, the NSN is in a FSC in Table II of Federal Standard 313 and a MSDS may be required by the user. The requirement for a MSDS is dependent on a hazard determination of the supplier or the intended end use of the product.

G

Precious Metals Indicator Code (PMIC_0802)


Item contains gold.


FLIS - SEG B - MOE RULE DATA | NSN 5930-01-034-0597 Submit RFQ
MOE RuleFormer MOEAMCAMSCNIMSCIMCIMC ActivityAACDSORCollaboratorsReceiversEffective Date
N9BNN9ND3LZHDHD1 Nov 2005
Code Definitions

3

Acquisition Method Code (AMC_2871)


Acquire directly from the actual manufacturer, whether or not the prime contractor is the actual manufacturer.

L

Acquisition Method Suffix Code (AMSC_2876)


The annual buy value of this part falls below the screening threshold of $10,000 but it has been screened for known source(s). (NOTE: This code shall not be used when screening parts entering the inventory. It shall not be assigned in preference to or supersede any other AMSC.) Valid AMCs: 1, 2, 3, 4 and 5.

Z

Item Management Code (IMC_2744)


Integrated Management: Relinquishment of Service management of an item in designated commodity oriented Federal Supply Classes to the IMM (FSC manager) for management.

HD

Item Management Coding Activity (IMC_ACTY_2748)


Naval Inventory Control Point, Mechanicsburg, PA 17055-0788

HDCollaborators

Supplementary Collaborators (SUPPLM_COLLBR_2533)


Naval Inventory Control Point, Mechanicsburg, PA 17055-0788


FLIS - SEG C - REFERENCE NUMBER | NSN 5930-01-034-0597 Submit RFQ
RNFCRNCCRNVCDACRNAACRNSCRNJCSADCMSDSHCCReference NumberCAGE
323TXS13-TB-4  04426  
Code Definitions

3

Reference Number Category Code (RNCC_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

2

Reference Number Variation Code (RNVC_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.

3

Document Availability Code (DAC_2640)


The reference number is represented by technical documentation other than a drawing and the documentation was available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number. The RNAAC will furnish the technical documentation upon request.

TX

Reference Number Action Activity Code (RNAAC_2900)


Defense Supply Center Columbus, Columbus, OH 43218


FLIS - SEG E - ITEM STANDARDIZATION DATA | NSN 5930-01-034-0597 Submit RFQ
ISCOriginatorNIIN StatusReplaced / Replacement ISCReplaced / Replacement OriginatorReplacement NIIN StatusReplacement DateReplaced / Replacement NSNDecision Date
2TX018 Aug 1984
Code Definitions

2

Item Standardization Code (ISC_2650)


An item authorized for procurement which has been included in an item reduction study and which initially does not replace an item not authorized for procurement. In addition, in generic relationships, a code 2 item is related to a code 1 item.

TX

Originator of Standardization Decision (ORG_STDZN_DEC_9325)


Defense Supply Center Columbus, Columbus, OH 43218

0

NIIN Status Code (NIIN_STAT_CD_2670)


Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.

18 Aug 1984

Standardization Decision Date (DT_STDZN_DEC_2300)


FLIS - SEG G - FREIGHT DATA | NSN 5930-01-034-0597 Submit RFQ
IntegrityOriginatingHMCLCLWCCTCCSHCADCACCASHLTLNMFCNMFC Sub ItemUFCFreight DescriptionRail Variance
TX72DZ9AHZP061300X34410CIRCUIT-BREAKER-SWITCH-NOI
Code Definitions

TX

Originating Activity Code (ORIG_ACTY_CD_4210)


Defense Supply Center Columbus, Columbus, OH 43218

72D

Water Commodity Code (WRT_CMDTY_CD_9275)


Communications/Electronics, other than SIGINT/EW or COMSEC. Repair Parts and Components

Z

Type Cargo Code (TYPE_CGO_CD_9260)


No special type of cargo code applicable

9

Special Handling Code (SP_HDLG_CD_9240)


No special handling required

A

Air Dimension Code (AIR_DIM_CD_9220)


Shipment is not a consolidation and does not exceed 72 inches in any dimension.

H

Air Commodity Code (AIR_CMTY_HDLG_9215)


Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.

Z

Air Special Handling Code (AIR_CMTY_HDLG_9215)


No special handling required.

P

Less Than Truckload (CLAS_RTNG_CD_2770)


77.5

061300

National Motor Freight Classification Number (NMFC Item Number) (NMFC_2850)

X

NMFC Sub Item Number (SUB_ITM_NBR_0861)

34410

Uniform Freight Classification (UFC_CD_MODF_3040)

CIRCUIT-BREAKER-SWITCH-NOI

Freight Description (FRT_DESC_4020)

Rail Variance

Rail Variance (RAIL_VARI_CD_4760)


No Variation. NMFC and UFCC Match.


