5930-01-069-6764

SWITCH,THERMOSTATIC


5930-01-069-6764 (5930010696764, 010696764)
Part Numbers (8 listings): 2645376PC5A | AASK37635REVDPC16 | 575-3802-1444381REVBPCLSWITCH | 222-10NL-22-1115 | 222-10NL2221115 | CSK37668REV4PCLSWITCH | AASK37635REVBPC16 | DFW-47-TS-06 |
Summary

FSG 59 / FSC 5930

DEMIL: A

DEMIL INT:

HMIC: P

Date Created: 22 Dec 1978

MSDS: None

Hazmat: None

Request a Quote


;



MASTER CROSS REFERENCE LIST (MCRL) | NSN 5930-01-069-6764 Submit RFQ
Manufacturer Part NumberRNCCRNVCManufacturer NameCAGE
2645376PC5A3 - Design Control Reference2 - Production ItemNAVAL SEA SYSTEMS COMMAND  53711    CAGE 53711  
AASK37635REVDPC163 - Design Control Reference2 - Production ItemCHROMALOX, INC.  65586    CAGE 65586  
575-3802-1444381REVBPCLSWITCH3 - Design Control Reference2 - Production ItemNAVAL SHIP SYSTEMS COMMAND  80064    CAGE 80064  
222-10NL-22-11155 - Replaced / Discontinued2 - Production ItemDETROIT SWITCH, INC.  19278      
222-10NL22211155 - Replaced / Discontinued2 - Production ItemDETROIT SWITCH, INC.  19278      
CSK37668REV4PCLSWITCH5 - Replaced / Discontinued2 - Production ItemWOODWARD, INC.  31361      
AASK37635REVBPC165 - Replaced / Discontinued2 - Production ItemWOODWARD, INC.  31361      
DFW-47-TS-065 - Replaced / Discontinued9 - No Longer UsedELECTRIC BOAT CORPORATION  96169    CAGE 96169  
CSK37668REV4PCLSWITCH5 - Replaced / Discontinued9 - No Longer UsedWOODWARD, INC.  66503      
AASK37635REVBPC165 - Replaced / Discontinued9 - No Longer UsedWOODWARD, INC.  66503      
Code Definitions

3 - Design Control Reference

Reference Number Category Code (DRN_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

5 - Replaced / Discontinued

Reference Number Category Code (DRN_2910)


Secondary Reference. Any additional number, other than a primary number (codes 1,2,3,4) informative reference (code 6) or vendor item drawing reference (code 7) assigned to an item of production or supply by a commercial or Government organization, which represents the same item of production or supply to which the National Stock Number (NSN) was assigned. The reference number may have had an RNCC of 1, 2, 3, 4 or 7 but has since been replaced in the item-of-supply concept of the NSN by another primary number.

2 - Production Item

Reference Number Variation Code (DRN_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.

9 - No Longer Used

Reference Number Variation Code (DRN_4780)


A specification, standard, or other reference number which is superseded, canceled, obsolete or discontinued and is coded Reference Number Category Code (RNCC) 5; a reference number for information only coded RNCC 6; or a reference number coded RNCC D.


FLIS - SEG A - IDENTIFICATION | NSN 5930-01-069-6764 Submit RFQ
FSGFSCNIINFIIGINCCRITICALITYTYPE OF ITEMMRCDEMILHMICEDCPMICADPECDATE CREATED
595930010696764A048B000451X1APS22 Dec 1978
Code Definitions

59

Federal Supply Group (FSG_3994/FSC_WI_FSG_3996)


Electrical and Electronic Equipment Components

5930

Federal Supply Class (FSC_3994/FSC_WI_FSC_3996)


Switches

010696764

National Item Identification Number (NCB_CD_4130/I_I_NBR_4131)


NSN 5930-01-069-6764

A048B0

Federal Item Identification Guide (FIIG_4065)

00451

Item Naming Code (INC_4080)

22 Dec 1978

NIIN Assignment Date (DT_NIIN_ASGMT_2180)

X

Item Criticality (CRITL_CD_FIIG_3843)


The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.

