5930-01-199-3812

SWITCH,THERMOSTATIC


5930-01-199-3812 (5930011993812, 011993812)
Part Number (1 listing): M1130115-142
Summary

FSG 59 / FSC 5930

DEMIL: A

DEMIL INT:

HMIC: P

Date Created: 21 Jan 1985

MSDS: None

Hazmat: None

Request a Quote


;



MASTER CROSS REFERENCE LIST (MCRL) | NSN 5930-01-199-3812 Submit RFQ
Manufacturer Part NumberRNCCRNVCManufacturer NameCAGE
M1130115-1423 - Design Control Reference2 - Production ItemSENSATA TECHNOLOGIES, INC  82647    CAGE 82647  
Code Definitions

3 - Design Control Reference

Reference Number Category Code (DRN_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

2 - Production Item

Reference Number Variation Code (DRN_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.


FLIS - SEG A - IDENTIFICATION | NSN 5930-01-199-3812 Submit RFQ
FSGFSCNIINFIIGINCCRITICALITYTYPE OF ITEMMRCDEMILHMICEDCPMICADPECDATE CREATED
595930011993812A048B000451X43APU21 Jan 1985
Code Definitions

59

Federal Supply Group (FSG_3994/FSC_WI_FSG_3996)


Electrical and Electronic Equipment Components

5930

Federal Supply Class (FSC_3994/FSC_WI_FSC_3996)


Switches

011993812

National Item Identification Number (NCB_CD_4130/I_I_NBR_4131)


NSN 5930-01-199-3812

A048B0

Federal Item Identification Guide (FIIG_4065)

00451

Item Naming Code (INC_4080)

21 Jan 1985

NIIN Assignment Date (DT_NIIN_ASGMT_2180)

X

Item Criticality (CRITL_CD_FIIG_3843)


The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.

4

Type of Item Identification (TYP_II_4820)


Partial Descriptive Item Identification (Type 1 Concept)

3

Reference / Partial Descriptive Method Reason Code (RPDMRC_4765)


An approved item name and FIIG exist but the item involved is so unique in design that it cannot be fully described in accordance with the FIIG.

A

Demilitarization Code (DEMIL_CD_0167)


Non-MLI/ Non-SLI — Demilitarization not required.

P

Hazardous Material Indicator Code (HMIC_0865)


Indicates there is no information in the HMIRS; however, the NSN is in a FSC in Table II of Federal Standard 313 and a MSDS may be required by the user. The requirement for a MSDS is dependent on a hazard determination of the supplier or the intended end use of the product.

U

Precious Metals Indicator Code (PMIC_0802)


Precious Metal Content is unknown.


FLIS - SEG B - MOE RULE DATA | NSN 5930-01-199-3812 Submit RFQ
MOE RuleFormer MOEAMCAMSCNIMSCIMCIMC ActivityAACDSORCollaboratorsReceiversEffective Date
ZF011 Apr 1991
ZG011 Apr 1991
Code Definitions

FLIS - SEG C - REFERENCE NUMBER | NSN 5930-01-199-3812 Submit RFQ
RNFCRNCCRNVCDACRNAACRNSCRNJCSADCMSDSHCCReference NumberCAGE
3269ZDM1130115-142  82647   CAGE/82647
Code Definitions

3

Reference Number Category Code (RNCC_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

2

Reference Number Variation Code (RNVC_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.

6

Document Availability Code (DAC_2640)


The reference number is represented by technical documentation other than a drawing but the documentation was not available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number.

9Z

Reference Number Action Activity Code (RNAAC_2900)


DLIS-K, Battle Creek, MI 49037-3084

D

Reference Number Status Code (RNSC_2923)


Procurement authority of the manufacturer and reference number have not yet been checked. NOTE: This code is to be allocated to reference numbers still requiring checks on procurement authority.


FLIS - SEG E - ITEM STANDARDIZATION DATA | NSN 5930-01-199-3812 Submit RFQ
ISCOriginatorNIIN StatusReplaced / Replacement ISCReplaced / Replacement OriginatorReplacement NIIN StatusReplacement DateReplaced / Replacement NSNDecision Date
597021 Jan 1985
Code Definitions

5

Item Standardization Code (ISC_2650)


An item authorized for procurement that has not yet been subject to item standardization.

97

Originator of Standardization Decision (ORG_STDZN_DEC_9325)


DLIS-LFF, Battle Creek, MI 49037-3084

0

NIIN Status Code (NIIN_STAT_CD_2670)


Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.

21 Jan 1985

Standardization Decision Date (DT_STDZN_DEC_2300)


FLIS - SEG G - FREIGHT DATA | NSN 5930-01-199-3812 Submit RFQ
IntegrityOriginatingHMCLCLWCCTCCSHCADCACCASHLTLNMFCNMFC Sub ItemUFCFreight DescriptionRail Variance
ZG
Code Definitions

ZG

Originating Activity Code (ORIG_ACTY_CD_4210)


Germany

Rail Variance

Rail Variance (RAIL_VARI_CD_4760)


No Variation. NMFC and UFCC Match.


FLIS - SEG M/V - CHARACTERISTICS DATA | NSN 5930-01-199-3812 Submit RFQ
MRCDecoded RequirementClear Text Reply
ADAUBody Height0.364 INCHES NOMINAL
CQGBContact Action StimulusINCREASE
CTYCContact AdjustabilityDEACTUATION POINT NOT ADJUSTABLE AND ACTUATION POINT NOT ADJUSTABLE
CTHFContact Load Current Rating6.0 AMPERES RESISTIVE LOAD SECOND VOLTAGE
CTHFContact Load Current Rating7.0 AMPERES RESISTIVE LOAD FIRST VOLTAGE
CTHFContact Load Current Rating3.0 AMPERES RESISTIVE LOAD THIRD VOLTAGE
CTYXContact Stimulus Rating130.00 ACTUATION POINT MAXIMUM DEGREES FAHRENHEIT AND 115.00 DEACTUATION POINT MINIMUM DEGREES FAHRENHEIT
CTZBContact Voltage Rating In Volts125.0 AC AT SEA LEVEL SECOND VOLTAGE
CTZBContact Voltage Rating In Volts250.0 AC AT SEA LEVEL THIRD VOLTAGE
CTZBContact Voltage Rating In Volts30.0 DC AT SEA LEVEL FIRST VOLTAGE
CRLDNonpile-Up Contact Arrangement1 POLE, SINGLE THROW, BOTH POSITIONS MAINTAINED
AWTNOperating Temp Rating-80.0 DEG FAHRENHEIT MINIMUM AND 550.0 DEG FAHRENHEIT MAXIMUM
ADAVOverall Diameter0.640 INCHES NOMINAL
ABKWOverall Height0.607 INCHES NOMINAL
FEATSpecial FeaturesMOUNTING METHOD: ANY ACCEPTABLE; MEDIA FOR WICH DESIGNED: ANY ACCEPTABLE; STYLE: DISC,CLAMP MOUNT - NO. 9F OF OLD FIIG A048A0
AKBYTemp Sensing Element TypeDISC
CSCFTerminal TypeTAB, SOLDER LUG