Manufacturer Part Number | RNCC | RNVC | Manufacturer Name | CAGE | |
---|---|---|---|---|---|
M83731/9-271 | 2 - Definitive Specification or Standard Document | 2 - Production Item | MILITARY SPECIFICATIONS | 81349 | ![]() |
MIL-DTL-83731 | 4 - Non-Definitive Specification or Standard Document | 1 - Incomplete Part Number | MILITARY SPECIFICATIONS | 81349 | ![]() |
927949 | 5 - Replaced / Discontinued | 1 - Incomplete Part Number | L-3 COMMUNICATIONS CORPORATION | 34228 | ![]() |
SF1SHX191 | 5 - Replaced / Discontinued | 9 - No Longer Used | DRS POWER & CONTROL TECHNOLOGIES, | 27192 | ![]() |
MIL-S-83731 | 5 - Replaced / Discontinued | 9 - No Longer Used | MILITARY SPECIFICATIONS | 81349 | ![]() |
MIL-S-83731/7 | 5 - Replaced / Discontinued | 9 - No Longer Used | MILITARY SPECIFICATIONS | 81349 | ![]() |
MIL-S-83731/9 | 5 - Replaced / Discontinued | 9 - No Longer Used | MILITARY SPECIFICATIONS | 81349 | ![]() |
M83731/7-271 | 5 - Replaced / Discontinued | 9 - No Longer Used | MILITARY SPECIFICATIONS | 81349 | ![]() |
7105SYQE | C - Advisory Reference | 1 - Incomplete Part Number | C AND K COMPONENTS INC | 09353 | ![]() |
7105SYQE | C - Advisory Reference | 1 - Incomplete Part Number | C AND K COMPONENTS INC | 09353 | ![]() |
A127SYZQ | C - Advisory Reference | 1 - Incomplete Part Number | EATON YALE LTD CUTLER-HAMMER | 08372 | ![]() |
SF1SHX191 | E - Replace Reference Number | 8 - Replacement NSN | EATON CORP | 55459 | ![]() |
Definitive Government Specification or Standard Designator Reference. A part number, style number, or type designator included in or developed in accordance with a Government specification or standard which has the effect of fully identifying an item of supply. This code shall also be used for a Government specification or standard which, although not including part numbers, style numbers, or type designators, covers a single item of upply. These reference numbers may be coded with Reference Number Variation Code (RNVC) 1 in accordance with volume 2, paragraph 2.9.2.n.(4).
Non-Definitive U.S. Government Specification or Standard Reference. Any Government specification or standard reference other than those indicated in code 2 as definitive references. This code shall be used for non-definitive Government specifications and standard references and non-definitive part numbers, type designators, and style numbers included therein which are coded with RNVC 1.
Secondary Reference. Any additional number, other than a primary number (codes 1,2,3,4) informative reference (code 6) or vendor item drawing reference (code 7) assigned to an item of production or supply by a commercial or Government organization, which represents the same item of production or supply to which the National Stock Number (NSN) was assigned. The reference number may have had an RNCC of 1, 2, 3, 4 or 7 but has since been replaced in the item-of-supply concept of the NSN by another primary number.
Advisory Reference. A number assigned to an item of production or supply not included in the item-of-supply concept to which the NSN has been assigned (e.g., an item that may have been used in the preproduction equipment design which has since been redesigned or replaced). Use of this RNCC is restricted to conditions where cross-reference is required to establish identification to an item of supply. Additionally, there is not direct relationship of the reference number to the NSN other than a Service/Agency individual decision. (RNCC shall be used only in conjunction with RNVC 1.
Replaced Reference Number. A manufacturerÆs part number, government specification/standard or other design control reference number that is superseded, discontinued or replaced resulting from a cancel-use action on a NSN which was recorded with ISC 3 or E. This reference number is automatically moved and this code is automatically assigned, do not submit for cataloging purposes.
A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.
A design control or other reference number that does NOT identify an item of production without the use of additional information, or a specific part, type, or similar reference number does NOT identify or item of supply without the use of additional information.
A specification, standard, or other reference number which is superseded, canceled, obsolete or discontinued and is coded Reference Number Category Code (RNCC) 5; a reference number for information only coded RNCC 6; or a reference number coded RNCC D.
A non-item-identifying reference number that is added to a replacement NSN as a result of a cancel-use action on a NSN recorded with ISC 3 or E. It is used to indentify the original item of supply/replaced item. This reference number is automatically moved and this code is automatically assigned, do not submit for cataloging purposes.
