5930-01-048-0112

SWITCH,ROTARY


5930-01-048-0112 (5930010480112, 010480112)
Part Numbers (2 listings): L02327 | M3786/4-5019 |
Summary

FSG 59 / FSC 5930

DEMIL: A

DEMIL INT:

HMIC: P

Date Created: 17 Sep 1977

Unit Weight: 0.1 lbs

Unit Size: None

Unit Pack Cube: 0.020 cu ft

Replacement NSN:

5930-00-759-7697

Replacement Date: 16 Dec 1997

MSDS: None

Hazmat: None

Request a Quote


;



MASTER CROSS REFERENCE LIST (MCRL) | NSN 5930-01-048-0112 Submit RFQ
Manufacturer Part NumberRNCCRNVCManufacturer NameCAGE
L023273 - Design Control Reference2 - Production ItemDLA LAND AND MARITIME  16236    CAGE 16236  
M3786/4-50195 - Replaced / Discontinued9 - No Longer UsedGRAYHILL, INC  81073    CAGE 81073  
Code Definitions

3 - Design Control Reference

Reference Number Category Code (DRN_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

5 - Replaced / Discontinued

Reference Number Category Code (DRN_2910)


Secondary Reference. Any additional number, other than a primary number (codes 1,2,3,4) informative reference (code 6) or vendor item drawing reference (code 7) assigned to an item of production or supply by a commercial or Government organization, which represents the same item of production or supply to which the National Stock Number (NSN) was assigned. The reference number may have had an RNCC of 1, 2, 3, 4 or 7 but has since been replaced in the item-of-supply concept of the NSN by another primary number.

2 - Production Item

Reference Number Variation Code (DRN_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.

9 - No Longer Used

Reference Number Variation Code (DRN_4780)


A specification, standard, or other reference number which is superseded, canceled, obsolete or discontinued and is coded Reference Number Category Code (RNCC) 5; a reference number for information only coded RNCC 6; or a reference number coded RNCC D.


FLIS - SEG A - IDENTIFICATION | NSN 5930-01-048-0112 Submit RFQ
FSGFSCNIINFIIGINCCRITICALITYTYPE OF ITEMMRCDEMILHMICEDCPMICADPECDATE CREATED
595930010480112A052B002134Y1APU17 Sep 1977
Code Definitions

59

Federal Supply Group (FSG_3994/FSC_WI_FSG_3996)


Electrical and Electronic Equipment Components

5930

Federal Supply Class (FSC_3994/FSC_WI_FSC_3996)


Switches

010480112

National Item Identification Number (NCB_CD_4130/I_I_NBR_4131)


NSN 5930-01-048-0112

A052B0

Federal Item Identification Guide (FIIG_4065)

02134

Item Naming Code (INC_4080)

17 Sep 1977

NIIN Assignment Date (DT_NIIN_ASGMT_2180)

Y

Item Criticality (CRITL_CD_FIIG_3843)


The item does not have a nuclear hardened feature but does have other critical feature(s) such as tolerance, fit restriction or application.

1

Type of Item Identification (TYP_II_4820)


Full Descriptive Item Identification

A

Demilitarization Code (DEMIL_CD_0167)


Non-MLI/ Non-SLI — Demilitarization not required.

P

Hazardous Material Indicator Code (HMIC_0865)


Indicates there is no information in the HMIRS; however, the NSN is in a FSC in Table II of Federal Standard 313 and a MSDS may be required by the user. The requirement for a MSDS is dependent on a hazard determination of the supplier or the intended end use of the product.

U

Precious Metals Indicator Code (PMIC_0802)


Precious Metal Content is unknown.


FLIS - SEG B - MOE RULE DATA | NSN 5930-01-048-0112 Submit RFQ
MOE RuleFormer MOEAMCAMSCNIMSCIMCIMC ActivityAACDSORCollaboratorsReceiversEffective Date
ZF011 Apr 1991
ZH011 Aug 1995
ZW011 Dec 2005
YB011 Sep 2009
Code Definitions

FLIS - SEG C - REFERENCE NUMBER | NSN 5930-01-048-0112 Submit RFQ
RNFCRNCCRNVCDACRNAACRNSCRNJCSADCMSDSHCCReference NumberCAGE
321TXDL02327  16236   CAGE/16236
593TXBM3786/4-5019  81073   CAGE/81073
Code Definitions

3

Reference Number Category Code (RNCC_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

2

Reference Number Variation Code (RNVC_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.

