Manufacturer Part Number | RNCC | RNVC | Manufacturer Name | CAGE | |
---|---|---|---|---|---|
63C515557P1 | 3 - Design Control Reference | 2 - Production Item | LOCKHEED MARTIN CORPORATION | 16331 | ![]() |
24912LJ | 5 - Replaced / Discontinued | 2 - Production Item | ELECTRO SWITCH CORP. | 82121 | ![]() |
Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.
Secondary Reference. Any additional number, other than a primary number (codes 1,2,3,4) informative reference (code 6) or vendor item drawing reference (code 7) assigned to an item of production or supply by a commercial or Government organization, which represents the same item of production or supply to which the National Stock Number (NSN) was assigned. The reference number may have had an RNCC of 1, 2, 3, 4 or 7 but has since been replaced in the item-of-supply concept of the NSN by another primary number.
A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.
FSG | FSC | NIIN | FIIG | INC | CRITICALITY | TYPE OF ITEM | MRC | DEMIL | HMIC | EDC | PMIC | ADPEC | DATE CREATED |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
59 | 5930 | 012339216 | A052B0 | 02134 | X | 1 | A | P | A | 5 Jun 1986 |
The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Full Descriptive Item Identification
Non-MLI/ Non-SLI — Demilitarization not required.
Indicates there is no information in the HMIRS; however, the NSN is in a FSC in Table II of Federal Standard 313 and a MSDS may be required by the user. The requirement for a MSDS is dependent on a hazard determination of the supplier or the intended end use of the product.
Item does not contain Precious Metal.
MOE Rule | Former MOE | AMC | AMSC | NIMSC | IMC | IMC Activity | AAC | DSOR | Collaborators | Receivers | Effective Date | |||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
N9BN | N9ND | 1 | R | Z | HD | HD | 1 Jul 2005 |
Suitable for competitive acquisition. Potential sources shall include dealers/distributors. If sources are limited to the prime contractor and a subcontractor, a competitive code shall not be assigned unless both sources are expected to compete independently for contracts for the part.
The data or the rights to use the data needed to purchase this part from additional sources are not owned by the Government and it has been determined that it is uneconomical to purchase them. Valid AMCs: 1, 2, 3, 4 and 5.
Integrated Management: Relinquishment of Service management of an item in designated commodity oriented Federal Supply Classes to the IMM (FSC manager) for management.
Naval Inventory Control Point, Mechanicsburg, PA 17055-0788
Naval Inventory Control Point, Mechanicsburg, PA 17055-0788
RNFC | RNCC | RNVC | DAC | RNAAC | RNSC | RNJC | SADC | MSDS | HCC | Reference Number | CAGE | |
---|---|---|---|---|---|---|---|---|---|---|---|---|
3 | 2 | 5 | TX | 63C515557P1 | 16331 | ![]() | ||||||
5 | 2 | 5 | TX | 24912LJ | 82121 | ![]() |
Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.
A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.
The reference number is represented by a drawing, but the drawing was not available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number.
Defense Supply Center Columbus, Columbus, OH 43218
Secondary Reference. Any additional number, other than a primary number (codes 1,2,3,4) informative reference (code 6) or vendor item drawing reference (code 7) assigned to an item of production or supply by a commercial or Government organization, which represents the same item of production or supply to which the National Stock Number (NSN) was assigned. The reference number may have had an RNCC of 1, 2, 3, 4 or 7 but has since been replaced in the item-of-supply concept of the NSN by another primary number.
ISC | Originator | NIIN Status | Replaced / Replacement ISC | Replaced / Replacement Originator | Replacement NIIN Status | Replacement Date | Replaced / Replacement NSN | Decision Date |
---|---|---|---|---|---|---|---|---|
5 | 97 | 0 | 5 Jun 1986 |
An item authorized for procurement that has not yet been subject to item standardization.
DLIS-LFF, Battle Creek, MI 49037-3084
Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.
Integrity | Originating | HMC | LCL | WCC | TCC | SHC | ADC | ACC | ASH | LTL | NMFC | NMFC Sub Item | UFC | Freight Description | Rail Variance |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
TX | 72D | Z | 9 | A | H | Z | P | 061300 | X | 34410 | CIRCUIT-BREAKER-SWITCH-NOI |
Defense Supply Center Columbus, Columbus, OH 43218
Communications/Electronics, other than SIGINT/EW or COMSEC. Repair Parts and Components
No special type of cargo code applicable
No special handling required
Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
No special handling required.
77.5
No Variation. NMFC and UFCC Match.
Defense Logistics Agency, Enterprise Business Systems
NOT STOCKED, CENTRALLY PROCURED # (NON-STOCKED ITEMS) IMM/Service centrally managed but not stocked item. Procurement will be initiated only after receipt of a requisition.
Unclassified
1
Each - A numeric quantity of one item of supply. Do not use if a more specific term applies, such as kit, set, assortment, assembly, group, sheet, plate, strip or length.
TYPE I or TYPE II (Non-Deteriorative/No Shelf-Life) - An individual item of supply which is determined through an evaluation of technical test data and/or actual experience to be an item with a definite non-extendible period of shelf-life OR An individual item of supply having an assigned shelf-life time period that may be extended after completion of inspection/test/restorative action.