FSG | FSC | NIIN | FIIG | INC | CRITICALITY | TYPE OF ITEM | MRC | DEMIL | HMIC | EDC | PMIC | ADPEC | DATE CREATED |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
59 | 5930 | 011614508 | A053A0 | 00184 | X | 1 | A | P | V | 0 | 6 Sep 1983 |
The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Full Descriptive Item Identification
Non-MLI/ Non-SLI — Demilitarization not required.
Indicates there is no information in the HMIRS; however, the NSN is in a FSC in Table II of Federal Standard 313 and a MSDS may be required by the user. The requirement for a MSDS is dependent on a hazard determination of the supplier or the intended end use of the product.
Precious Metal type varies between manufacturers.
Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9)
MOE Rule | Former MOE | AMC | AMSC | NIMSC | IMC | IMC Activity | AAC | DSOR | Collaborators | Receivers | Effective Date | |||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
YB01 | 1 Apr 1991 | |||||||||||||||||||||||||||||
YJ01 | 1 Apr 1991 | |||||||||||||||||||||||||||||
ZA01 | 1 Apr 1991 | |||||||||||||||||||||||||||||
ZH01 | 1 Apr 1991 | |||||||||||||||||||||||||||||
ZS01 | 1 Apr 1991 | |||||||||||||||||||||||||||||
ZE01 | 1 Jan 1994 | |||||||||||||||||||||||||||||
ZK01 | 1 Jan 1994 | |||||||||||||||||||||||||||||
ZC01 | 1 Mar 1994 | |||||||||||||||||||||||||||||
ZT01 | 1 Oct 1997 | |||||||||||||||||||||||||||||
YA01 | 1 Oct 2000 | |||||||||||||||||||||||||||||
ZB01 | 1 Apr 2003 | |||||||||||||||||||||||||||||
WP01 | 1 Apr 2004 | |||||||||||||||||||||||||||||
ZN01 | 1 Oct 2004 | |||||||||||||||||||||||||||||
ZW01 | 1 Dec 2005 | |||||||||||||||||||||||||||||
ZU01 | 1 May 2006 | |||||||||||||||||||||||||||||
BGX1 | BTX1 | 1 | T | 1 Aug 2006 | ||||||||||||||||||||||||||
FXGX | FXTX | 1 | T | Z | SX | 1 Aug 2006 | ||||||||||||||||||||||||
G17X | G17E | 1 | T | 1 Aug 2006 | ||||||||||||||||||||||||||
G26X | G26E | 1 | T | 1 Aug 2006 | ||||||||||||||||||||||||||
MC49 | MC13 | 1 | T | Z | PA | 1 Aug 2006 | ||||||||||||||||||||||||
N9BN | N9ND | 1 | T | Z | KE | GT | HX | 1 Aug 2006 | ||||||||||||||||||||||
S911 | S007 | 1 | T | Z | XN | 1 Aug 2006 | ||||||||||||||||||||||||
ZP01 | 1 Jun 2009 | |||||||||||||||||||||||||||||
ZF01 | 1 Feb 2013 | |||||||||||||||||||||||||||||
A918 | 1 | T | Z | CT | CT | 1 May 2013 | ||||||||||||||||||||||||
YE01 | 1 Feb 2015 |
Suitable for competitive acquisition. Potential sources shall include dealers/distributors. If sources are limited to the prime contractor and a subcontractor, a competitive code shall not be assigned unless both sources are expected to compete independently for contracts for the part.
Acquisition of this part is controlled by QPL procedures. Valid AMCs: 1 and 2.
Integrated Management: Relinquishment of Service management of an item in designated commodity oriented Federal Supply Classes to the IMM (FSC manager) for management.
