Manufacturer Part Number | RNCC | RNVC | Manufacturer Name | CAGE | |
---|---|---|---|---|---|
M83504/04-005 | 2 - Definitive Specification or Standard Document | 2 - Production Item | MILITARY SPECIFICATIONS | 81349 | ![]() |
MIL-S-83504/4 | 4 - Non-Definitive Specification or Standard Document | 1 - Incomplete Part Number | MILITARY SPECIFICATIONS | 81349 | ![]() |
206-5 | C - Advisory Reference | 1 - Incomplete Part Number | CTS CORP | 71450 | ![]() |
SDP0-00501 | C - Advisory Reference | 1 - Incomplete Part Number | GIGA-TRONICS INCORPORATED | 58900 | ![]() |
206-1258 | C - Advisory Reference | 1 - Incomplete Part Number | CTS CORP OF CALIFORNIA | 11237 | ![]() |
206-1258 | C - Advisory Reference | 1 - Incomplete Part Number | CTS CORP OF CALIFORNIA | 11237 | ![]() |
206-5 | C - Advisory Reference | 1 - Incomplete Part Number | CTS CORP OF CALIFORNIA | 11237 | ![]() |
206-5 | C - Advisory Reference | 1 - Incomplete Part Number | CTS CORP OF CALIFORNIA | 11237 | ![]() |
CTS206-005 | C - Advisory Reference | 1 - Incomplete Part Number | CTS CORP OF CALIFORNIA | 11237 | ![]() |
CTS206-005 | C - Advisory Reference | 1 - Incomplete Part Number | CTS CORP OF CALIFORNIA | 11237 | ![]() |
3101-2159 | C - Advisory Reference | 1 - Incomplete Part Number | HEWLETT PACKARD CO | 28480 | ![]() |
3101-2159 | C - Advisory Reference | 1 - Incomplete Part Number | HEWLETT PACKARD CO | 28480 | ![]() |
3101-0403 | C - Advisory Reference | 1 - Incomplete Part Number | HEWLETT PACKARD CO | 28480 | ![]() |
3101-0403 | C - Advisory Reference | 1 - Incomplete Part Number | HEWLETT PACKARD CO | 28480 | ![]() |
117374 | C - Advisory Reference | 1 - Incomplete Part Number | SYSTRON-DONNER CORP | 52542 | ![]() |
4021678-5 | C - Advisory Reference | 1 - Incomplete Part Number | HONEYWELL INTERNATIONAL INC. | 07187 | ![]() |
4021678-5 | C - Advisory Reference | 1 - Incomplete Part Number | HONEYWELL INTERNATIONAL INC. | 07187 | ![]() |
Definitive Government Specification or Standard Designator Reference. A part number, style number, or type designator included in or developed in accordance with a Government specification or standard which has the effect of fully identifying an item of supply. This code shall also be used for a Government specification or standard which, although not including part numbers, style numbers, or type designators, covers a single item of upply. These reference numbers may be coded with Reference Number Variation Code (RNVC) 1 in accordance with volume 2, paragraph 2.9.2.n.(4).
Non-Definitive U.S. Government Specification or Standard Reference. Any Government specification or standard reference other than those indicated in code 2 as definitive references. This code shall be used for non-definitive Government specifications and standard references and non-definitive part numbers, type designators, and style numbers included therein which are coded with RNVC 1.
Advisory Reference. A number assigned to an item of production or supply not included in the item-of-supply concept to which the NSN has been assigned (e.g., an item that may have been used in the preproduction equipment design which has since been redesigned or replaced). Use of this RNCC is restricted to conditions where cross-reference is required to establish identification to an item of supply. Additionally, there is not direct relationship of the reference number to the NSN other than a Service/Agency individual decision. (RNCC shall be used only in conjunction with RNVC 1.
A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.
A design control or other reference number that does NOT identify an item of production without the use of additional information, or a specific part, type, or similar reference number does NOT identify or item of supply without the use of additional information.
FSG | FSC | NIIN | FIIG | INC | CRITICALITY | TYPE OF ITEM | MRC | DEMIL | HMIC | EDC | PMIC | ADPEC | DATE CREATED |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
59 | 5930 | 011008361 | A053A0 | 00400 | X | 1 | A | P | G | 0 | 14 Sep 1980 |
The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Full Descriptive Item Identification
Non-MLI/ Non-SLI — Demilitarization not required.
