5930-01-258-5802

SWITCH,THERMOSTATIC


5930-01-258-5802 (5930012585802, 012585802)
Part Number (1 listing): M1300272282
Summary

FSG 59 / FSC 5930

DEMIL: A

DEMIL INT:

HMIC: P

Date Created: 4 Jul 1987

MSDS: None

Hazmat: None

Request a Quote


;



MASTER CROSS REFERENCE LIST (MCRL) | NSN 5930-01-258-5802 Submit RFQ
Manufacturer Part NumberRNCCRNVCManufacturer NameCAGE
M13002722823 - Design Control Reference2 - Production ItemSENSATA TECHNOLOGIES, INC  82647    CAGE 82647  
Code Definitions

3 - Design Control Reference

Reference Number Category Code (DRN_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

2 - Production Item

Reference Number Variation Code (DRN_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.


FLIS - SEG A - IDENTIFICATION | NSN 5930-01-258-5802 Submit RFQ
FSGFSCNIINFIIGINCCRITICALITYTYPE OF ITEMMRCDEMILHMICEDCPMICADPECDATE CREATED
595930012585802A048B000451X1APS4 Jul 1987
Code Definitions

59

Federal Supply Group (FSG_3994/FSC_WI_FSG_3996)


Electrical and Electronic Equipment Components

5930

Federal Supply Class (FSC_3994/FSC_WI_FSC_3996)


Switches

012585802

National Item Identification Number (NCB_CD_4130/I_I_NBR_4131)


NSN 5930-01-258-5802

A048B0

Federal Item Identification Guide (FIIG_4065)

00451

Item Naming Code (INC_4080)

4 Jul 1987

NIIN Assignment Date (DT_NIIN_ASGMT_2180)

X

Item Criticality (CRITL_CD_FIIG_3843)


The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.

1

Type of Item Identification (TYP_II_4820)


Full Descriptive Item Identification

A

Demilitarization Code (DEMIL_CD_0167)


Non-MLI/ Non-SLI — Demilitarization not required.

P

Hazardous Material Indicator Code (HMIC_0865)


Indicates there is no information in the HMIRS; however, the NSN is in a FSC in Table II of Federal Standard 313 and a MSDS may be required by the user. The requirement for a MSDS is dependent on a hazard determination of the supplier or the intended end use of the product.

S

Precious Metals Indicator Code (PMIC_0802)


Item contains silver.


FLIS - SEG B - MOE RULE DATA | NSN 5930-01-258-5802 Submit RFQ
MOE RuleFormer MOEAMCAMSCNIMSCIMCIMC ActivityAACDSORCollaboratorsReceiversEffective Date
ZC011 Apr 1991
Code Definitions

FLIS - SEG C - REFERENCE NUMBER | NSN 5930-01-258-5802 Submit RFQ
RNFCRNCCRNVCDACRNAACRNSCRNJCSADCMSDSHCCReference NumberCAGE
3249ZDM1300272282  82647   CAGE/82647
Code Definitions

3

Reference Number Category Code (RNCC_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

2

Reference Number Variation Code (RNVC_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.

4

Document Availability Code (DAC_2640)


The reference number is represented by technical documentation other than a drawing and the documentation was available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number; however, the RNAAC cannot furnish the technical documentation.

9Z

Reference Number Action Activity Code (RNAAC_2900)


DLIS-K, Battle Creek, MI 49037-3084

D

Reference Number Status Code (RNSC_2923)


Procurement authority of the manufacturer and reference number have not yet been checked. NOTE: This code is to be allocated to reference numbers still requiring checks on procurement authority.


FLIS - SEG E - ITEM STANDARDIZATION DATA | NSN 5930-01-258-5802 Submit RFQ
ISCOriginatorNIIN StatusReplaced / Replacement ISCReplaced / Replacement OriginatorReplacement NIIN StatusReplacement DateReplaced / Replacement NSNDecision Date
59704 Jul 1987
Code Definitions

5

Item Standardization Code (ISC_2650)


An item authorized for procurement that has not yet been subject to item standardization.

97

Originator of Standardization Decision (ORG_STDZN_DEC_9325)


DLIS-LFF, Battle Creek, MI 49037-3084

0

NIIN Status Code (NIIN_STAT_CD_2670)


Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.

