5930-01-290-8277

SWITCH,ROTARY


5930-01-290-8277 (5930012908277, 012908277)
Part Number (1 listing): IC5844K4SXXXX94BC
Summary

FSG 59 / FSC 5930

DEMIL: A

DEMIL INT:

HMIC: P

Date Created: 17 Dec 1988

MSDS: None

Hazmat: None

Request a Quote


;



MASTER CROSS REFERENCE LIST (MCRL) | NSN 5930-01-290-8277 Submit RFQ
Manufacturer Part NumberRNCCRNVCManufacturer NameCAGE
IC5844K4SXXXX94BC3 - Design Control Reference2 - Production ItemGENERAL ELECTRIC CO  02989    CAGE 02989  
Code Definitions

3 - Design Control Reference

Reference Number Category Code (DRN_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

2 - Production Item

Reference Number Variation Code (DRN_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.


FLIS - SEG A - IDENTIFICATION | NSN 5930-01-290-8277 Submit RFQ
FSGFSCNIINFIIGINCCRITICALITYTYPE OF ITEMMRCDEMILHMICEDCPMICADPECDATE CREATED
595930012908277A052B002134X43APU17 Dec 1988
Code Definitions

59

Federal Supply Group (FSG_3994/FSC_WI_FSG_3996)


Electrical and Electronic Equipment Components

5930

Federal Supply Class (FSC_3994/FSC_WI_FSC_3996)


Switches

012908277

National Item Identification Number (NCB_CD_4130/I_I_NBR_4131)


NSN 5930-01-290-8277

A052B0

Federal Item Identification Guide (FIIG_4065)

02134

Item Naming Code (INC_4080)

17 Dec 1988

NIIN Assignment Date (DT_NIIN_ASGMT_2180)

X

Item Criticality (CRITL_CD_FIIG_3843)


The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.

4

Type of Item Identification (TYP_II_4820)


Partial Descriptive Item Identification (Type 1 Concept)

3

Reference / Partial Descriptive Method Reason Code (RPDMRC_4765)


An approved item name and FIIG exist but the item involved is so unique in design that it cannot be fully described in accordance with the FIIG.

A

Demilitarization Code (DEMIL_CD_0167)


Non-MLI/ Non-SLI — Demilitarization not required.

P

Hazardous Material Indicator Code (HMIC_0865)


Indicates there is no information in the HMIRS; however, the NSN is in a FSC in Table II of Federal Standard 313 and a MSDS may be required by the user. The requirement for a MSDS is dependent on a hazard determination of the supplier or the intended end use of the product.

U

Precious Metals Indicator Code (PMIC_0802)


Precious Metal Content is unknown.


FLIS - SEG B - MOE RULE DATA | NSN 5930-01-290-8277 Submit RFQ
MOE RuleFormer MOEAMCAMSCNIMSCIMCIMC ActivityAACDSORCollaboratorsReceiversEffective Date
ZC011 Apr 1991
Code Definitions

FLIS - SEG C - REFERENCE NUMBER | NSN 5930-01-290-8277 Submit RFQ
RNFCRNCCRNVCDACRNAACRNSCRNJCSADCMSDSHCCReference NumberCAGE
3269ZDIC5844K4SXXXX94BC  02989   CAGE/02989
Code Definitions

3

Reference Number Category Code (RNCC_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

2

Reference Number Variation Code (RNVC_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.

6

Document Availability Code (DAC_2640)


The reference number is represented by technical documentation other than a drawing but the documentation was not available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number.

9Z

Reference Number Action Activity Code (RNAAC_2900)


DLIS-K, Battle Creek, MI 49037-3084

D

Reference Number Status Code (RNSC_2923)


Procurement authority of the manufacturer and reference number have not yet been checked. NOTE: This code is to be allocated to reference numbers still requiring checks on procurement authority.