Department of the Navy
Defense Logistics Agency
Source | PICA / SICA | Packaging Category | Storage | Preservation | Clean/Dry | INT Qty | Unit Weight | Unit Size | Unit Pack Cube | Item Weight | Item Dims |
---|---|---|---|---|---|---|---|---|---|---|---|
P | P | ZZ | XXX |
Preservation Material | Wrapping Material | Cushioning / Dunnage | Cushioning Thickness | Unit Container | Intermediate Container | Unit Container Level | Special Marking | Level A Packing | Level B Packing | Minimal Packing | Optional Procedure |
---|---|---|---|---|---|---|---|---|---|---|---|
X | 00 | Q | Q | O |
Primary Inventory Control Activity (PICA)
Primary Inventory Control Activity (PICA)
See J.4.1.b
As required to protect the item or elements of the package
No special marking
Packing shall be accomplished in accordance with table C.II for the packing level specified. Closure sealing and reinforcement shall be in accordance with applicable specification for shipping container.
Packing shall be accomplished in accordance with table C-II for the packing level specified. Closure sealing and reinforcement shall be in accordance with the appropriate shipping container specification.
Options can be exercised as to specific method of preservation or DoD approved packaging materials to be used. However, basic preservation method shall be retained, supplemental data shall be complied with, and unit package dimensions shall not be increased by more than one inch. Equal or better protection shall be given the item and there shall be no increase in the package cost.
MRC | Decoded Requirement | Clear Text Reply |
---|---|---|
CTHF | Contact Load Current Rating | 0.4 AMPERES RESISTIVE LOAD DC AT SEA LEVEL |
CTHF | Contact Load Current Rating | 20.0 AMPERES RESISTIVE LOAD LOWEST AC VOLTAGE RATING AT SEA LEVEL |
CTHF | Contact Load Current Rating | 5.0 AMPERES RESISTIVE LOAD HIGHEST AC VOLTAGE RATING AT SEA LEVEL |
CSHW | Contact Switching Action | BREAKS BEFORE MAKES 11TH SECTION PERIPHERY |
CSHW | Contact Switching Action | BREAKS BEFORE MAKES 12TH SECTION PERIPHERY |
CSHW | Contact Switching Action | BREAKS BEFORE MAKES 10TH SECTION PERIPHERY |
CSHW | Contact Switching Action | BREAKS BEFORE MAKES 4TH SECTION PERIPHERY |
CSHW | Contact Switching Action | BREAKS BEFORE MAKES 5TH SECTION PERIPHERY |
CSHW | Contact Switching Action | BREAKS BEFORE MAKES 6TH SECTION PERIPHERY |
CSHW | Contact Switching Action | BREAKS BEFORE MAKES 7TH SECTION PERIPHERY |
CSHW | Contact Switching Action | BREAKS BEFORE MAKES 3RD SECTION PERIPHERY |
CSHW | Contact Switching Action | BREAKS BEFORE MAKES 8TH SECTION PERIPHERY |
CSHW | Contact Switching Action | BREAKS BEFORE MAKES 9TH SECTION PERIPHERY |
CSHW | Contact Switching Action | MAKES BEFORE BREAKS 1ST SECTION PERIPHERY |
CSHW | Contact Switching Action | MAKES BEFORE BREAKS 2ND SECTION PERIPHERY |
CQMK | Contact Voltage Rating In Volts | 125.0 LOWEST AC VOLTAGE RATING AT SEA LEVEL |
CQMK | Contact Voltage Rating In Volts | 355.0 DC AT SEA LEVEL |
CQMK | Contact Voltage Rating In Volts | 500.0 HIGHEST AC VOLTAGE RATING AT SEA LEVEL |
CBBL | Features Provided | ACTUATOR KNOB |
CQYJ | Mounting Facility Pattern | ISOSCELES TRIANGLE 1ST MOUNTING FACILITY |
AXGY | Mounting Method | BRACKET 1ST MOUNTING FACILITY AND THREADED HOLE 1ST MOUNTING FACILITY |
AXGY | Mounting Method | THREADED BUSHING 2ND MOUNTING FACILITY |
CQJX | Nominal Thread Size | 0.625 INCHES 2ND MOUNTING FACILITY |
CQJX | Nominal Thread Size | 0.190 INCHES 1ST MOUNTING FACILITY |
AFBH | Individual Section Quantity | 12 |
AFDV | Longest Vertical Distance Between Mounting Centers | 2.180 INCHES NOMINAL 1ST MOUNTING FACILITY |
AFDS | Longest Horizontal Distance Between Mounting Centers | 2.000 INCHES NOMINAL 1ST MOUNTING FACILITY |
AFDT | Shortest Horizontal Distance Between Mounting Centers | 1.000 INCHES NOMINAL 1ST MOUNTING FACILITY |
ABKW | Overall Height | 3.250 INCHES NOMINAL |
ABHP | Overall Length | 12.190 INCHES NOMINAL |
ABMK | Overall Width | 3.250 INCHES NOMINAL |
THSD | Thread Series Designator | UNEF 2ND MOUNTING FACILITY |
THSD | Thread Series Designator | UNF 1ST MOUNTING FACILITY |
STYL | Style Designator | TAP, CIRCUIT SELECTOR |
CRJH | Switch Actuator Indexing Position Quantity | 4 SINGLE ACTUATOR |
CSLC | Switch Actuator Positioning Increment | 45.0 DEGREES SINGLE ACTUATOR |
AJZE | Switch Contact Basic Design | NONPILE-UP NONSYMMETRICAL |
CSCF | Terminal Type | SCREW |
AAJD | Thread Class | 2A 2ND MOUNTING FACILITY |
AAJD | Thread Class | 2B 1ST MOUNTING FACILITY |
AASA | Thread Length | 0.375 INCHES NOMINAL 2ND MOUNTING FACILITY |