4 Jul 1987

Standardization Decision Date (DT_STDZN_DEC_2300)


FLIS - SEG G - FREIGHT DATA | NSN 5930-01-258-5802 Submit RFQ
IntegrityOriginatingHMCLCLWCCTCCSHCADCACCASHLTLNMFCNMFC Sub ItemUFCFreight DescriptionRail Variance
ZC
Code Definitions

ZC

Originating Activity Code (ORIG_ACTY_CD_4210)


Canada

Rail Variance

Rail Variance (RAIL_VARI_CD_4760)


No Variation. NMFC and UFCC Match.


FLIS - SEG M/V - CHARACTERISTICS DATA | NSN 5930-01-258-5802 Submit RFQ
MRCDecoded RequirementClear Text Reply
ABPMBody Diameter0.572 INCHES MAXIMUM
ADAUBody Height0.315 INCHES NOMINAL
CQGBContact Action StimulusINCREASE
CTYCContact AdjustabilityACTUATION POINT NOT ADJUSTABLE AND DEACTUATION POINT NOT ADJUSTABLE
CTHFContact Load Current Rating1.0 AMPERES RESISTIVE LOAD FOURTH VOLTAGE AND 1.5 AMPERES RESISTIVE LOAD FOURTH VOLTAGE AND 2.0 AMPERES RESISTIVE LOAD FOURTH VOLTAGE AND 2.5 AMPERES RESISTIVE LOAD FOURTH VOLTAGE AND 3.0 AMPERES RESISTIVE LOAD FOURTH VOLTAGE
CTHFContact Load Current Rating2.0 AMPERES RESISTIVE LOAD THIRD VOLTAGE AND 3.0 AMPERES RESISTIVE LOAD THIRD VOLTAGE AND 4.0 AMPERES RESISTIVE LOAD THIRD VOLTAGE AND 5.0 AMPERES RESISTIVE LOAD THIRD VOLTAGE AND 6.0 AMPERES RESISTIVE LOAD THIRD VOLTAGE
CTHFContact Load Current Rating5.0 AMPERES RESISTIVE LOAD FIRST VOLTAGE AND 5.5 AMPERES RESISTIVE LOAD FIRST VOLTAGE AND 6.0 AMPERES RESISTIVE LOAD FIRST VOLTAGE AND 6.5 AMPERES RESISTIVE LOAD FIRST VOLTAGE AND 7.0 AMPERES RESISTIVE LOAD FIRST VOLTAGE
CTHFContact Load Current Rating5.0 AMPERES RESISTIVE LOAD SECOND VOLTAGE AND 5.5 AMPERES RESISTIVE LOAD SECOND VOLTAGE AND 6.0 AMPERES RESISTIVE LOAD SECOND VOLTAGE AND 6.5 AMPERES RESISTIVE LOAD SECOND VOLTAGE AND 7.0 AMPERES RESISTIVE LOAD SECOND VOLTAGE
CTYXContact Stimulus Rating300.00 ACTUATION POINT NOMINAL DEGREES FAHRENHEIT AND 270.00 DEACTUATION POINT NOMINAL DEGREES FAHRENHEIT
CTZBContact Voltage Rating In Volts125.0 AC AT SEA LEVEL THIRD VOLTAGE
CTZBContact Voltage Rating In Volts250.0 AC AT SEA LEVEL FOURTH VOLTAGE
CTZBContact Voltage Rating In Volts30.0 DC AT SEA LEVEL FIRST VOLTAGE
CTZBContact Voltage Rating In Volts30.0 AC AT SEA LEVEL SECOND VOLTAGE
AEJNDistance Between Mounting Facility Centers0.937 INCHES NOMINAL
CBBLFeatures ProvidedHERMETICALLY SEALED CASE
MEDAMedia For Which DesignedGAS OR LIQUID
CQYJMounting Facility PatternTWO POSITION IN-LINE
AXGYMounting MethodBRACKET
CRLDNonpile-Up Contact Arrangement1 POLE, SINGLE THROW, NORMALLY OPEN, MOMENTARY ACTION
ABHPOverall Length1.160 INCHES MINIMUM AND 1.260 INCHES MAXIMUM
STYLStyle DesignatorDISC W/FLANGE
PMLCPrecious Material And LocationCONTACTS SILVER
PRMTPrecious MaterialSILVER
ABKWOverall Height0.500 INCHES MAXIMUM
AKBYTemp Sensing Element TypeDISC
CSCFTerminal TypeTAB, SOLDER LUG


Back to Top