1

Document Availability Code (DAC_2640)


The reference number is represented by a drawing and the drawing was available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number. The RNAAC will furnish the drawing upon request.

TX

Reference Number Action Activity Code (RNAAC_2900)


Defense Supply Center Columbus, Columbus, OH 43218

D

Reference Number Status Code (RNSC_2923)


Procurement authority of the manufacturer and reference number have not yet been checked. NOTE: This code is to be allocated to reference numbers still requiring checks on procurement authority.

5

Reference Number Category Code (RNCC_2910)


Secondary Reference. Any additional number, other than a primary number (codes 1,2,3,4) informative reference (code 6) or vendor item drawing reference (code 7) assigned to an item of production or supply by a commercial or Government organization, which represents the same item of production or supply to which the National Stock Number (NSN) was assigned. The reference number may have had an RNCC of 1, 2, 3, 4 or 7 but has since been replaced in the item-of-supply concept of the NSN by another primary number.

9

Reference Number Variation Code (RNVC_4780)


A specification, standard, or other reference number which is superseded, canceled, obsolete or discontinued and is coded Reference Number Category Code (RNCC) 5; a reference number for information only coded RNCC 6; or a reference number coded RNCC D.

3

Document Availability Code (DAC_2640)


The reference number is represented by technical documentation other than a drawing and the documentation was available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number. The RNAAC will furnish the technical documentation upon request.

B

Reference Number Status Code (RNSC_2923)


Manufacturer and/or reference number are not authorized for procurement. NOTE: This code may be used for obsolete or informative reference numbers only.


FLIS - SEG E - ITEM STANDARDIZATION DATA | NSN 5930-01-048-0112 Submit RFQ
ISCOriginatorNIIN StatusReplaced / Replacement ISCReplaced / Replacement OriginatorReplacement NIIN StatusReplacement DateReplaced / Replacement NSNDecision Date
3TX11TX016 Dec 1997 5930007597697 16 Dec 1997
Code Definitions

3

Item Standardization Code (ISC_2650)


An item which, as a result of a formal item reduction study, is accepted as not authorized for procurement.

TX

Originator of Standardization Decision (ORG_STDZN_DEC_9325)


Defense Supply Center Columbus, Columbus, OH 43218

1

NIIN Status Code (NIIN_STAT_CD_2670)


Represents an item for which a U.S. activity proposed cancelled-invalid or cancelled-use action or that the NIIN Status Code be changed to 9, and one or more NATO/FC did not concur in the proposal. See volume 4, chapter 4.9.Item is restricted to North Atlantic Treaty Organization/foreign country (NATO/FC) use only.Represents an item for which a U.S. activity proposed cancelled-invalid or cancelled-use action or that the NIIN Status Code be changed to 9, and one or more NATO/FC did not concur in the proposal. Item is restricted to North Atlantic Treaty Organization/foreign country (NATO/FC) use only.

1

Replaced / Replacement Item Standardization Code (ISC_2650)


An item authorized for procurement as a result of a formal item reduction study and accepted as a replacement for one or more items not authorized for procurement. In addition, in generic relationships, a code 1 item is related to a code 2 item.

0

Replaced / Replacement NIIN Status Code (NIIN_STAT_CD_2670)


Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.

16 Dec 1997

Date of Replacement Standardization Decision (DT_STDZN_DEC_2300)

5930-00-759-7697

Replaced / Replacement NSN (RP_NSN_STD_RL_8977 / RPLM_NSN_STDZ_9525)

16 Dec 1997

Standardization Decision Date (DT_STDZN_DEC_2300)


FLIS - SEG G - FREIGHT DATA | NSN 5930-01-048-0112 Submit RFQ
IntegrityOriginatingHMCLCLWCCTCCSHCADCACCASHLTLNMFCNMFC Sub ItemUFCFreight DescriptionRail Variance
TX658Z9AHZP061300X34410CIRCUIT-BREAKER-SWITCH-NOI
Code Definitions

TX

Originating Activity Code (ORIG_ACTY_CD_4210)


Defense Supply Center Columbus, Columbus, OH 43218

658

Water Commodity Code (WRT_CMDTY_CD_9275)


Electical Appliances, Small

Z

Type Cargo Code (TYPE_CGO_CD_9260)


No special type of cargo code applicable

9

Special Handling Code (SP_HDLG_CD_9240)


No special handling required

A

Air Dimension Code (AIR_DIM_CD_9220)


Shipment is not a consolidation and does not exceed 72 inches in any dimension.