Indicates there is no information in the HMIRS; however, the NSN is in a FSC in Table II of Federal Standard 313 and a MSDS may be required by the user. The requirement for a MSDS is dependent on a hazard determination of the supplier or the intended end use of the product.
Item contains gold.
Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9)
MOE Rule | Former MOE | AMC | AMSC | NIMSC | IMC | IMC Activity | AAC | DSOR | Collaborators | Receivers | Effective Date | |||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
YJ01 | 1 Apr 1991 | |||||||||||||||||||||||||||||
ZC01 | 1 Apr 1991 | |||||||||||||||||||||||||||||
ZF01 | 1 Apr 1991 | |||||||||||||||||||||||||||||
ZG01 | 1 Apr 1991 | |||||||||||||||||||||||||||||
ZK01 | 1 Nov 1993 | |||||||||||||||||||||||||||||
ZA01 | 1 Jun 1995 | |||||||||||||||||||||||||||||
ZH01 | 1 Mar 1997 | |||||||||||||||||||||||||||||
ZW01 | 1 Nov 1998 | |||||||||||||||||||||||||||||
YB01 | 1 Jan 2000 | |||||||||||||||||||||||||||||
YA01 | 1 Dec 2001 | |||||||||||||||||||||||||||||
WP01 | 1 Dec 2003 | |||||||||||||||||||||||||||||
WB01 | 1 Feb 2005 | |||||||||||||||||||||||||||||
FXGX | FXTX | 1 | T | Z | SX | 1 Nov 2005 | ||||||||||||||||||||||||
N9BN | N9ND | 1 | T | Z | HD | HD | 1 Nov 2005 |
Suitable for competitive acquisition. Potential sources shall include dealers/distributors. If sources are limited to the prime contractor and a subcontractor, a competitive code shall not be assigned unless both sources are expected to compete independently for contracts for the part.
Acquisition of this part is controlled by QPL procedures. Valid AMCs: 1 and 2.
Integrated Management: Relinquishment of Service management of an item in designated commodity oriented Federal Supply Classes to the IMM (FSC manager) for management.
Oklahoma City Air Logistics Center, Tinker AFB, OK 73145-3043
Naval Inventory Control Point, Mechanicsburg, PA 17055-0788
Naval Inventory Control Point, Mechanicsburg, PA 17055-0788
RNFC | RNCC | RNVC | DAC | RNAAC | RNSC | RNJC | SADC | MSDS | HCC | Reference Number | CAGE | |
---|---|---|---|---|---|---|---|---|---|---|---|---|
4 | 2 | 2 | E | TX | D | M83504/04-005 | 81349 | ![]() | ||||
4 | 1 | E | TX | MIL-S-83504/4 | 81349 | ![]() | ||||||
C | 1 | 5 | TX | AW | 4021678-5 | 07187 | ![]() | |||||
4 | C | 1 | 5 | TX | D | AW | 206-1258 | 11237 | ![]() | |||
4 | C | 1 | 5 | TX | D | AW | 206-5 | 11237 | ![]() | |||
C | 1 | 6 | TX | AW | CTS206-005 | 11237 | ![]() | |||||
4 | C | 1 | 1 | TX | D | AW | 3101-0403 | 28480 | ![]() | |||
4 | C | 1 | 1 | TX | D | AW | 3101-2159 | 28480 | ![]() | |||
C | 1 | 5 | TX | AF | 117374 | 52542 | ![]() | |||||
C | 1 | 6 | ZZ | AC | SDP0-00501 | 58900 | ![]() | |||||
C | 1 | 6 | ZZ | AC | 206-5 | 71450 | ![]() |
Number is totally in-the-clear (without modification) as originally configured by the manufacturer, design control activity, or supplier.
Definitive Government Specification or Standard Designator Reference. A part number, style number, or type designator included in or developed in accordance with a Government specification or standard which has the effect of fully identifying an item of supply. This code shall also be used for a Government specification or standard which, although not including part numbers, style numbers, or type designators, covers a single item of upply. These reference numbers may be coded with Reference Number Variation Code (RNVC) 1 in accordance with volume 2, paragraph 2.9.2.n.(4).
