5930-01-185-0424

SWITCH,PRESSURE-THERMOSTATIC


5930-01-185-0424 (5930011850424, 011850424)
Part Numbers (3 listings): AP21-1194 | HK02EC265 | P20EA-9 |
Summary

FSG 59 / FSC 5930

DEMIL: A

DEMIL INT: 1

HMIC: P

Date Created: 25 Jul 1984

Request a Quote


;



MASTER CROSS REFERENCE LIST (MCRL) | NSN 5930-01-185-0424 Submit RFQ
Manufacturer Part NumberRNCCRNVCManufacturer NameCAGE
AP21-11943 - Design Control Reference2 - Production ItemROBERTSHAW TENNESSEE/COOKEVILLE  80439      
HK02EC2655 - Replaced / Discontinued2 - Production ItemCARRIER CORPORATION  10855    CAGE 10855  
P20EA-95 - Replaced / Discontinued9 - No Longer UsedJOHNSON CONTROLS INC  92578      
Code Definitions

3 - Design Control Reference

Reference Number Category Code (DRN_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

5 - Replaced / Discontinued

Reference Number Category Code (DRN_2910)


Secondary Reference. Any additional number, other than a primary number (codes 1,2,3,4) informative reference (code 6) or vendor item drawing reference (code 7) assigned to an item of production or supply by a commercial or Government organization, which represents the same item of production or supply to which the National Stock Number (NSN) was assigned. The reference number may have had an RNCC of 1, 2, 3, 4 or 7 but has since been replaced in the item-of-supply concept of the NSN by another primary number.

2 - Production Item

Reference Number Variation Code (DRN_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.

9 - No Longer Used

Reference Number Variation Code (DRN_4780)


A specification, standard, or other reference number which is superseded, canceled, obsolete or discontinued and is coded Reference Number Category Code (RNCC) 5; a reference number for information only coded RNCC 6; or a reference number coded RNCC D.


FLIS - SEG A - IDENTIFICATION | NSN 5930-01-185-0424 Submit RFQ
FSGFSCNIINFIIGINCCRITICALITYTYPE OF ITEMMRCDEMILHMICEDCPMICADPECDATE CREATED
595930011850424A048B013383XKAPA25 Jul 1984
Code Definitions

59

Federal Supply Group (FSG_3994/FSC_WI_FSG_3996)


Electrical and Electronic Equipment Components

5930

Federal Supply Class (FSC_3994/FSC_WI_FSC_3996)


Switches

011850424

National Item Identification Number (NCB_CD_4130/I_I_NBR_4131)


NSN 5930-01-185-0424

A048B0

Federal Item Identification Guide (FIIG_4065)

13383

Item Naming Code (INC_4080)

25 Jul 1984

NIIN Assignment Date (DT_NIIN_ASGMT_2180)

X

Item Criticality (CRITL_CD_FIIG_3843)


The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.

K

Type of Item Identification (TYP_II_4820)


Full Descriptive - Reference Item Identification

A

Demilitarization Code (DEMIL_CD_0167)


Non-MLI/ Non-SLI — Demilitarization not required.

P

Hazardous Material Indicator Code (HMIC_0865)


Indicates there is no information in the HMIRS; however, the NSN is in a FSC in Table II of Federal Standard 313 and a MSDS may be required by the user. The requirement for a MSDS is dependent on a hazard determination of the supplier or the intended end use of the product.

A

Precious Metals Indicator Code (PMIC_0802)


Item does not contain Precious Metal.


FLIS - SEG B - MOE RULE DATA | NSN 5930-01-185-0424 Submit RFQ
MOE RuleFormer MOEAMCAMSCNIMSCIMCIMC ActivityAACDSORCollaboratorsReceiversEffective Date
ZE011 Apr 1991
ZN011 Apr 1991
YB011 Feb 1999
Code Definitions

FLIS - SEG E - ITEM STANDARDIZATION DATA | NSN 5930-01-185-0424 Submit RFQ
ISCOriginatorNIIN StatusReplaced / Replacement ISCReplaced / Replacement OriginatorReplacement NIIN StatusReplacement DateReplaced / Replacement NSNDecision Date
597025 Jul 1984
Code Definitions

5

Item Standardization Code (ISC_2650)


An item authorized for procurement that has not yet been subject to item standardization.

97

Originator of Standardization Decision (ORG_STDZN_DEC_9325)


DLIS-LFF, Battle Creek, MI 49037-3084

0

NIIN Status Code (NIIN_STAT_CD_2670)


Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.

25 Jul 1984

Standardization Decision Date (DT_STDZN_DEC_2300)


FLIS - SEG G - FREIGHT DATA | NSN 5930-01-185-0424 Submit RFQ
IntegrityOriginatingHMCLCLWCCTCCSHCADCACCASHLTLNMFCNMFC Sub ItemUFCFreight DescriptionRail Variance
Code Definitions

XF

Originating Activity Code (ORIG_ACTY_CD_4210)


Rail Variance

Rail Variance (RAIL_VARI_CD_4760)


No Variation. NMFC and UFCC Match.


FLIS - SEG M/V - CHARACTERISTICS DATA | NSN 5930-01-185-0424 Submit RFQ
MRCDecoded RequirementClear Text Reply
AGAVEnd Item IdentificationCONTROL BOX ASSEMBLY 30HK402024
ADAQBody Length2.090 INCHES NOMINAL
AEVVBulb Diameter0.250 INCHES NOMINAL
AEVUBulb Length2.060 INCHES NOMINAL
AEVTCapillary Tube Length24.0 INCHES NOMINAL
CQGBContact Action StimulusINCREASE
CTYCContact AdjustabilityACTUATION POINT NOT ADJUSTABLE
CTHFContact Load Current Rating16.0 AMPERES RESISTIVE LOAD FIRST VOLTAGE
CTHFContact Load Current Rating8.0 AMPERES RESISTIVE LOAD SECOND VOLTAGE
CTYXContact Stimulus Rating326.00 ACTUATION POINT MINIMUM POUNDS PER SQUARE INCH AND 346.00 ACTUATION POINT MAXIMUM POUNDS PER SQUARE INCH
CTZBContact Voltage Rating In Volts120.0 AC AT SEA LEVEL FIRST VOLTAGE
CTZBContact Voltage Rating In Volts240.0 AC AT SEA LEVEL SECOND VOLTAGE
AEJNDistance Between Mounting Facility Centers0.688 INCHES NOMINAL
CBMECubic Measure864.000 CUBIC INCHES
MEDAMedia For Which DesignedGAS OR LIQUID
CQYJMounting Facility PatternTWO POSITION IN-LINE
AXGYMounting MethodBRACKET
CRLDNonpile-Up Contact Arrangement1 POLE, DOUBLE THROW, BOTH POSITIONS MAINTAINED
AWTNOperating Temp Rating-20.0 DEG FAHRENHEIT MINIMUM AND 150.0 DEG FAHRENHEIT MAXIMUM
STYLStyle DesignatorRECTANGULAR
AJZCPressure Switch TypeGAGE
CQJBProof Pressure600.00 POUNDS PER SQUARE INCH GAGE
ABKWOverall Height2.960 INCHES NOMINAL
ABHPOverall Length2.090 INCHES NOMINAL
ABMKOverall Width1.120 INCHES NOMINAL
AKBYTemp Sensing Element TypeCAPILLARY TUBE
CSCFTerminal TypeQUICK DISCONNECT, MALE


Back to Top