5930-01-055-2051

SWITCH,THERMOSTATIC


5930-01-055-2051 (5930010552051, 010552051)
Part Number (1 listing): M1005-20181
Summary

FSG 59 / FSC 5930

DEMIL: A

DEMIL INT:

HMIC: P

Date Created: 3 Feb 1978

MSDS: None

Hazmat: None

Request a Quote


;



MASTER CROSS REFERENCE LIST (MCRL) | NSN 5930-01-055-2051 Submit RFQ
Manufacturer Part NumberRNCCRNVCManufacturer NameCAGE
M1005-201813 - Design Control Reference2 - Production ItemSENSATA TECHNOLOGIES, INC  82647    CAGE 82647  
Code Definitions

3 - Design Control Reference

Reference Number Category Code (DRN_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

2 - Production Item

Reference Number Variation Code (DRN_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.


FLIS - SEG A - IDENTIFICATION | NSN 5930-01-055-2051 Submit RFQ
FSGFSCNIINFIIGINCCRITICALITYTYPE OF ITEMMRCDEMILHMICEDCPMICADPECDATE CREATED
595930010552051A048B000451X1APU3 Feb 1978
Code Definitions

59

Federal Supply Group (FSG_3994/FSC_WI_FSG_3996)


Electrical and Electronic Equipment Components

5930

Federal Supply Class (FSC_3994/FSC_WI_FSC_3996)


Switches

010552051

National Item Identification Number (NCB_CD_4130/I_I_NBR_4131)


NSN 5930-01-055-2051

A048B0

Federal Item Identification Guide (FIIG_4065)

00451

Item Naming Code (INC_4080)

3 Feb 1978

NIIN Assignment Date (DT_NIIN_ASGMT_2180)

X

Item Criticality (CRITL_CD_FIIG_3843)


The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.

1

Type of Item Identification (TYP_II_4820)


Full Descriptive Item Identification

A

Demilitarization Code (DEMIL_CD_0167)


Non-MLI/ Non-SLI — Demilitarization not required.

P

Hazardous Material Indicator Code (HMIC_0865)


Indicates there is no information in the HMIRS; however, the NSN is in a FSC in Table II of Federal Standard 313 and a MSDS may be required by the user. The requirement for a MSDS is dependent on a hazard determination of the supplier or the intended end use of the product.

U

Precious Metals Indicator Code (PMIC_0802)


Precious Metal Content is unknown.


FLIS - SEG B - MOE RULE DATA | NSN 5930-01-055-2051 Submit RFQ
MOE RuleFormer MOEAMCAMSCNIMSCIMCIMC ActivityAACDSORCollaboratorsReceiversEffective Date
YA011 Oct 2000
YS011 Feb 2015
Code Definitions

FLIS - SEG C - REFERENCE NUMBER | NSN 5930-01-055-2051 Submit RFQ
RNFCRNCCRNVCDACRNAACRNSCRNJCSADCMSDSHCCReference NumberCAGE
43249ZDM1005-20181  82647   CAGE/82647
Code Definitions

4

Reference Number Format Code (RNFC_2920)


Number is totally in-the-clear (without modification) as originally configured by the manufacturer, design control activity, or supplier.

3

Reference Number Category Code (RNCC_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

2

Reference Number Variation Code (RNVC_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.

4

Document Availability Code (DAC_2640)


The reference number is represented by technical documentation other than a drawing and the documentation was available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number; however, the RNAAC cannot furnish the technical documentation.

9Z

Reference Number Action Activity Code (RNAAC_2900)


DLIS-K, Battle Creek, MI 49037-3084

D

Reference Number Status Code (RNSC_2923)


Procurement authority of the manufacturer and reference number have not yet been checked. NOTE: This code is to be allocated to reference numbers still requiring checks on procurement authority.


FLIS - SEG E - ITEM STANDARDIZATION DATA | NSN 5930-01-055-2051 Submit RFQ
ISCOriginatorNIIN StatusReplaced / Replacement ISCReplaced / Replacement OriginatorReplacement NIIN StatusReplacement DateReplaced / Replacement NSNDecision Date
59703 Feb 1978
Code Definitions

5

Item Standardization Code (ISC_2650)


An item authorized for procurement that has not yet been subject to item standardization.

97

Originator of Standardization Decision (ORG_STDZN_DEC_9325)


DLIS-LFF, Battle Creek, MI 49037-3084

0

NIIN Status Code (NIIN_STAT_CD_2670)


Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.

