5930-01-094-1358

SWITCH SECTION,ROTARY


5930-01-094-1358 (5930010941358, 010941358)
Part Numbers (2 listings): 5024053401 | 5024-0534-00 |
Summary

FSG 59 / FSC 5930

DEMIL: A

DEMIL INT:

HMIC: P

Date Created: 3 May 1980

MSDS: None

Hazmat: None

Request a Quote


;



MASTER CROSS REFERENCE LIST (MCRL) | NSN 5930-01-094-1358 Submit RFQ
Manufacturer Part NumberRNCCRNVCManufacturer NameCAGE
50240534013 - Design Control Reference2 - Production ItemRIIMIC, LLC  12338      
5024-0534-005 - Replaced / Discontinued9 - No Longer UsedRIIMIC, LLC  12338      
Code Definitions

3 - Design Control Reference

Reference Number Category Code (DRN_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

5 - Replaced / Discontinued

Reference Number Category Code (DRN_2910)


Secondary Reference. Any additional number, other than a primary number (codes 1,2,3,4) informative reference (code 6) or vendor item drawing reference (code 7) assigned to an item of production or supply by a commercial or Government organization, which represents the same item of production or supply to which the National Stock Number (NSN) was assigned. The reference number may have had an RNCC of 1, 2, 3, 4 or 7 but has since been replaced in the item-of-supply concept of the NSN by another primary number.

2 - Production Item

Reference Number Variation Code (DRN_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.

9 - No Longer Used

Reference Number Variation Code (DRN_4780)


A specification, standard, or other reference number which is superseded, canceled, obsolete or discontinued and is coded Reference Number Category Code (RNCC) 5; a reference number for information only coded RNCC 6; or a reference number coded RNCC D.


FLIS - SEG A - IDENTIFICATION | NSN 5930-01-094-1358 Submit RFQ
FSGFSCNIINFIIGINCCRITICALITYTYPE OF ITEMMRCDEMILHMICEDCPMICADPECDATE CREATED
595930010941358A052B015315XKAPA3 May 1980
Code Definitions

59

Federal Supply Group (FSG_3994/FSC_WI_FSG_3996)


Electrical and Electronic Equipment Components

5930

Federal Supply Class (FSC_3994/FSC_WI_FSC_3996)


Switches

010941358

National Item Identification Number (NCB_CD_4130/I_I_NBR_4131)


NSN 5930-01-094-1358

A052B0

Federal Item Identification Guide (FIIG_4065)

15315

Item Naming Code (INC_4080)

3 May 1980

NIIN Assignment Date (DT_NIIN_ASGMT_2180)

X

Item Criticality (CRITL_CD_FIIG_3843)


The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.

K

Type of Item Identification (TYP_II_4820)


Full Descriptive - Reference Item Identification

A

Demilitarization Code (DEMIL_CD_0167)


Non-MLI/ Non-SLI — Demilitarization not required.

P

Hazardous Material Indicator Code (HMIC_0865)


Indicates there is no information in the HMIRS; however, the NSN is in a FSC in Table II of Federal Standard 313 and a MSDS may be required by the user. The requirement for a MSDS is dependent on a hazard determination of the supplier or the intended end use of the product.

A

Precious Metals Indicator Code (PMIC_0802)


Item does not contain Precious Metal.


FLIS - SEG B - MOE RULE DATA | NSN 5930-01-094-1358 Submit RFQ
MOE RuleFormer MOEAMCAMSCNIMSCIMCIMC ActivityAACDSORCollaboratorsReceiversEffective Date
YW011 Sep 1993
ZU011 Aug 1995
Code Definitions

FLIS - SEG C - REFERENCE NUMBER | NSN 5930-01-094-1358 Submit RFQ
RNFCRNCCRNVCDACRNAACRNSCRNJCSADCMSDSHCCReference NumberCAGE
326XG5024053401  12338  
1596XGB5024-0534-00  12338  
Code Definitions

3

Reference Number Category Code (RNCC_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

2

Reference Number Variation Code (RNVC_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.

6

Document Availability Code (DAC_2640)


The reference number is represented by technical documentation other than a drawing but the documentation was not available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number.