FLIS - SEG E - ITEM STANDARDIZATION DATA | NSN 5930-01-290-8277 Submit RFQ
ISCOriginatorNIIN StatusReplaced / Replacement ISCReplaced / Replacement OriginatorReplacement NIIN StatusReplacement DateReplaced / Replacement NSNDecision Date
6TX021 Dec 1988
Code Definitions

6

Item Standardization Code (ISC_2650)


An item authorized for procurement that is in a specific Federal Supply Class (FSC) or item name grouping consisting primarily of items which are one-of-a-kind; therefore, little or no potential exists for elimination of items through formal item reduction studies.

TX

Originator of Standardization Decision (ORG_STDZN_DEC_9325)


Defense Supply Center Columbus, Columbus, OH 43218

0

NIIN Status Code (NIIN_STAT_CD_2670)


Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.

21 Dec 1988

Standardization Decision Date (DT_STDZN_DEC_2300)


FLIS - SEG G - FREIGHT DATA | NSN 5930-01-290-8277 Submit RFQ
IntegrityOriginatingHMCLCLWCCTCCSHCADCACCASHLTLNMFCNMFC Sub ItemUFCFreight DescriptionRail Variance
ZC
Code Definitions

ZC

Originating Activity Code (ORIG_ACTY_CD_4210)


Canada

Rail Variance

Rail Variance (RAIL_VARI_CD_4760)


No Variation. NMFC and UFCC Match.


FLIS - SEG M/V - CHARACTERISTICS DATA | NSN 5930-01-290-8277 Submit RFQ
MRCDecoded RequirementClear Text Reply
CTHFContact Load Current Rating10.0 AMPERES INDUCTIVE LOAD LOWEST AC VOLTAGE RATING AT SEA LEVEL
CTHFContact Load Current Rating10.0 AMPERES INDUCTIVE LOAD LOWEST DC VOLTAGE RATING AT SEA LEVEL
CTHFContact Load Current Rating2.0 AMPERES INDUCTIVE LOAD HIGHEST DC VOLTAGE RATING AT SEA LEVEL
CTHFContact Load Current Rating3.0 AMPERES INDUCTIVE LOAD HIGHEST AC VOLTAGE RATING AT SEA LEVEL
CQMKContact Voltage Rating In Volts120.0 LOWEST AC VOLTAGE RATING AT SEA LEVEL
CQMKContact Voltage Rating In Volts250.0 HIGHEST DC VOLTAGE RATING AT SEA LEVEL
CQMKContact Voltage Rating In Volts28.0 LOWEST DC VOLTAGE RATING AT SEA LEVEL
CQMKContact Voltage Rating In Volts480.0 HIGHEST AC VOLTAGE RATING AT SEA LEVEL
CBBLFeatures ProvidedACTUATOR KNOB AND LEGEND PLATE
CQYJMounting Facility PatternFOUR POSITION RECTANGULAR SINGLE MOUNTING FACILITY
AXGYMounting MethodFLANGE SINGLE MOUNTING FACILITY AND UNTHREADED HOLE SINGLE MOUNTING FACILITY
AFDVLongest Vertical Distance Between Mounting Centers5.700 INCHES NOMINAL SINGLE MOUNTING FACILITY
AFDSLongest Horizontal Distance Between Mounting Centers2.000 INCHES NOMINAL SINGLE MOUNTING FACILITY
ABKWOverall Height4.450 INCHES NOMINAL
ABHPOverall Length6.300 INCHES NOMINAL
ABMKOverall Width3.700 INCHES NOMINAL
FEATSpecial FeaturesLEGEND PLATE READS: EMER STOP; SUBMERSIBLE
AEBVUnthreaded Mounting Hole Diameter0.230 INCHES NOMINAL SINGLE MOUNTING FACILITY
CRJHSwitch Actuator Indexing Position Quantity2 SINGLE ACTUATOR
CSLCSwitch Actuator Positioning Increment90.0 DEGREES SINGLE ACTUATOR