Manufacturer Part Number | RNCC | RNVC | Manufacturer Name | CAGE | |
---|---|---|---|---|---|
SW2910 | 3 - Design Control Reference | 2 - Production Item | ILLINOIS TOOL WORKS INC. | 04426 | ![]() |
0N500838-10 | 5 - Replaced / Discontinued | 2 - Production Item | NATIONAL SECURITY AGENCY | 98230 | ![]() |
Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.
Secondary Reference. Any additional number, other than a primary number (codes 1,2,3,4) informative reference (code 6) or vendor item drawing reference (code 7) assigned to an item of production or supply by a commercial or Government organization, which represents the same item of production or supply to which the National Stock Number (NSN) was assigned. The reference number may have had an RNCC of 1, 2, 3, 4 or 7 but has since been replaced in the item-of-supply concept of the NSN by another primary number.
A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.
FSG | FSC | NIIN | FIIG | INC | CRITICALITY | TYPE OF ITEM | MRC | DEMIL | HMIC | EDC | PMIC | ADPEC | DATE CREATED |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
59 | 5930 | 010840800 | A052B0 | 02134 | X | 1 | A | P | U | 8 Oct 1979 |
The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Full Descriptive Item Identification
Non-MLI/ Non-SLI — Demilitarization not required.
Indicates there is no information in the HMIRS; however, the NSN is in a FSC in Table II of Federal Standard 313 and a MSDS may be required by the user. The requirement for a MSDS is dependent on a hazard determination of the supplier or the intended end use of the product.
Precious Metal Content is unknown.
MOE Rule | Former MOE | AMC | AMSC | NIMSC | IMC | IMC Activity | AAC | DSOR | Collaborators | Receivers | Effective Date | |||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
N9BN | N9ND | 3 | H | Z | HD | HD | 1 Nov 2005 |
Acquire directly from the actual manufacturer, whether or not the prime contractor is the actual manufacturer.
The Government physically does not have in its possession sufficient, accurate, or legible data to purchase this part from other than current source(s). (NOTE: This code is applicable only to parts under immediate buy requirements and only as long as the deficiency is under review for resolution and appropriate recoding.) Valid AMCs: 1, 2, 3, 4 and 5.
Integrated Management: Relinquishment of Service management of an item in designated commodity oriented Federal Supply Classes to the IMM (FSC manager) for management.
Naval Inventory Control Point, Mechanicsburg, PA 17055-0788
Naval Inventory Control Point, Mechanicsburg, PA 17055-0788
RNFC | RNCC | RNVC | DAC | RNAAC | RNSC | RNJC | SADC | MSDS | HCC | Reference Number | CAGE | |
---|---|---|---|---|---|---|---|---|---|---|---|---|
3 | 2 | 5 | TX | SW2910 | 04426 | ![]() | ||||||
4 | 5 | 2 | 1 | TX | D | 0N500838-10 | 98230 | ![]() |
Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.
A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.
The reference number is represented by a drawing, but the drawing was not available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number.
Defense Supply Center Columbus, Columbus, OH 43218
Number is totally in-the-clear (without modification) as originally configured by the manufacturer, design control activity, or supplier.
Secondary Reference. Any additional number, other than a primary number (codes 1,2,3,4) informative reference (code 6) or vendor item drawing reference (code 7) assigned to an item of production or supply by a commercial or Government organization, which represents the same item of production or supply to which the National Stock Number (NSN) was assigned. The reference number may have had an RNCC of 1, 2, 3, 4 or 7 but has since been replaced in the item-of-supply concept of the NSN by another primary number.
The reference number is represented by a drawing and the drawing was available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number. The RNAAC will furnish the drawing upon request.
Procurement authority of the manufacturer and reference number have not yet been checked. NOTE: This code is to be allocated to reference numbers still requiring checks on procurement authority.