1

Type of Item Identification (TYP_II_4820)


Full Descriptive Item Identification

A

Demilitarization Code (DEMIL_CD_0167)


Non-MLI/ Non-SLI — Demilitarization not required.

P

Hazardous Material Indicator Code (HMIC_0865)


Indicates there is no information in the HMIRS; however, the NSN is in a FSC in Table II of Federal Standard 313 and a MSDS may be required by the user. The requirement for a MSDS is dependent on a hazard determination of the supplier or the intended end use of the product.

S

Precious Metals Indicator Code (PMIC_0802)


Item contains silver.


FLIS - SEG B - MOE RULE DATA | NSN 5930-01-069-6764 Submit RFQ
MOE RuleFormer MOEAMCAMSCNIMSCIMCIMC ActivityAACDSORCollaboratorsReceiversEffective Date
YB
ZC
ZZ
ZC011 Apr 1991
YB011 May 1997
C9113R1 Nov 2005
N9BN3RZHDGTHXHD1 Nov 2005
Code Definitions

3

Acquisition Method Code (AMC_2871)


Acquire directly from the actual manufacturer, whether or not the prime contractor is the actual manufacturer.

R

Acquisition Method Suffix Code (AMSC_2876)


The data or the rights to use the data needed to purchase this part from additional sources are not owned by the Government and it has been determined that it is uneconomical to purchase them. Valid AMCs: 1, 2, 3, 4 and 5.

Z

Item Management Code (IMC_2744)


Integrated Management: Relinquishment of Service management of an item in designated commodity oriented Federal Supply Classes to the IMM (FSC manager) for management.

HD

Item Management Coding Activity (IMC_ACTY_2748)


Naval Inventory Control Point, Mechanicsburg, PA 17055-0788

HXCollaborators

Supplementary Collaborators (SUPPLM_COLLBR_2533)


Navy ICP, Mechanicsburg, PA 17055-0788

HDCollaborators

Supplementary Collaborators (SUPPLM_COLLBR_2533)


Naval Inventory Control Point, Mechanicsburg, PA 17055-0788


FLIS - SEG C - REFERENCE NUMBER | NSN 5930-01-069-6764 Submit RFQ
RNFCRNCCRNVCDACRNAACRNSCRNJCSADCMSDSHCCReference NumberCAGE
4321TXD2645376PC5A  53711   CAGE/53711
3325TXDAASK37635REVDPC16  65586   CAGE/65586
4523TXD222-10NL-22-1115  19278  
4523TXD222-10NL2221115  19278  
525ZZAASK37635REVBPC16  31361  
525ZZCSK37668REV4PCLSWITCH  31361  
3595ZZBAASK37635REVBPC16  66503  
3595ZZBCSK37668REV4PCLSWITCH  66503  
4595TXBDFW-47-TS-06  96169   CAGE/96169
Code Definitions

4

Reference Number Format Code (RNFC_2920)


Number is totally in-the-clear (without modification) as originally configured by the manufacturer, design control activity, or supplier.

3

Reference Number Category Code (RNCC_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

2

Reference Number Variation Code (RNVC_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.

1

Document Availability Code (DAC_2640)


The reference number is represented by a drawing and the drawing was available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number. The RNAAC will furnish the drawing upon request.

TX

Reference Number Action Activity Code (RNAAC_2900)


Defense Supply Center Columbus, Columbus, OH 43218

D

Reference Number Status Code (RNSC_2923)


Procurement authority of the manufacturer and reference number have not yet been checked. NOTE: This code is to be allocated to reference numbers still requiring checks on procurement authority.

3

Reference Number Format Code (RNFC_2920)


Number format is unknown. (Coded RNFC 3 by the Defense Logistics Information Service upon implementation of FLIS.)

5

Document Availability Code (DAC_2640)


The reference number is represented by a drawing, but the drawing was not available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number.

5

Reference Number Category Code (RNCC_2910)


Secondary Reference. Any additional number, other than a primary number (codes 1,2,3,4) informative reference (code 6) or vendor item drawing reference (code 7) assigned to an item of production or supply by a commercial or Government organization, which represents the same item of production or supply to which the National Stock Number (NSN) was assigned. The reference number may have had an RNCC of 1, 2, 3, 4 or 7 but has since been replaced in the item-of-supply concept of the NSN by another primary number.