XG

Reference Number Action Activity Code (RNAAC_2900)


USCG Engineering Logistics Center, Baltimore, MD 21226-5000

1

Reference Number Format Code (RNFC_2920)


Number is formatted as configured on the originating document with the exception of the modification required in volume 2, chapter 2.9.Number is formatted as configured on the originating document with the exception of the modification required in volume 2, chapter 2.9 .

5

Reference Number Category Code (RNCC_2910)


Secondary Reference. Any additional number, other than a primary number (codes 1,2,3,4) informative reference (code 6) or vendor item drawing reference (code 7) assigned to an item of production or supply by a commercial or Government organization, which represents the same item of production or supply to which the National Stock Number (NSN) was assigned. The reference number may have had an RNCC of 1, 2, 3, 4 or 7 but has since been replaced in the item-of-supply concept of the NSN by another primary number.

9

Reference Number Variation Code (RNVC_4780)


A specification, standard, or other reference number which is superseded, canceled, obsolete or discontinued and is coded Reference Number Category Code (RNCC) 5; a reference number for information only coded RNCC 6; or a reference number coded RNCC D.

B

Reference Number Status Code (RNSC_2923)


Manufacturer and/or reference number are not authorized for procurement. NOTE: This code may be used for obsolete or informative reference numbers only.


FLIS - SEG E - ITEM STANDARDIZATION DATA | NSN 5930-01-094-1358 Submit RFQ
ISCOriginatorNIIN StatusReplaced / Replacement ISCReplaced / Replacement OriginatorReplacement NIIN StatusReplacement DateReplaced / Replacement NSNDecision Date
59703 May 1980
Code Definitions

5

Item Standardization Code (ISC_2650)


An item authorized for procurement that has not yet been subject to item standardization.

97

Originator of Standardization Decision (ORG_STDZN_DEC_9325)


DLIS-LFF, Battle Creek, MI 49037-3084

0

NIIN Status Code (NIIN_STAT_CD_2670)


Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.

3 May 1980

Standardization Decision Date (DT_STDZN_DEC_2300)


FLIS - SEG G - FREIGHT DATA | NSN 5930-01-094-1358 Submit RFQ
IntegrityOriginatingHMCLCLWCCTCCSHCADCACCASHLTLNMFCNMFC Sub ItemUFCFreight DescriptionRail Variance
XG
Code Definitions

XG

Originating Activity Code (ORIG_ACTY_CD_4210)


USCG Engineering Logistics Center, Baltimore, MD 21226-5000

Rail Variance

Rail Variance (RAIL_VARI_CD_4760)


No Variation. NMFC and UFCC Match.


FLIS - SEG M/V - CHARACTERISTICS DATA | NSN 5930-01-094-1358 Submit RFQ
MRCDecoded RequirementClear Text Reply
ADPRBody Thickness0.061 INCHES NOMINAL
CTHFContact Load Current Rating15.0 AMPERES RESISTIVE LOAD HIGHEST AC VOLTAGE RATING AT SEA LEVEL
CTHFContact Load Current Rating15.0 AMPERES RESISTIVE LOAD LOWEST AC VOLTAGE RATING AT SEA LEVEL
CQMKContact Voltage Rating In Volts115.0 LOWEST AC VOLTAGE RATING AT SEA LEVEL
CQMKContact Voltage Rating In Volts230.0 HIGHEST AC VOLTAGE RATING AT SEA LEVEL
AEJNDistance Between Mounting Facility Centers1.052 INCHES NOMINAL SINGLE MOUNTING FACILITY
AGAVEnd Item IdentificationRT1494P/URC116V
CQYJMounting Facility PatternTWO POSITION IN-LINE SINGLE MOUNTING FACILITY
AXGYMounting MethodUNTHREADED HOLE SINGLE MOUNTING FACILITY
STYLStyle DesignatorSWITCH SECTION, ROTARY
AKPXPole Quantity1 SINGLE SECTION FRONT
CQTHRotor Through Connection Quantity1 SINGLE SECTION
ADAVOverall Diameter1.600 INCHES NOMINAL
AKPYThrow Quantity10 SINGLE SECTION FRONT
AEBVUnthreaded Mounting Hole Diameter0.125 INCHES NOMINAL SINGLE MOUNTING FACILITY
AJZESwitch Contact Basic DesignNONPILE-UP SYMMETRICAL
CSCFTerminal TypeTAB, SOLDER LUG


Back to Top