ISC | Originator | NIIN Status | Replaced / Replacement ISC | Replaced / Replacement Originator | Replacement NIIN Status | Replacement Date | Replaced / Replacement NSN | Decision Date |
---|---|---|---|---|---|---|---|---|
0 | TX | 0 | 8 Oct 1979 |
Items under the specification control of Defense Threat Reduction Agency (DTRA) or National Security Agency (NSA).
Defense Supply Center Columbus, Columbus, OH 43218
Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.
Integrity | Originating | HMC | LCL | WCC | TCC | SHC | ADC | ACC | ASH | LTL | NMFC | NMFC Sub Item | UFC | Freight Description | Rail Variance |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
TX | 72D | Z | 9 | A | H | Z | P | 061300 | X | 34410 | CIRCUIT-BREAKER-SWITCH-NOI |
Defense Supply Center Columbus, Columbus, OH 43218
Communications/Electronics, other than SIGINT/EW or COMSEC. Repair Parts and Components
No special type of cargo code applicable
No special handling required
Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
No special handling required.
77.5
No Variation. NMFC and UFCC Match.
Defense Logistics Agency, Enterprise Business Systems
TERMINAL ITEM. Identifies items in stock, but future procurement is not authorized. Requisitions may continue to be submitted until stocks are exhausted. Preferred item National Stock Number is normally provided by application of the phrase: When Exhausted Use (NSN). Requisitions will be submitted in accordance with IMM/Service requisitioning procedures as applicable.
Unclassified
No QUP
ARMY: This is a nonreparable item. If condemned or economically unserviceable, then dispose at the level authorized replace the item; MARINE CORPS: Nonreparable item. When unserviceable, condemn and dispose at the level indicated by the first digit of the maintenance code; NAVY: Special Program Consumables
Each - A numeric quantity of one item of supply. Do not use if a more specific term applies, such as kit, set, assortment, assembly, group, sheet, plate, strip or length.
TYPE I or TYPE II (Non-Deteriorative/No Shelf-Life) - An individual item of supply which is determined through an evaluation of technical test data and/or actual experience to be an item with a definite non-extendible period of shelf-life OR An individual item of supply having an assigned shelf-life time period that may be extended after completion of inspection/test/restorative action.
INSURANCE/NUMERIC STOCKAGE OBJECTIVE ITEM. Items which may be required occasionally or intermittently, and prudence requires that a nominal quantity of materiel be stocked due to the essentiality or the lead time of the item. 1. The item is centrally managed, stocked, and issued. 2. Requisitions will be submitted in accordance with IMM/Service requisitioning procedures.
1
Department of the Army
Department of the Navy
Defense Logistics Agency
Source | PICA / SICA | Packaging Category | Storage | Preservation | Clean/Dry | INT Qty | Unit Weight | Unit Size | Unit Pack Cube | Item Weight | Item Dims |
---|---|---|---|---|---|---|---|---|---|---|---|
P | P | ZZ | XXX |
Preservation Material | Wrapping Material | Cushioning / Dunnage | Cushioning Thickness | Unit Container | Intermediate Container | Unit Container Level | Special Marking | Level A Packing | Level B Packing | Minimal Packing | Optional Procedure |
---|---|---|---|---|---|---|---|---|---|---|---|
X | 00 | Q | Q | M |
Primary Inventory Control Activity (PICA)
Primary Inventory Control Activity (PICA)
See J.4.1.b
As required to protect the item or elements of the package
No special marking
Packing shall be accomplished in accordance with table C.II for the packing level specified. Closure sealing and reinforcement shall be in accordance with applicable specification for shipping container.
Packing shall be accomplished in accordance with table C-II for the packing level specified. Closure sealing and reinforcement shall be in accordance with the appropriate shipping container specification.
All packaging data is mandatory for compliance and no substitutions are permitted. Fast packs should be included in this category.