A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.
The reference number is represented by engineering data other than an engineering drawing. The data is available for unlimited use and will be furnished by the activity identified by the RNAAC upon request.
Defense Supply Center Columbus, Columbus, OH 43218
Procurement authority of the manufacturer and reference number have not yet been checked. NOTE: This code is to be allocated to reference numbers still requiring checks on procurement authority.
Non-Definitive U.S. Government Specification or Standard Reference. Any Government specification or standard reference other than those indicated in code 2 as definitive references. This code shall be used for non-definitive Government specifications and standard references and non-definitive part numbers, type designators, and style numbers included therein which are coded with RNVC 1.
A design control or other reference number that does NOT identify an item of production without the use of additional information, or a specific part, type, or similar reference number does NOT identify or item of supply without the use of additional information.
Advisory Reference. A number assigned to an item of production or supply not included in the item-of-supply concept to which the NSN has been assigned (e.g., an item that may have been used in the preproduction equipment design which has since been redesigned or replaced). Use of this RNCC is restricted to conditions where cross-reference is required to establish identification to an item of supply. Additionally, there is not direct relationship of the reference number to the NSN other than a Service/Agency individual decision. (RNCC shall be used only in conjunction with RNVC 1.
The reference number is represented by a drawing, but the drawing was not available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number.
Air Force / Defense Logistics Agency
The reference number is represented by technical documentation other than a drawing but the documentation was not available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number.
The reference number is represented by a drawing and the drawing was available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number. The RNAAC will furnish the drawing upon request.
Defense Logistics Agency
USA
Navy
ISC | Originator | NIIN Status | Replaced / Replacement ISC | Replaced / Replacement Originator | Replacement NIIN Status | Replacement Date | Replaced / Replacement NSN | Decision Date |
---|---|---|---|---|---|---|---|---|
6 | TX | 0 | 18 Jan 1989 |
An item authorized for procurement that is in a specific Federal Supply Class (FSC) or item name grouping consisting primarily of items which are one-of-a-kind; therefore, little or no potential exists for elimination of items through formal item reduction studies.
Defense Supply Center Columbus, Columbus, OH 43218
Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.
Integrity | Originating | HMC | LCL | WCC | TCC | SHC | ADC | ACC | ASH | LTL | NMFC | NMFC Sub Item | UFC | Freight Description | Rail Variance |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
TX | 658 | Z | 9 | A | H | Z | W | 063250 | Z | 34410 | SWITCHES-AIR-BREAK |
Defense Supply Center Columbus, Columbus, OH 43218
Electical Appliances, Small
No special type of cargo code applicable
No special handling required
Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
No special handling required.
Variable Rating
No Variation. NMFC and UFCC Match.
Defense Logistics Agency, Enterprise Business Systems
INSURANCE/NUMERIC STOCKAGE OBJECTIVE ITEM. Items which may be required occasionally or intermittently, and prudence requires that a nominal quantity of materiel be stocked due to the essentiality or the lead time of the item. 1. The item is centrally managed, stocked, and issued. 2. Requisitions will be submitted in accordance with IMM/Service requisitioning procedures.
Unclassified
1
AIR FORCE ERRC XB3: Stock Fund (Except Munitions); DLA: This item has been reviewed and a determination made that the item cannot or should not be restored to a serviceable condition from an unserviceable condition; NAVY: 1I cog not stocked print on demand flat forms
Each - A numeric quantity of one item of supply. Do not use if a more specific term applies, such as kit, set, assortment, assembly, group, sheet, plate, strip or length.
TYPE I or TYPE II (Non-Deteriorative/No Shelf-Life) - An individual item of supply which is determined through an evaluation of technical test data and/or actual experience to be an item with a definite non-extendible period of shelf-life OR An individual item of supply having an assigned shelf-life time period that may be extended after completion of inspection/test/restorative action.