Oklahoma City Air Logistics Center, Tinker AFB, OK 73145-3043
Marine Corps Logistics Base, Albany, GA 31704-1128
Naval ICP, Philadelphia, PA 19111
National Security Agency, ATTN: L111, Fort George G. Meade, MD 20755-6000
U.S. Army Aviation and Missile Command (AIR) Redstone Arsenal, AL 35898-5230
Navy ICP, Mechanicsburg, PA 17055-0788
U.S. Army Aviation and Missile Command (AIR) Redstone Arsenal, AL 35898-5230
RNFC | RNCC | RNVC | DAC | RNAAC | RNSC | RNJC | SADC | MSDS | HCC | Reference Number | CAGE | |
---|---|---|---|---|---|---|---|---|---|---|---|---|
2 | 2 | 3 | TX | M83731/9-271 | 81349 | ![]() | ||||||
4 | 1 | E | ZZ | MIL-DTL-83731 | 81349 | ![]() | ||||||
5 | 1 | 5 | ZZ | 927949 | 34228 | ![]() | ||||||
5 | 9 | 3 | TX | B | MIL-S-83731 | 81349 | ![]() | |||||
5 | 9 | 3 | TX | B | MIL-S-83731/7 | 81349 | ![]() | |||||
5 | 9 | 4 | TX | B | MIL-S-83731/9 | 81349 | ![]() | |||||
1 | 5 | 9 | 3 | TX | B | SF1SHX191 | 27192 | ![]() | ||||
5 | 9 | 3 | TX | B | M83731/7-271 | 81349 | ![]() | |||||
C | 1 | 6 | ZZ | AC | A127SYZQ | 08372 | ![]() | |||||
C | 1 | 5 | TU | AW | 7105SYQE | 09353 | ![]() | |||||
E | 8 | 3 | TX | SF1SHX191 | 55459 | ![]() |
Definitive Government Specification or Standard Designator Reference. A part number, style number, or type designator included in or developed in accordance with a Government specification or standard which has the effect of fully identifying an item of supply. This code shall also be used for a Government specification or standard which, although not including part numbers, style numbers, or type designators, covers a single item of upply. These reference numbers may be coded with Reference Number Variation Code (RNVC) 1 in accordance with volume 2, paragraph 2.9.2.n.(4).
A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.
The reference number is represented by technical documentation other than a drawing and the documentation was available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number. The RNAAC will furnish the technical documentation upon request.
Defense Supply Center Columbus, Columbus, OH 43218
Non-Definitive U.S. Government Specification or Standard Reference. Any Government specification or standard reference other than those indicated in code 2 as definitive references. This code shall be used for non-definitive Government specifications and standard references and non-definitive part numbers, type designators, and style numbers included therein which are coded with RNVC 1.
A design control or other reference number that does NOT identify an item of production without the use of additional information, or a specific part, type, or similar reference number does NOT identify or item of supply without the use of additional information.
The reference number is represented by engineering data other than an engineering drawing. The data is available for unlimited use and will be furnished by the activity identified by the RNAAC upon request.
USA
Secondary Reference. Any additional number, other than a primary number (codes 1,2,3,4) informative reference (code 6) or vendor item drawing reference (code 7) assigned to an item of production or supply by a commercial or Government organization, which represents the same item of production or supply to which the National Stock Number (NSN) was assigned. The reference number may have had an RNCC of 1, 2, 3, 4 or 7 but has since been replaced in the item-of-supply concept of the NSN by another primary number.
The reference number is represented by a drawing, but the drawing was not available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number.
A specification, standard, or other reference number which is superseded, canceled, obsolete or discontinued and is coded Reference Number Category Code (RNCC) 5; a reference number for information only coded RNCC 6; or a reference number coded RNCC D.
Manufacturer and/or reference number are not authorized for procurement. NOTE: This code may be used for obsolete or informative reference numbers only.
The reference number is represented by technical documentation other than a drawing and the documentation was available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number; however, the RNAAC cannot furnish the technical documentation.
Number is formatted as configured on the originating document with the exception of the modification required in volume 2, chapter 2.9.Number is formatted as configured on the originating document with the exception of the modification required in volume 2, chapter 2.9 .
Advisory Reference. A number assigned to an item of production or supply not included in the item-of-supply concept to which the NSN has been assigned (e.g., an item that may have been used in the preproduction equipment design which has since been redesigned or replaced). Use of this RNCC is restricted to conditions where cross-reference is required to establish identification to an item of supply. Additionally, there is not direct relationship of the reference number to the NSN other than a Service/Agency individual decision. (RNCC shall be used only in conjunction with RNVC 1.
The reference number is represented by technical documentation other than a drawing but the documentation was not available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number.
Navy
AF Cataloging Agent DLIS-K, Battle Creek, MI 49037-3094
Air Force / Defense Logistics Agency
Replaced Reference Number. A manufacturerÆs part number, government specification/standard or other design control reference number that is superseded, discontinued or replaced resulting from a cancel-use action on a NSN which was recorded with ISC 3 or E. This reference number is automatically moved and this code is automatically assigned, do not submit for cataloging purposes.
A non-item-identifying reference number that is added to a replacement NSN as a result of a cancel-use action on a NSN recorded with ISC 3 or E. It is used to indentify the original item of supply/replaced item. This reference number is automatically moved and this code is automatically assigned, do not submit for cataloging purposes.