MRC | Decoded Requirement | Clear Text Reply |
---|---|---|
AGAV | End Item Identification | 5810-01-050-2501 01982 |
CTHF | Contact Load Current Rating | 125.0 MILLIAMPERES RESISTIVE LOAD DC AT SEA LEVEL AND 50.0 MILLIAMPERES INDUCTIVE LOAD DC AT SEA LEVEL |
CTHF | Contact Load Current Rating | 50.0 MILLIAMPERES RESISTIVE LOAD DC AT ALTITUDE AND 10.0 MILLIAMPERES INDUCTIVE LOAD DC AT ALTITUDE |
CTHF | Contact Load Current Rating | 75.0 MILLIAMPERES RESISTIVE LOAD AC AT SEA LEVEL |
CTHF | Contact Load Current Rating | 20.0 MILLIAMPERES RESISTIVE LOAD AC AT ALTITUDE |
CSHW | Contact Switching Action | BREAKS BEFORE MAKES SINGLE SECTION REAR |
CQMK | Contact Voltage Rating In Volts | 115.0 AC AT ALTITUDE |
CQMK | Contact Voltage Rating In Volts | 115.0 AC AT SEA LEVEL |
CQMK | Contact Voltage Rating In Volts | 28.0 DC AT ALTITUDE |
CQMK | Contact Voltage Rating In Volts | 28.0 DC AT SEA LEVEL |
CSMW | Detent Rotational Torque Range | +0.320/+1.700 INCH-POUNDS SINGLE ACTUATOR |
ABNB | First Flat Length | 0.250 INCHES NOMINAL SINGLE ACTUATOR |
ABFE | Hazardous Locations/Environmental Protection | EXPLOSION PROOF |
AXGY | Mounting Method | THREADED BUSHING W/PANEL SEAL SINGLE MOUNTING FACILITY |
CQJX | Nominal Thread Size | 0.250 INCHES SINGLE MOUNTING FACILITY |
AFDC | Nonturn Device Type | FLATTED BUSHING AT 3:00 O'CLOCK |
AFGA | Operating Temp Range | -65.0/+85.0 DEG CELSIUS |
AFBH | Individual Section Quantity | 1 |
AKPX | Pole Quantity | 2 SINGLE SECTION FRONT |
CQTH | Rotor Through Connection Quantity | 2 SINGLE SECTION |
ABWV | Shaft Diameter | 0.125 INCHES NOMINAL SINGLE ACTUATOR |
ABXF | Shaft Length | 0.312 INCHES NOMINAL SINGLE ACTUATOR |
CRSJ | Shaft Type | ROUND, PARALLEL FLATTED SINGLE ACTUATOR |
ADAV | Overall Diameter | 0.936 INCHES MAXIMUM |
ABHP | Overall Length | 1.562 INCHES NOMINAL |
FEAT | Special Features | SHAFT HAS NO. 2(0.086 IN.)-56 UNC-2B X 0.187 IN. MIN DEEP THD HOLE; SHAFT GROUNDED FOR RFI/EMI PROTECTION |
AKPY | Throw Quantity | 2 SINGLE SECTION REAR |
AATB | Width Between Flats | 0.094 INCHES NOMINAL SINGLE ACTUATOR |
STYL | Style Designator | TAP, CIRCULAR, BUSHING MOUNT |
CRJH | Switch Actuator Indexing Position Quantity | 2 SINGLE ACTUATOR |
CSLC | Switch Actuator Positioning Increment | 30.0 DEGREES SINGLE ACTUATOR |
CTDN | Switch Actuator Stop Device Type | FIXED STOP SINGLE ACTUATOR |
AJZE | Switch Contact Basic Design | NONPILE-UP SYMMETRICAL |
CSCF | Terminal Type | TAB, SOLDER LUG |
AAJD | Thread Class | 2A SINGLE MOUNTING FACILITY |
AASA | Thread Length | 0.250 INCHES NOMINAL SINGLE MOUNTING FACILITY |
THSD | Thread Series Designator | UNEF SINGLE MOUNTING FACILITY |