5930-01-069-7648

SWITCH,TOGGLE


5930-01-069-7648 (5930010697648, 010697648)
Part Numbers (2 listings): 7105SD9V30BE | 91373279 |
Summary

FSG 59 / FSC 5930

DEMIL: A

DEMIL INT:

HMIC: P

Date Created: 23 Dec 1978

MSDS: None

Hazmat: None

Request a Quote


;



MASTER CROSS REFERENCE LIST (MCRL) | NSN 5930-01-069-7648 Submit RFQ
Manufacturer Part NumberRNCCRNVCManufacturer NameCAGE
7105SD9V30BE3 - Design Control Reference2 - Production ItemC AND K COMPONENTS INC  09353      
913732795 - Replaced / Discontinued2 - Production ItemTHALES DEFENCE & SECURITY  D2416    CAGE D2416  
913732795 - Replaced / Discontinued2 - Production ItemTHALES AIR SYSTEMS SA  F8224    CAGE F8224  
Code Definitions

3 - Design Control Reference

Reference Number Category Code (DRN_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

5 - Replaced / Discontinued

Reference Number Category Code (DRN_2910)


Secondary Reference. Any additional number, other than a primary number (codes 1,2,3,4) informative reference (code 6) or vendor item drawing reference (code 7) assigned to an item of production or supply by a commercial or Government organization, which represents the same item of production or supply to which the National Stock Number (NSN) was assigned. The reference number may have had an RNCC of 1, 2, 3, 4 or 7 but has since been replaced in the item-of-supply concept of the NSN by another primary number.

2 - Production Item

Reference Number Variation Code (DRN_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.


FLIS - SEG A - IDENTIFICATION | NSN 5930-01-069-7648 Submit RFQ
FSGFSCNIINFIIGINCCRITICALITYTYPE OF ITEMMRCDEMILHMICEDCPMICADPECDATE CREATED
595930010697648A053A000184X46APU23 Dec 1978
Code Definitions

59

Federal Supply Group (FSG_3994/FSC_WI_FSG_3996)


Electrical and Electronic Equipment Components

5930

Federal Supply Class (FSC_3994/FSC_WI_FSC_3996)


Switches

010697648

National Item Identification Number (NCB_CD_4130/I_I_NBR_4131)


NSN 5930-01-069-7648

A053A0

Federal Item Identification Guide (FIIG_4065)

00184

Item Naming Code (INC_4080)

23 Dec 1978

NIIN Assignment Date (DT_NIIN_ASGMT_2180)

X

Item Criticality (CRITL_CD_FIIG_3843)


The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.

4

Type of Item Identification (TYP_II_4820)


Partial Descriptive Item Identification (Type 1 Concept)

6

Reference / Partial Descriptive Method Reason Code (RPDMRC_4765)


An approved item name and FIIG may exist, but it has previously been established and documented that industry refuses to provide the technical data sufficient for preparation on a full descriptive method item identification based on policy, restricted or proprietary data rights, nonexistence of technical data, etc.

A

Demilitarization Code (DEMIL_CD_0167)


Non-MLI/ Non-SLI — Demilitarization not required.

P

Hazardous Material Indicator Code (HMIC_0865)


Indicates there is no information in the HMIRS; however, the NSN is in a FSC in Table II of Federal Standard 313 and a MSDS may be required by the user. The requirement for a MSDS is dependent on a hazard determination of the supplier or the intended end use of the product.

U

Precious Metals Indicator Code (PMIC_0802)


Precious Metal Content is unknown.


FLIS - SEG B - MOE RULE DATA | NSN 5930-01-069-7648 Submit RFQ
MOE RuleFormer MOEAMCAMSCNIMSCIMCIMC ActivityAACDSORCollaboratorsReceiversEffective Date
ZF
ZG
ZR
ZU
ZW
ZX
ZX011 Apr 1991
ZG011 Apr 1991
ZF011 Apr 1991
ZW011 Dec 1995
ZR011 Dec 2007
ZU011 Apr 2008
Code Definitions

FLIS - SEG C - REFERENCE NUMBER | NSN 5930-01-069-7648 Submit RFQ
RNFCRNCCRNVCDACRNAACRNSCRNJCSADCMSDSHCCReference NumberCAGE
43249ZD7105SD9V30BE  09353  
4529ZGD91373279  D2416   CAGE/D2416
523ZND91373279  F8224   CAGE/F8224
Code Definitions

4

Reference Number Format Code (RNFC_2920)


Number is totally in-the-clear (without modification) as originally configured by the manufacturer, design control activity, or supplier.

3

Reference Number Category Code (RNCC_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

2

Reference Number Variation Code (RNVC_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.

4

Document Availability Code (DAC_2640)


The reference number is represented by technical documentation other than a drawing and the documentation was available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number; however, the RNAAC cannot furnish the technical documentation.

9Z

Reference Number Action Activity Code (RNAAC_2900)


DLIS-K, Battle Creek, MI 49037-3084

D

Reference Number Status Code (RNSC_2923)


Procurement authority of the manufacturer and reference number have not yet been checked. NOTE: This code is to be allocated to reference numbers still requiring checks on procurement authority.

5

Reference Number Category Code (RNCC_2910)


Secondary Reference. Any additional number, other than a primary number (codes 1,2,3,4) informative reference (code 6) or vendor item drawing reference (code 7) assigned to an item of production or supply by a commercial or Government organization, which represents the same item of production or supply to which the National Stock Number (NSN) was assigned. The reference number may have had an RNCC of 1, 2, 3, 4 or 7 but has since been replaced in the item-of-supply concept of the NSN by another primary number.

9

Document Availability Code (DAC_2640)


The reference number is of the type for which an indication of document availability is not required.

ZG

Reference Number Action Activity Code (RNAAC_2900)


Germany

3

Document Availability Code (DAC_2640)


The reference number is represented by technical documentation other than a drawing and the documentation was available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number. The RNAAC will furnish the technical documentation upon request.

ZN

Reference Number Action Activity Code (RNAAC_2900)


Netherlands


FLIS - SEG G - FREIGHT DATA | NSN 5930-01-069-7648 Submit RFQ
IntegrityOriginatingHMCLCLWCCTCCSHCADCACCASHLTLNMFCNMFC Sub ItemUFCFreight DescriptionRail Variance
ZF
Code Definitions

ZF

Originating Activity Code (ORIG_ACTY_CD_4210)


France

Rail Variance

Rail Variance (RAIL_VARI_CD_4760)


No Variation. NMFC and UFCC Match.


FLIS - SEG M/V - CHARACTERISTICS DATA | NSN 5930-01-069-7648 Submit RFQ
MRCDecoded RequirementClear Text Reply
AFUSActuator Height0.480 INCHES NOMINAL
AFURActuator Diameter0.115 INCHES NOMINAL
AFUXActuator Position-Action RelationshipUP POSITION MOMENTARY AND DOWN POSITION MOMENTARY AND CENTER POSITION MAINTAINED
AFUQActuator StyleROUND
ADAUBody Height0.460 INCHES NOMINAL
ADAQBody Length0.620 INCHES NOMINAL
ADATBody Width0.302 INCHES NOMINAL
AAQLBody StyleBUSHING MOUNT
ABXDBushing Length0.280 INCHES NOMINAL
AFXEMaximum Voltage Rating In Volts20.0 DC
CRLDNonpile-Up Contact Arrangement1 POLE, DOUBLE THROW, TWO POSITIONS MOMENTARY SINGLE SWITCH UNIT
AKNAInclosure TypeFULLY INCLOSED
TTQYTerminal Type And Quantity3 PRINTED CIRCUIT


Back to Top
Back to Top