ISC | Originator | NIIN Status | Replaced / Replacement ISC | Replaced / Replacement Originator | Replacement NIIN Status | Replacement Date | Replaced / Replacement NSN | Decision Date |
---|---|---|---|---|---|---|---|---|
B | TX | 0 | 3 | TX | 1 | 15 Dec 1984 | 5930001065211 | 15 Nov 1990 |
B | TX | 0 | 3 | TX | 1 | 20 Dec 1980 | 5930003681403 | 15 Nov 1990 |
B | TX | 0 | 3 | TX | 1 | 10 Jun 1973 | 5930004557801 | 15 Nov 1990 |
B | TX | 0 | 3 | TX | 1 | 10 May 1969 | 5930008652015 | 15 Nov 1990 |
B | TX | 0 | 3 | TX | 1 | 11 Jan 1981 | 5930008949483 | 15 Nov 1990 |
B | TX | 0 | 3 | TX | 1 | 26 Aug 1983 | 5930010069668 | 15 Nov 1990 |
B | TX | 0 | 3 | TX | 1 | 17 Jun 1983 | 5930010305160 | 15 Nov 1990 |
B | TX | 0 | 3 | TX | 1 | 17 Jun 1983 | 5930010375058 | 15 Nov 1990 |
B | TX | 0 | 3 | TX | 1 | 17 Jun 1983 | 5930010739291 | 15 Nov 1990 |
B | TX | 0 | E | TX | 1 | 15 Nov 1990 | 5930011636258 | 15 Nov 1990 |
B | TX | 0 | 3 | TX | 0 | 8 May 2013 | 5930014381307 | 15 Nov 1990 |
A new item authorized for procurement, contained in a new or revised superseding specification or standard, that replaces prior items.
Defense Supply Center Columbus, Columbus, OH 43218
Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.
An item which, as a result of a formal item reduction study, is accepted as not authorized for procurement.
Represents an item for which a U.S. activity proposed cancelled-invalid or cancelled-use action or that the NIIN Status Code be changed to 9, and one or more NATO/FC did not concur in the proposal. See volume 4, chapter 4.9.Item is restricted to North Atlantic Treaty Organization/foreign country (NATO/FC) use only.Represents an item for which a U.S. activity proposed cancelled-invalid or cancelled-use action or that the NIIN Status Code be changed to 9, and one or more NATO/FC did not concur in the proposal. Item is restricted to North Atlantic Treaty Organization/foreign country (NATO/FC) use only.
An item no longer authorized for procurement which has been replaced by an item contained in a new or revised superseding specification or standard.
Integrity | Originating | HMC | LCL | WCC | TCC | SHC | ADC | ACC | ASH | LTL | NMFC | NMFC Sub Item | UFC | Freight Description | Rail Variance |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
TX | 72D | Z | 9 | A | H | Z | P | 061300 | X | 34410 | CIRCUIT-BREAKER-SWITCH-NOI |
Defense Supply Center Columbus, Columbus, OH 43218
Communications/Electronics, other than SIGINT/EW or COMSEC. Repair Parts and Components
No special type of cargo code applicable
No special handling required
Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
No special handling required.
77.5
No Variation. NMFC and UFCC Match.
Unit Price | MOE | SOS | AAC | CIIC | QUP | Reparability | UI | SLC |
---|---|---|---|---|---|---|---|---|
DA | SMS | D | U | 0 | A | EA | 0 | |
DF | SMS | D | U | 1 | N | EA | 0 | |
DM | SMS | D | U | 0 | Z | EA | 0 | |
DN | SMS | D | U | 0 | EA | 0 | ||
DS | SMS | D | U | 0 | N | EA | 0 |
Defense Logistics Agency, Enterprise Business Systems
DoD INTEGRATED MATERIEL-MANAGED, STOCKED, AND ISSUED. Issue, transfer, or shipment is not subject to specialized controls other than those imposed by the Integrated Materiel Manager/Service supply policy. 1. The item is centrally managed, stocked, and issued. 2. Requisitions must contain the fund citation required to acquire the item. Requisitions will be submitted in accordance with Integrated Materiel Manager(IMM)/Service requisitioning procedures.
Unclassified
No QUP
ARMY: Item requires special handling or condemnation procedures for specific reasons, such as precious metal content, high dollar value, critical material, or hazardous materiel. Refer to appropriate manuals or directives for specific instructions. MARINE CORPS: Item requires special handling/or condemnation procedures because of specific reasons (i.e., precious metal content, high dollar value, critical material, or hazardous material). Refer to appropriate manuals/directives for specific instructions. NAVY: Field Activity Control Items
Each - A numeric quantity of one item of supply. Do not use if a more specific term applies, such as kit, set, assortment, assembly, group, sheet, plate, strip or length.