3

Document Availability Code (DAC_2640)


The reference number is represented by technical documentation other than a drawing and the documentation was available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number. The RNAAC will furnish the technical documentation upon request.

ZZ

Reference Number Action Activity Code (RNAAC_2900)


USA

9

Reference Number Variation Code (RNVC_4780)


A specification, standard, or other reference number which is superseded, canceled, obsolete or discontinued and is coded Reference Number Category Code (RNCC) 5; a reference number for information only coded RNCC 6; or a reference number coded RNCC D.

B

Reference Number Status Code (RNSC_2923)


Manufacturer and/or reference number are not authorized for procurement. NOTE: This code may be used for obsolete or informative reference numbers only.


FLIS - SEG G - FREIGHT DATA | NSN 5930-01-069-6764 Submit RFQ
IntegrityOriginatingHMCLCLWCCTCCSHCADCACCASHLTLNMFCNMFC Sub ItemUFCFreight DescriptionRail Variance
TX658Z9AHZP061300X34410CIRCUIT-BREAKER-SWITCH-NOI
Code Definitions

TX

Originating Activity Code (ORIG_ACTY_CD_4210)


Defense Supply Center Columbus, Columbus, OH 43218

658

Water Commodity Code (WRT_CMDTY_CD_9275)


Electical Appliances, Small

Z

Type Cargo Code (TYPE_CGO_CD_9260)


No special type of cargo code applicable

9

Special Handling Code (SP_HDLG_CD_9240)


No special handling required

A

Air Dimension Code (AIR_DIM_CD_9220)


Shipment is not a consolidation and does not exceed 72 inches in any dimension.

H

Air Commodity Code (AIR_CMTY_HDLG_9215)


Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.

Z

Air Special Handling Code (AIR_CMTY_HDLG_9215)


No special handling required.

P

Less Than Truckload (CLAS_RTNG_CD_2770)


77.5

061300

National Motor Freight Classification Number (NMFC Item Number) (NMFC_2850)

X

NMFC Sub Item Number (SUB_ITM_NBR_0861)

34410

Uniform Freight Classification (UFC_CD_MODF_3040)

CIRCUIT-BREAKER-SWITCH-NOI

Freight Description (FRT_DESC_4020)

Rail Variance

Rail Variance (RAIL_VARI_CD_4760)


No Variation. NMFC and UFCC Match.


FLIS - SEG H - MANAGEMENT DATA | NSN 5930-01-069-6764 Submit RFQ
Unit PriceMOESOSAACCIICQUPReparabilityUISLC
DNSMSZU1EA0
DSSMSZU1EA0
GPSMSZU1EA0
Code Definitions

SMS

Source of Supply (SOS_CD_3690) or Source of Supply Modifier (SOSM_CD_2948)


Defense Logistics Agency, Enterprise Business Systems

Z

Acquisition Advice Code (AAC_2507)


INSURANCE/NUMERIC STOCKAGE OBJECTIVE ITEM. Items which may be required occasionally or intermittently, and prudence requires that a nominal quantity of materiel be stocked due to the essentiality or the lead time of the item. 1. The item is centrally managed, stocked, and issued. 2. Requisitions will be submitted in accordance with IMM/Service requisitioning procedures.

U

Controlled Item Inventory Code (CIIC_2863)


Unclassified

1

Quantity Unit Pack (QUP_6106)


1

EA

Unit of Issue (UI_3050)


Each - A numeric quantity of one item of supply. Do not use if a more specific term applies, such as kit, set, assortment, assembly, group, sheet, plate, strip or length.

0

Shelf Life Code (SLC_2943)


TYPE I or TYPE II (Non-Deteriorative/No Shelf-Life) - An individual item of supply which is determined through an evaluation of technical test data and/or actual experience to be an item with a definite non-extendible period of shelf-life OR An individual item of supply having an assigned shelf-life time period that may be extended after completion of inspection/test/restorative action.

