Manufacturer Part Number | RNCC | RNVC | Manufacturer Name | CAGE | |
---|---|---|---|---|---|
28066K | 3 - Design Control Reference | 2 - Production Item | ELECTRO SWITCH CORP. | 76854 | ![]() |
269-2613-280 | 7 - Vendor Item Drawing Reference | 2 - Production Item | ROCKWELL COLLINS, INC. | 13499 | ![]() |
Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.
Vendor Item Drawing Reference (formerly Specification Control Reference). The number assigned by a design activity to a drawing that is not item-identifying, but which delineates existing commercial or vendor-developed items meeting all engineering and test requirements specified, without imposing additional test/engineering requirements not normally provided by the vendor(s). Includes only those drawings which meet the definition for Vendor Item Drawing in MIL-STD 100. Vendor Item Drawing References are administrative control numbers and shall not be used as part identification numbers.
A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.
FSG | FSC | NIIN | FIIG | INC | CRITICALITY | TYPE OF ITEM | MRC | DEMIL | HMIC | EDC | PMIC | ADPEC | DATE CREATED |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
59 | 5930 | 011266771 | A052B0 | 15315 | X | 1 | A | P | U | 15 Feb 1982 |
The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Full Descriptive Item Identification
Non-MLI/ Non-SLI — Demilitarization not required.
Indicates there is no information in the HMIRS; however, the NSN is in a FSC in Table II of Federal Standard 313 and a MSDS may be required by the user. The requirement for a MSDS is dependent on a hazard determination of the supplier or the intended end use of the product.
Precious Metal Content is unknown.
MOE Rule | Former MOE | AMC | AMSC | NIMSC | IMC | IMC Activity | AAC | DSOR | Collaborators | Receivers | Effective Date | |||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
ZT01 | 1 Apr 1991 | |||||||||||||||||||||||||||||
ZW01 | 1 Nov 1998 | |||||||||||||||||||||||||||||
ZC01 | 1 May 2001 | |||||||||||||||||||||||||||||
YA01 | 1 Dec 2001 | |||||||||||||||||||||||||||||
ZG01 | 1 Jan 2015 |
RNFC | RNCC | RNVC | DAC | RNAAC | RNSC | RNJC | SADC | MSDS | HCC | Reference Number | CAGE | |
---|---|---|---|---|---|---|---|---|---|---|---|---|
1 | 3 | 2 | 2 | 9Z | D | 28066K | 76854 | ![]() | ||||
4 | 7 | 2 | 2 | 9Z | D | 269-2613-280 | 13499 | ![]() |
Number is formatted as configured on the originating document with the exception of the modification required in volume 2, chapter 2.9.Number is formatted as configured on the originating document with the exception of the modification required in volume 2, chapter 2.9 .
Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.
A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.
The reference number is represented by a drawing and the drawing was available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number; however, the RNAAC cannot furnish the drawing.
DLIS-K, Battle Creek, MI 49037-3084
Procurement authority of the manufacturer and reference number have not yet been checked. NOTE: This code is to be allocated to reference numbers still requiring checks on procurement authority.
Number is totally in-the-clear (without modification) as originally configured by the manufacturer, design control activity, or supplier.
Vendor Item Drawing Reference (formerly Specification Control Reference). The number assigned by a design activity to a drawing that is not item-identifying, but which delineates existing commercial or vendor-developed items meeting all engineering and test requirements specified, without imposing additional test/engineering requirements not normally provided by the vendor(s). Includes only those drawings which meet the definition for Vendor Item Drawing in MIL-STD 100. Vendor Item Drawing References are administrative control numbers and shall not be used as part identification numbers.
ISC | Originator | NIIN Status | Replaced / Replacement ISC | Replaced / Replacement Originator | Replacement NIIN Status | Replacement Date | Replaced / Replacement NSN | Decision Date |
---|---|---|---|---|---|---|---|---|
5 | 97 | 0 | 15 Feb 1982 |
An item authorized for procurement that has not yet been subject to item standardization.
DLIS-LFF, Battle Creek, MI 49037-3084
Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.
Integrity | Originating | HMC | LCL | WCC | TCC | SHC | ADC | ACC | ASH | LTL | NMFC | NMFC Sub Item | UFC | Freight Description | Rail Variance |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
ZG | P | 658 | Z | 9 | A | H | Z | P | 061300 | X | 34410 | CIRCUIT-BREAKER-SWITCH-NOI |
Germany
77.5
Electical Appliances, Small
No special type of cargo code applicable
No special handling required
Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
No special handling required.
No Variation. NMFC and UFCC Match.
MRC | Decoded Requirement | Clear Text Reply |
---|---|---|
ADPR | Body Thickness | 0.062 INCHES NOMINAL |
CTHF | Contact Load Current Rating | 30.0 MILLIAMPERES RESISTIVE LOAD HIGHEST AC VOLTAGE RATING AT SEA LEVEL |
CTHF | Contact Load Current Rating | 30.0 MILLIAMPERES RESISTIVE LOAD HIGHEST DC VOLTAGE RATING AT SEA LEVEL |
CTHF | Contact Load Current Rating | 300.0 MILLIAMPERES RESISTIVE LOAD LOWEST AC VOLTAGE RATING AT SEA LEVEL |
CTHF | Contact Load Current Rating | 300.0 MILLIAMPERES RESISTIVE LOAD LOWEST DC VOLTAGE RATING AT SEA LEVEL |
CSHW | Contact Switching Action | MAKES BEFORE BREAKS SINGLE SECTION FRONT |
CQMK | Contact Voltage Rating In Volts | 300.0 HIGHEST AC VOLTAGE RATING AT SEA LEVEL |
CQMK | Contact Voltage Rating In Volts | 300.0 HIGHEST DC VOLTAGE RATING AT ALTITUDE |
CQMK | Contact Voltage Rating In Volts | 30.0 LOWEST AC VOLTAGE RATING AT SEA LEVEL |
CQMK | Contact Voltage Rating In Volts | 30.0 LOWEST DC VOLTAGE RATING AT ALTITUDE |
CQYJ | Mounting Facility Pattern | TWO POSITION IN-LINE SINGLE MOUNTING FACILITY |
AXGY | Mounting Method | STRUT SINGLE MOUNTING FACILITY AND UNTHREADED HOLE SINGLE MOUNTING FACILITY |
AFGA | Operating Temp Range | -65.0/+100.0 DEG CELSIUS |
STYL | Style Designator | SWITCH SECTION, ROTARY |
AFDS | Longest Horizontal Distance Between Mounting Centers | 1.250 INCHES NOMINAL SINGLE MOUNTING FACILITY |
AKPX | Pole Quantity | 1 SINGLE SECTION REAR |
CQTH | Rotor Through Connection Quantity | 1 SINGLE SECTION |
ABKW | Overall Height | 1.593 INCHES MAXIMUM |
ABMK | Overall Width | 1.422 INCHES MAXIMUM |
AKPY | Throw Quantity | 12 SINGLE SECTION FRONT |
AEBV | Unthreaded Mounting Hole Diameter | 0.112 INCHES MINIMUM SINGLE MOUNTING FACILITY AND 0.115 INCHES MAXIMUM SINGLE MOUNTING FACILITY |
AJZE | Switch Contact Basic Design | NONPILE-UP SYMMETRICAL |
CSCF | Terminal Type | TAB, SOLDER LUG |