Manufacturer Part Number | RNCC | RNVC | Manufacturer Name | CAGE | |
---|---|---|---|---|---|
D22BA1BLCSP | 3 - Design Control Reference | 2 - Production Item | JANCO CORPORATION | 91812 | ![]() |
Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.
A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.
FSG | FSC | NIIN | FIIG | INC | CRITICALITY | TYPE OF ITEM | MRC | DEMIL | HMIC | EDC | PMIC | ADPEC | DATE CREATED |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
59 | 5930 | 011416901 | A052B0 | 62415 | X | 1 | A | P | U | 3 Nov 1982 |
The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Full Descriptive Item Identification
Non-MLI/ Non-SLI — Demilitarization not required.
Indicates there is no information in the HMIRS; however, the NSN is in a FSC in Table II of Federal Standard 313 and a MSDS may be required by the user. The requirement for a MSDS is dependent on a hazard determination of the supplier or the intended end use of the product.
Precious Metal Content is unknown.
MOE Rule | Former MOE | AMC | AMSC | NIMSC | IMC | IMC Activity | AAC | DSOR | Collaborators | Receivers | Effective Date | |||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
ZR01 | 1 Apr 1991 |
RNFC | RNCC | RNVC | DAC | RNAAC | RNSC | RNJC | SADC | MSDS | HCC | Reference Number | CAGE | |
---|---|---|---|---|---|---|---|---|---|---|---|---|
4 | 3 | 2 | 4 | 9Z | D | D22BA1BLCSP | 91812 | ![]() |
Number is totally in-the-clear (without modification) as originally configured by the manufacturer, design control activity, or supplier.
Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.
A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.
The reference number is represented by technical documentation other than a drawing and the documentation was available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number; however, the RNAAC cannot furnish the technical documentation.
DLIS-K, Battle Creek, MI 49037-3084
Procurement authority of the manufacturer and reference number have not yet been checked. NOTE: This code is to be allocated to reference numbers still requiring checks on procurement authority.
ISC | Originator | NIIN Status | Replaced / Replacement ISC | Replaced / Replacement Originator | Replacement NIIN Status | Replacement Date | Replaced / Replacement NSN | Decision Date |
---|---|---|---|---|---|---|---|---|
5 | 97 | 0 | 3 Nov 1982 |
An item authorized for procurement that has not yet been subject to item standardization.
DLIS-LFF, Battle Creek, MI 49037-3084
Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.
Integrity | Originating | HMC | LCL | WCC | TCC | SHC | ADC | ACC | ASH | LTL | NMFC | NMFC Sub Item | UFC | Freight Description | Rail Variance |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
ZR | P | 658 | Z | 9 | A | H | Z | P | 061300 | X | 34410 | CIRCUIT-BREAKER-SWITCH-NOI |
Italy
77.5
Electical Appliances, Small
No special type of cargo code applicable
No special handling required
Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
No special handling required.
No Variation. NMFC and UFCC Match.
MRC | Decoded Requirement | Clear Text Reply |
---|---|---|
AYDW | Actuator Type | DOUBLE PUSH BUTTON ALL ACTUATORS |
HUES | Color | BLACK SINGLE BODY |
HUES | Color | BLACK SINGLE INDICATOR BACKGROUND |
HUES | Color | WHITE SINGLE INDICATOR MARKING |
HUES | Color | CLEAR SINGLE LAMP |
CTZT | Contact Arrangement Truth Table | BCD, 1 POLE - 16 POSITIONS SINGLE SECTION |
CTHF | Contact Load Current Rating | 125.0 MILLIAMPERES RESISTIVE LOAD DC AT SEA LEVEL |
CTHF | Contact Load Current Rating | 125.0 MILLIAMPERES RESISTIVE LOAD AC AT SEA LEVEL |
CQMK | Contact Voltage Rating In Volts | 115.0 AC AT SEA LEVEL |
CQMK | Contact Voltage Rating In Volts | 28.0 DC AT SEA LEVEL |
AEJN | Distance Between Mounting Facility Centers | 1.562 INCHES NOMINAL SINGLE MOUNTING FACILITY |
CBBL | Features Provided | ILLUMINATED |
ABFE | Hazardous Locations/Environmental Protection | EXPLOSION PROOF |
CQYJ | Mounting Facility Pattern | TWO POSITION IN-LINE SINGLE MOUNTING FACILITY |
AXGY | Mounting Method | FLANGE SINGLE MOUNTING FACILITY AND THREADED HOLE SINGLE MOUNTING FACILITY |
CQJX | Nominal Thread Size | 0.086 INCHES SINGLE MOUNTING FACILITY |
STYL | Style Designator | RECTANGULAR INDICATING |
AFBH | Individual Section Quantity | 1 |
CTZF | Readout Indicator Marking | 0,1,2,3,4,5,6,7,8,9,10,11,12,13,14,15 SINGLE SECTION |
ABKW | Overall Height | 2.050 INCHES NOMINAL |
ABHP | Overall Length | 0.610 INCHES NOMINAL |
ABMK | Overall Width | 1.800 INCHES MAXIMUM |
CRJH | Switch Actuator Indexing Position Quantity | 16 ALL ACTUATORS |
CSCF | Terminal Type | PRINTED CIRCUIT |
AAJD | Thread Class | 2B SINGLE MOUNTING FACILITY |
THSD | Thread Series Designator | UNC SINGLE MOUNTING FACILITY |
CMLP | Thread Quantity Per Inch | 56 SINGLE MOUNTING FACILITY |