DN

Service / Agency Code (MOE_CD_2833)


Department of the Navy

DS

Service / Agency Code (MOE_CD_2833)


Defense Logistics Agency

GP

Service / Agency Code (MOE_CD_2833)


U.S. Coast Guard


FLIS - SEG M/V - CHARACTERISTICS DATA | NSN 5930-01-069-6764 Submit RFQ
MRCDecoded RequirementClear Text Reply
ADAUBody Height2.750 INCHES NOMINAL
AEVVBulb Diameter0.688 INCHES NOMINAL
AEVUBulb Length3.625 INCHES NOMINAL
AEVTCapillary Tube Length120.0 INCHES NOMINAL
CQGBContact Action StimulusINCREASE
CTYCContact AdjustabilityACTUATION POINT ADJUSTABLE
CTYMContact Adjustment Range+140.00/+215.00 ACTUATION POINT DEGREES FAHRENHEIT
CTYSContact Adjustment TypeEXTERNAL ACTUATION POINT SCREW
CTHFContact Load Current Rating16.0 AMPERES INDUCTIVE LOAD FIRST VOLTAGE
CTHFContact Load Current Rating2.0 AMPERES INDUCTIVE LOAD EIGHTH VOLTAGE
CTHFContact Load Current Rating8.0 AMPERES INDUCTIVE LOAD SECOND VOLTAGE
CTHFContact Load Current Rating9.6 AMPERES INDUCTIVE LOAD FIFTH VOLTAGE
CTHFContact Load Current Rating2.5 AMPERES INDUCTIVE LOAD SEVENTH VOLTAGE
CTHFContact Load Current Rating3.2 AMPERES INDUCTIVE LOAD FOURTH VOLTAGE
CTHFContact Load Current Rating4.0 AMPERES INDUCTIVE LOAD THIRD VOLTAGE
CTHFContact Load Current Rating4.8 AMPERES INDUCTIVE LOAD SIXTH VOLTAGE
CTZBContact Voltage Rating In Volts115.0 AC AT SEA LEVEL FIRST VOLTAGE
CTZBContact Voltage Rating In Volts115.0 DC AT SEA LEVEL FIFTH VOLTAGE
CTZBContact Voltage Rating In Volts230.0 DC AT SEA LEVEL SIXTH VOLTAGE
CTZBContact Voltage Rating In Volts230.0 AC AT SEA LEVEL SECOND VOLTAGE
CTZBContact Voltage Rating In Volts440.0 AC AT SEA LEVEL THIRD VOLTAGE
CTZBContact Voltage Rating In Volts440.0 DC AT SEA LEVEL SEVENTH VOLTAGE
CTZBContact Voltage Rating In Volts550.0 AC AT SEA LEVEL FOURTH VOLTAGE
CTZBContact Voltage Rating In Volts550.0 DC AT SEA LEVEL EIGHTH VOLTAGE
CBBLFeatures ProvidedELECTRICAL ACCESS PORT
ABFEHazardous Locations/Environmental ProtectionDUSTPROOF AND VIBRATION RESISTANT AND WATERTIGHT
MEDAMedia For Which DesignedGAS OR LIQUID
CQYJMounting Facility PatternISOSCELES TRIANGLE
AXGYMounting MethodBRACKET AND UNTHREADED HOLE
CRLDNonpile-Up Contact Arrangement1 POLE, DOUBLE THROW, ONE POSITION MOMENTARY
AWTNOperating Temp Rating245.0 DEG FAHRENHEIT MAXIMUM
ABHPOverall Length5.188 INCHES NOMINAL
STYLStyle DesignatorRECTANGULAR
AFDSLongest Horizontal Distance Between Mounting Centers2.406 INCHES NOMINAL
AFDVLongest Vertical Distance Between Mounting Centers3.281 INCHES NOMINAL
PMLCPrecious Material And LocationCONTACTS SILVER
PRMTPrecious MaterialSILVER
AFDTShortest Horizontal Distance Between Mounting Centers0.656 INCHES NOMINAL
ABKWOverall Height5.687 INCHES NOMINAL
ABMKOverall Width2.812 INCHES NOMINAL
AEBVUnthreaded Mounting Hole Diameter0.281 INCHES NOMINAL
AKBYTemp Sensing Element TypeCAPILLARY TUBE-BULB
CSCFTerminal TypeSCREW


Back to Top
Back to Top