H

Air Commodity Code (AIR_CMTY_HDLG_9215)


Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.

Z

Air Special Handling Code (AIR_CMTY_HDLG_9215)


No special handling required.

P

Less Than Truckload (CLAS_RTNG_CD_2770)


77.5

061300

National Motor Freight Classification Number (NMFC Item Number) (NMFC_2850)

X

NMFC Sub Item Number (SUB_ITM_NBR_0861)

34410

Uniform Freight Classification (UFC_CD_MODF_3040)

CIRCUIT-BREAKER-SWITCH-NOI

Freight Description (FRT_DESC_4020)

Rail Variance

Rail Variance (RAIL_VARI_CD_4760)


No Variation. NMFC and UFCC Match.


FLIS - SEG H - MANAGEMENT DATA | NSN 5930-01-048-0112 Submit RFQ
Unit PriceMOESOSAACCIICQUPReparabilityUISLC
DNSMSYU0EA0
DSSMSYU0EA0
Code Definitions

SMS

Source of Supply (SOS_CD_3690) or Source of Supply Modifier (SOSM_CD_2948)


Defense Logistics Agency, Enterprise Business Systems

Y

Acquisition Advice Code (AAC_2507)


TERMINAL ITEM (NON-STOCKED ITEMS) Future procurement is not authorized. No wholesale stock is available for issue. 1. Requisitions will not be processed to the wholesale manager. 2. Internal Service/agency requisitioning may be continued in accordance with the Service/agency requisitioning policies.

U

Controlled Item Inventory Code (CIIC_2863)


Unclassified

0

Quantity Unit Pack (QUP_6106)


No QUP

EA

Unit of Issue (UI_3050)


Each - A numeric quantity of one item of supply. Do not use if a more specific term applies, such as kit, set, assortment, assembly, group, sheet, plate, strip or length.

0

Shelf Life Code (SLC_2943)


TYPE I or TYPE II (Non-Deteriorative/No Shelf-Life) - An individual item of supply which is determined through an evaluation of technical test data and/or actual experience to be an item with a definite non-extendible period of shelf-life OR An individual item of supply having an assigned shelf-life time period that may be extended after completion of inspection/test/restorative action.

DN

Service / Agency Code (MOE_CD_2833)


Department of the Navy

DS

Service / Agency Code (MOE_CD_2833)


Defense Logistics Agency


FLIS - SEG W - PACKAGING DATA | NSN 5930-01-048-0112 Submit RFQ
SourcePICA / SICAPackaging CategoryStoragePreservationClean/DryINT QtyUnit WeightUnit SizeUnit Pack CubeItem WeightItem Dims
PPZZXXX0.1 lbs0.020 cu ft
Preservation MaterialWrapping MaterialCushioning / DunnageCushioning ThicknessUnit ContainerIntermediate ContainerUnit Container LevelSpecial MarkingLevel A PackingLevel B PackingMinimal PackingOptional Procedure
X00QQM
Code Definitions

P

Packaging Data Source Code (PK_DTA_SRC_CD_5148)


Primary Inventory Control Activity (PICA)

P

Primary / Secondary Inventory Control Code (PICA_SICA_IND_5099)


Primary Inventory Control Activity (PICA)

ZZ

Method of Preservation Code (MTHD_PRSRV_CD_5160)


See J.4.1.b

XXX

Intermediate Container Quantity (INTMD_CTN_QTY_5152)

0.1 lbs

Unit Pack Weight (UP_WT_5153)

0.020 cu ft

Unit Pack Cube (UP_CU_5155)

X

Thickness of Cushioning or Dunnage Code (THK_CUSH_DUN_5165)


As required to protect the item or elements of the package

00

Special Marking Code (SP_MKG_CD_5169)


No special marking

Q

Packing Requirement Code - For Level A (Maximum) Packing (LVL_A_PKG_CD_5170)


Packing shall be accomplished in accordance with table C.II for the packing level specified. Closure sealing and reinforcement shall be in accordance with applicable specification for shipping container.