TYPE I or TYPE II (Non-Deteriorative/No Shelf-Life) - An individual item of supply which is determined through an evaluation of technical test data and/or actual experience to be an item with a definite non-extendible period of shelf-life OR An individual item of supply having an assigned shelf-life time period that may be extended after completion of inspection/test/restorative action.
1
AIR FORCE ERRC XB3: Stock Fund (Except Munitions); DLA: This item has been reviewed and a determination made that the item cannot or should not be restored to a serviceable condition from an unserviceable condition; NAVY: 1I cog not stocked print on demand flat forms
ARMY: This is a nonreparable item. If condemned or economically unserviceable, then dispose at the level authorized replace the item; MARINE CORPS: Nonreparable item. When unserviceable, condemn and dispose at the level indicated by the first digit of the maintenance code; NAVY: Special Program Consumables
Department of the Army
Department of the Air Force
U.S. Marine Corps
Department of the Navy
Defense Logistics Agency
Source | PICA / SICA | Packaging Category | Storage | Preservation | Clean/Dry | INT Qty | Unit Weight | Unit Size | Unit Pack Cube | Item Weight | Item Dims |
---|---|---|---|---|---|---|---|---|---|---|---|
P | P | ZZ | XXX | 0.1 lbs | 0.002 cu ft |
Preservation Material | Wrapping Material | Cushioning / Dunnage | Cushioning Thickness | Unit Container | Intermediate Container | Unit Container Level | Special Marking | Level A Packing | Level B Packing | Minimal Packing | Optional Procedure |
---|---|---|---|---|---|---|---|---|---|---|---|
X | 00 | Q | Q | O |
Primary Inventory Control Activity (PICA)
Primary Inventory Control Activity (PICA)
See J.4.1.b
As required to protect the item or elements of the package
No special marking
Packing shall be accomplished in accordance with table C.II for the packing level specified. Closure sealing and reinforcement shall be in accordance with applicable specification for shipping container.
Packing shall be accomplished in accordance with table C-II for the packing level specified. Closure sealing and reinforcement shall be in accordance with the appropriate shipping container specification.
Options can be exercised as to specific method of preservation or DoD approved packaging materials to be used. However, basic preservation method shall be retained, supplemental data shall be complied with, and unit package dimensions shall not be increased by more than one inch. Equal or better protection shall be given the item and there shall be no increase in the package cost.
MRC | Decoded Requirement | Clear Text Reply |
---|---|---|
AFUS | Actuator Height | 0.410 INCHES NOMINAL |
AFUR | Actuator Diameter | 0.115 INCHES NOMINAL |
AFUX | Actuator Position-Action Relationship | UP POSITION MOMENTARY AND DOWN POSITION MOMENTARY AND CENTER POSITION MAINTAINED |
AFUQ | Actuator Style | ROUND |
ADAU | Body Height | 0.430 INCHES MAXIMUM |
ADAQ | Body Length | 0.510 INCHES MAXIMUM |
ADAT | Body Width | 0.275 INCHES MAXIMUM |
AAQL | Body Style | BUSHING MOUNT |
ABXD | Bushing Length | 0.300 INCHES NOMINAL |
CXQR | Contact Load Current Rating At Maximum Rated Voltage | 5.000 AMPERES RESISTIVE DC AND 2.000 AMPERES INDUCTIVE DC AND 1.000 AMPERES LAMP DC AND 5.000 AMPERES RESISTIVE AC AND 2.000 AMPERES INDUCTIVE AC AND 1.000 AMPERES LAMP AC |
AFXE | Maximum Voltage Rating In Volts | 125.0 AC AND 28.0 DC |
AXGY | Mounting Method | THREADED BUSHING |
CQJX | Nominal Thread Size | 0.250 INCHES |
CRLD | Nonpile-Up Contact Arrangement | 1 POLE, DOUBLE THROW, TWO POSITIONS MOMENTARY SINGLE SWITCH UNIT |
PMLC | Precious Material And Location | CONTACTS GOLD OR CONTACTS SILVER |
AKNA | Inclosure Type | FULLY INCLOSED |
TTQY | Terminal Type And Quantity | 3 TAB, SOLDER LUG |
TEST | Test Data Document | 81349-MIL-DTL-83731 SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL", "AVERAGE", "NOMINAL", ETC.). |
THSD | Thread Series Designator | UNS |
CMLP | Thread Quantity Per Inch | 40 |