Department of the Air Force
Department of the Navy
Defense Logistics Agency
Source | PICA / SICA | Packaging Category | Storage | Preservation | Clean/Dry | INT Qty | Unit Weight | Unit Size | Unit Pack Cube | Item Weight | Item Dims |
---|---|---|---|---|---|---|---|---|---|---|---|
P | P | ZZ | XXX | 0.1 lbs | 0.001 cu ft |
Preservation Material | Wrapping Material | Cushioning / Dunnage | Cushioning Thickness | Unit Container | Intermediate Container | Unit Container Level | Special Marking | Level A Packing | Level B Packing | Minimal Packing | Optional Procedure |
---|---|---|---|---|---|---|---|---|---|---|---|
X | 00 | Q | Q | O |
Primary Inventory Control Activity (PICA)
Primary Inventory Control Activity (PICA)
See J.4.1.b
As required to protect the item or elements of the package
No special marking
Packing shall be accomplished in accordance with table C.II for the packing level specified. Closure sealing and reinforcement shall be in accordance with applicable specification for shipping container.
Packing shall be accomplished in accordance with table C-II for the packing level specified. Closure sealing and reinforcement shall be in accordance with the appropriate shipping container specification.
Options can be exercised as to specific method of preservation or DoD approved packaging materials to be used. However, basic preservation method shall be retained, supplemental data shall be complied with, and unit package dimensions shall not be increased by more than one inch. Equal or better protection shall be given the item and there shall be no increase in the package cost.
MRC | Decoded Requirement | Clear Text Reply |
---|---|---|
AFUS | Actuator Height | 0.040 INCHES NOMINAL |
AFGK | Actuator Length | 0.045 INCHES MINIMUM AND 0.065 INCHES MAXIMUM |
AFUX | Actuator Position-Action Relationship | UP POSITION MAINTAINED AND DOWN POSITION MAINTAINED |
AFUQ | Actuator Style | RECTANGULAR |
AFUT | Actuator Width | 0.055 INCHES MINIMUM AND 0.085 INCHES MAXIMUM |
ADAU | Body Height | 0.230 INCHES MINIMUM AND 0.300 INCHES MAXIMUM |
ADAQ | Body Length | 0.560 INCHES MINIMUM AND 0.600 INCHES MAXIMUM |
AAQL | Body Style | PRINTED CIRCUIT |
ADAT | Body Width | 0.370 INCHES MINIMUM AND 0.405 INCHES MAXIMUM |
ADTV | Case Material | PLASTIC |
CXQR | Contact Load Current Rating At Maximum Rated Voltage | 100.0 MILLIAMPERES RESISTIVE DC AND 25.0 MILLIAMPERES RESISTIVE DC |
AFXE | Maximum Voltage Rating In Volts | 6.0 DC AND 24.0 DC |
AXGY | Mounting Method | PRINTED CIRCUIT |
CRLD | Nonpile-Up Contact Arrangement | 1 POLE, SINGLE THROW, BOTH POSITIONS MAINTAINED 1ST SWITCH UNIT |
CRLD | Nonpile-Up Contact Arrangement | 1 POLE, SINGLE THROW, BOTH POSITIONS MAINTAINED 2ND SWITCH UNIT |
CRLD | Nonpile-Up Contact Arrangement | 1 POLE, SINGLE THROW, BOTH POSITIONS MAINTAINED 3RD SWITCH UNIT |
CRLD | Nonpile-Up Contact Arrangement | 1 POLE, SINGLE THROW, BOTH POSITIONS MAINTAINED 4TH SWITCH UNIT |
CRLD | Nonpile-Up Contact Arrangement | 1 POLE, SINGLE THROW, BOTH POSITIONS MAINTAINED 5TH SWITCH UNIT |
PMLC | Precious Material And Location | TERMINAL AND CONTACT SURFACES GOLD |
ABKW | Overall Height | 0.465 INCHES NOMINAL |
ABHP | Overall Length | 0.560 INCHES MINIMUM AND 0.600 INCHES MAXIMUM |
ABMK | Overall Width | 0.370 INCHES MINIMUM AND 0.405 INCHES MAXIMUM |
ZZZK | Specification/Standard Data | 81349-MIL-S-83504/4 GOVERNMENT SPECIFICATION |
AFCG | Switch Actuator Quantity | 5 |
TTQY | Terminal Type And Quantity | 10 PRINTED CIRCUIT |
TEST | Test Data Document | 81349-MIL-S-83504 SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL", "AVERAGE", "NOMINAL", ETC.). |