Q

Packing Requirement Code - For Level B (Intermediate) Packing (LVL_B_PKG_CD_5171)


Packing shall be accomplished in accordance with table C-II for the packing level specified. Closure sealing and reinforcement shall be in accordance with the appropriate shipping container specification.

M

Optional Procedure Indicator Code (OPTNL_PRO_IND_5173)


All packaging data is mandatory for compliance and no substitutions are permitted. Fast packs should be included in this category.


FLIS - SEG M/V - CHARACTERISTICS DATA | NSN 5930-01-048-0112 Submit RFQ
MRCDecoded RequirementClear Text Reply
CTHFContact Load Current Rating75.0 MILLIAMPERES RESISTIVE LOAD AC AT SEA LEVEL
CTHFContact Load Current Rating250.0 MILLIAMPERES RESISTIVE LOAD DC AT SEA LEVEL AND 100.0 MILLIAMPERES INDUCTIVE LOAD DC AT SEA LEVEL
CSHWContact Switching ActionBREAKS BEFORE MAKES EACH SECTION REAR
CQMKContact Voltage Rating In Volts115.0 AC AT SEA LEVEL
CQMKContact Voltage Rating In Volts28.0 DC AT SEA LEVEL
CRTLCriticality Code JustificationFEAT
CSMWDetent Rotational Torque Range+1.000/+4.500 INCH-POUNDS SINGLE ACTUATOR
ABNBFirst Flat Length0.250 INCHES NOMINAL SINGLE ACTUATOR
ABNCFlat Height0.216 INCHES NOMINAL SINGLE ACTUATOR
ABFEHazardous Locations/Environmental ProtectionEXPLOSION PROOF
AXGYMounting MethodTHREADED BUSHING W/PANEL SEAL SINGLE MOUNTING FACILITY
CQJXNominal Thread Size0.375 INCHES SINGLE MOUNTING FACILITY
AFDCNonturn Device TypeSLOTTED BUSHING AT 3:00 O'CLOCK
AFGAOperating Temp Range-65.0/+125.0 DEG CELSIUS
AFBHIndividual Section Quantity1
AKPXPole Quantity3 EACH SECTION FRONT
CQTHRotor Through Connection Quantity3 SINGLE SECTION
ABWVShaft Diameter0.250 INCHES NOMINAL SINGLE ACTUATOR
CQRQShaft Flat/Slot Angular Location195.0 DEGREES FROM NONTURN DEVICE SINGLE ACTUATOR
ABXFShaft Length0.437 INCHES NOMINAL SINGLE ACTUATOR
CRSJShaft TypeROUND, FLATTED SINGLE ACTUATOR
ADAVOverall Diameter1.000 INCHES MINIMUM AND 1.306 INCHES MAXIMUM
ABHPOverall Length1.899 INCHES NOMINAL
FEATSpecial FeaturesITEM MUST COMPLY WITH REQUIREMENTS OF DEFENSE ELECTRONICS SUPPLY CENTER PRODUCTION STANDARD NO. L02327; FOR NAVY NUCLEAR PROPULSION PLANT PRODUCTS ONLY
STYLStyle DesignatorTAP, CIRCULAR, BUSHING MOUNT
CRJHSwitch Actuator Indexing Position Quantity4 SINGLE ACTUATOR
CSLCSwitch Actuator Positioning Increment30.0 DEGREES SINGLE ACTUATOR
CTDNSwitch Actuator Stop Device TypeFIXED STOP SINGLE ACTUATOR
AJZESwitch Contact Basic DesignNONPILE-UP SYMMETRICAL
CSCFTerminal TypeTAB, SOLDER LUG
AAJDThread Class2A SINGLE MOUNTING FACILITY
AASAThread Length0.437 INCHES NOMINAL SINGLE MOUNTING FACILITY
THSDThread Series DesignatorUNEF SINGLE MOUNTING FACILITY
AKPYThrow Quantity4 EACH SECTION REAR


Back to Top
Back to Top