3 Feb 1978

Standardization Decision Date (DT_STDZN_DEC_2300)


FLIS - SEG G - FREIGHT DATA | NSN 5930-01-055-2051 Submit RFQ
IntegrityOriginatingHMCLCLWCCTCCSHCADCACCASHLTLNMFCNMFC Sub ItemUFCFreight DescriptionRail Variance
9ZP658ZZAHZP061300X34410CIRCUIT-BREAKER-SWITCH-NOI
Code Definitions

9Z

Originating Activity Code (ORIG_ACTY_CD_4210)


DLIS-K, Battle Creek, MI 49037-3084

P

Less Than Carload (LCL_CD_2760)


77.5

658

Water Commodity Code (WRT_CMDTY_CD_9275)


Electical Appliances, Small

Z

Type Cargo Code (TYPE_CGO_CD_9260)


No special type of cargo code applicable

Z

Special Handling Code (SP_HDLG_CD_9240)


No special handling required. Heavy Lift (HL). Five short tons (10,000 lbs) or more. Applies to any piece, package, or palletized, unitized or containerized unit (excluding SEAVAN/MILVAN). Outsized Dimensions. Dimensions of any piece, package, or palletized, unitized or containerized unit (excluding SEAVAN/MILVAN, CONEXs, and POVs) which exceed six (6) feet in any dimension.

A

Air Dimension Code (AIR_DIM_CD_9220)


Shipment is not a consolidation and does not exceed 72 inches in any dimension.

H

Air Commodity Code (AIR_CMTY_HDLG_9215)


Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.

Z

Air Special Handling Code (AIR_CMTY_HDLG_9215)


No special handling required.

061300

National Motor Freight Classification Number (NMFC Item Number) (NMFC_2850)

X

NMFC Sub Item Number (SUB_ITM_NBR_0861)

34410

Uniform Freight Classification (UFC_CD_MODF_3040)

CIRCUIT-BREAKER-SWITCH-NOI

Freight Description (FRT_DESC_4020)

Rail Variance

Rail Variance (RAIL_VARI_CD_4760)


No Variation. NMFC and UFCC Match.


FLIS - SEG M/V - CHARACTERISTICS DATA | NSN 5930-01-055-2051 Submit RFQ
MRCDecoded RequirementClear Text Reply
ABPMBody Diameter0.640 INCHES MAXIMUM
ADAUBody Height0.385 INCHES NOMINAL
CQGBContact Action StimulusINCREASE
CTYCContact AdjustabilityDEACTUATION POINT NOT ADJUSTABLE AND ACTUATION POINT NOT ADJUSTABLE
CTHFContact Load Current Rating1.0 AMPERES RESISTIVE LOAD FIRST VOLTAGE
CTHFContact Load Current Rating5.0 AMPERES RESISTIVE LOAD SECOND VOLTAGE
CTHFContact Load Current Rating5.0 AMPERES RESISTIVE LOAD THIRD VOLTAGE
CTYXContact Stimulus Rating-5.00 ACTUATION POINT MINIMUM DEGREES FAHRENHEIT AND 15.00 ACTUATION POINT MAXIMUM DEGREES FAHRENHEIT AND -30.00 DEACTUATION POINT MINIMUM DEGREES FAHRENHEIT AND 10.00 DEACTUATION POINT MAXIMUM GALLONS PER MINUTE
CTZBContact Voltage Rating In Volts30.0 DC AT SEA LEVEL THIRD VOLTAGE
AEJNDistance Between Mounting Facility Centers0.937 INCHES NOMINAL
CBBLFeatures ProvidedHERMETICALLY SEALED CASE
FREQFrequency In Hertz60.0 FIRST VOLTAGE
FREQFrequency In Hertz60.0 SECOND VOLTAGE
MEDAMedia For Which DesignedGAS OR LIQUID
CQYJMounting Facility PatternTWO POSITION IN-LINE
AXGYMounting MethodBRACKET
CRLDNonpile-Up Contact Arrangement1 POLE, SINGLE THROW, NORMALLY OPEN, MOMENTARY ACTION
AWTNOperating Temp Rating-85.0 DEG FAHRENHEIT MINIMUM AND 550.0 DEG FAHRENHEIT MAXIMUM
ABHPOverall Length1.200 INCHES MINIMUM AND 1.260 INCHES MAXIMUM
STYLStyle DesignatorDISC W/FLANGE
ABKWOverall Height0.607 INCHES NOMINAL
AKBYTemp Sensing Element TypeINTERNAL SENSOR
CSCFTerminal TypeTAB, SOLDER LUG


Back to Top