FLIS - SEG H - MANAGEMENT DATA | NSN 5930-01-034-0597 Submit RFQ
Unit PriceMOESOSAACCIICQUPReparabilityUISLC
DNSMSJUCEA0
DSSMSJUCEA0
Code Definitions

SMS

Source of Supply (SOS_CD_3690) or Source of Supply Modifier (SOSM_CD_2948)


Defense Logistics Agency, Enterprise Business Systems

J

Acquisition Advice Code (AAC_2507)


NOT STOCKED, CENTRALLY PROCURED # (NON-STOCKED ITEMS) IMM/Service centrally managed but not stocked item. Procurement will be initiated only after receipt of a requisition.

U

Controlled Item Inventory Code (CIIC_2863)


Unclassified

C

Quantity Unit Pack (QUP_6106)


15

EA

Unit of Issue (UI_3050)


Each - A numeric quantity of one item of supply. Do not use if a more specific term applies, such as kit, set, assortment, assembly, group, sheet, plate, strip or length.

0

Shelf Life Code (SLC_2943)


TYPE I or TYPE II (Non-Deteriorative/No Shelf-Life) - An individual item of supply which is determined through an evaluation of technical test data and/or actual experience to be an item with a definite non-extendible period of shelf-life OR An individual item of supply having an assigned shelf-life time period that may be extended after completion of inspection/test/restorative action.

DN

Service / Agency Code (MOE_CD_2833)


Department of the Navy

DS

Service / Agency Code (MOE_CD_2833)


Defense Logistics Agency


FLIS - SEG M/V - CHARACTERISTICS DATA | NSN 5930-01-034-0597 Submit RFQ
MRCDecoded RequirementClear Text Reply
CTHFContact Load Current Rating250.0 MILLIAMPERES RESISTIVE LOAD AC AT SEA LEVEL
CTHFContact Load Current Rating250.0 MILLIAMPERES RESISTIVE LOAD DC AT SEA LEVEL AND 125.0 MILLIAMPERES INDUCTIVE LOAD DC AT SEA LEVEL
CSHWContact Switching ActionBREAKS BEFORE MAKES SINGLE SECTION REAR
CQMKContact Voltage Rating In Volts115.0 AC AT SEA LEVEL
CQMKContact Voltage Rating In Volts28.0 DC AT SEA LEVEL
ABFEHazardous Locations/Environmental ProtectionWATERTIGHT
AXGYMounting MethodTHREADED BUSHING W/PANEL SEAL SINGLE MOUNTING FACILITY
CQJXNominal Thread Size0.375 INCHES SINGLE MOUNTING FACILITY
AFDCNonturn Device TypeFLATTED BUSHING AT 3:00 O'CLOCK
AFBHIndividual Section Quantity1
AKPXPole Quantity3 SINGLE SECTION FRONT
PMLCPrecious Material And LocationCONTACT SURFACES GOLD AND CONTACTS AND ROTOR SURFACES SILVER
PRMTPrecious MaterialGOLD AND SILVER
CQTHRotor Through Connection Quantity3 SINGLE SECTION
ABWVShaft Diameter0.250 INCHES NOMINAL SINGLE ACTUATOR
ABXFShaft Length0.562 INCHES NOMINAL SINGLE ACTUATOR
CRSJShaft TypeROUND SINGLE ACTUATOR
ADAVOverall Diameter1.718 INCHES MAXIMUM
ABHPOverall Length1.656 INCHES NOMINAL
STYLStyle DesignatorTAP, CIRCULAR, BUSHING MOUNT
CRJHSwitch Actuator Indexing Position Quantity4 SINGLE ACTUATOR
CSLCSwitch Actuator Positioning Increment30.0 DEGREES SINGLE ACTUATOR
CTDNSwitch Actuator Stop Device TypeFIXED STOP SINGLE ACTUATOR
AJZESwitch Contact Basic DesignNONPILE-UP SYMMETRICAL
CSCFTerminal TypeTAB, SOLDER LUG
AAJDThread Class2A SINGLE MOUNTING FACILITY
AASAThread Length0.438 INCHES NOMINAL SINGLE MOUNTING FACILITY
THSDThread Series DesignatorUNEF SINGLE MOUNTING FACILITY
AKPYThrow Quantity4 SINGLE SECTION REAR


Back to Top
Back to Top