5930-01-313-4098

SWITCH,PRESSURE


5930-01-313-4098 (5930013134098, 013134098)
Part Numbers (2 listings): 40048241 | 8342487 |
Summary

FSG 59 / FSC 5930

DEMIL: A

DEMIL INT:

HMIC: P

Date Created: 8 Jan 1990

MSDS: None

Hazmat: None

Request a Quote


;



MASTER CROSS REFERENCE LIST (MCRL) | NSN 5930-01-313-4098 Submit RFQ
Manufacturer Part NumberRNCCRNVCManufacturer NameCAGE
400482413 - Design Control Reference9 - No Longer UsedGENERAL MOTORS CORP  72915    CAGE 72915  
83424875 - Replaced / Discontinued9 - No Longer UsedGENERAL MOTORS CORP  72915    CAGE 72915  
Code Definitions

3 - Design Control Reference

Reference Number Category Code (DRN_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

5 - Replaced / Discontinued

Reference Number Category Code (DRN_2910)


Secondary Reference. Any additional number, other than a primary number (codes 1,2,3,4) informative reference (code 6) or vendor item drawing reference (code 7) assigned to an item of production or supply by a commercial or Government organization, which represents the same item of production or supply to which the National Stock Number (NSN) was assigned. The reference number may have had an RNCC of 1, 2, 3, 4 or 7 but has since been replaced in the item-of-supply concept of the NSN by another primary number.

9 - No Longer Used

Reference Number Variation Code (DRN_4780)


A specification, standard, or other reference number which is superseded, canceled, obsolete or discontinued and is coded Reference Number Category Code (RNCC) 5; a reference number for information only coded RNCC 6; or a reference number coded RNCC D.


FLIS - SEG A - IDENTIFICATION | NSN 5930-01-313-4098 Submit RFQ
FSGFSCNIINFIIGINCCRITICALITYTYPE OF ITEMMRCDEMILHMICEDCPMICADPECDATE CREATED
595930013134098A048B000206XKAPA8 Jan 1990
Code Definitions

59

Federal Supply Group (FSG_3994/FSC_WI_FSG_3996)


Electrical and Electronic Equipment Components

5930

Federal Supply Class (FSC_3994/FSC_WI_FSC_3996)


Switches

013134098

National Item Identification Number (NCB_CD_4130/I_I_NBR_4131)


NSN 5930-01-313-4098

A048B0

Federal Item Identification Guide (FIIG_4065)

00206

Item Naming Code (INC_4080)

8 Jan 1990

NIIN Assignment Date (DT_NIIN_ASGMT_2180)

X

Item Criticality (CRITL_CD_FIIG_3843)


The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.

K

Type of Item Identification (TYP_II_4820)


Full Descriptive - Reference Item Identification

A

Demilitarization Code (DEMIL_CD_0167)


Non-MLI/ Non-SLI — Demilitarization not required.

P

Hazardous Material Indicator Code (HMIC_0865)


Indicates there is no information in the HMIRS; however, the NSN is in a FSC in Table II of Federal Standard 313 and a MSDS may be required by the user. The requirement for a MSDS is dependent on a hazard determination of the supplier or the intended end use of the product.

A

Precious Metals Indicator Code (PMIC_0802)


Item does not contain Precious Metal.


FLIS - SEG B - MOE RULE DATA | NSN 5930-01-313-4098 Submit RFQ
MOE RuleFormer MOEAMCAMSCNIMSCIMCIMC ActivityAACDSORCollaboratorsReceiversEffective Date
YA011 Dec 2001
Code Definitions

FLIS - SEG C - REFERENCE NUMBER | NSN 5930-01-313-4098 Submit RFQ
RNFCRNCCRNVCDACRNAACRNSCRNJCSADCMSDSHCCReference NumberCAGE
393ZZ40048241  72915   CAGE/72915
Code Definitions

3

Reference Number Category Code (RNCC_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

9

Reference Number Variation Code (RNVC_4780)


A specification, standard, or other reference number which is superseded, canceled, obsolete or discontinued and is coded Reference Number Category Code (RNCC) 5; a reference number for information only coded RNCC 6; or a reference number coded RNCC D.

3

Document Availability Code (DAC_2640)


The reference number is represented by technical documentation other than a drawing and the documentation was available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number. The RNAAC will furnish the technical documentation upon request.

ZZ

Reference Number Action Activity Code (RNAAC_2900)


USA


FLIS - SEG E - ITEM STANDARDIZATION DATA | NSN 5930-01-313-4098 Submit RFQ
ISCOriginatorNIIN StatusReplaced / Replacement ISCReplaced / Replacement OriginatorReplacement NIIN StatusReplacement DateReplaced / Replacement NSNDecision Date
59708 Jan 1990
Code Definitions

5

Item Standardization Code (ISC_2650)


An item authorized for procurement that has not yet been subject to item standardization.

97

Originator of Standardization Decision (ORG_STDZN_DEC_9325)


DLIS-LFF, Battle Creek, MI 49037-3084

0

NIIN Status Code (NIIN_STAT_CD_2670)


Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.

8 Jan 1990

Standardization Decision Date (DT_STDZN_DEC_2300)


FLIS - SEG G - FREIGHT DATA | NSN 5930-01-313-4098 Submit RFQ
IntegrityOriginatingHMCLCLWCCTCCSHCADCACCASHLTLNMFCNMFC Sub ItemUFCFreight DescriptionRail Variance
658Z9AHZP061300X34410CIRCUIT-BREAKER-SWITCH-NOI
Code Definitions

XF

Originating Activity Code (ORIG_ACTY_CD_4210)


658

Water Commodity Code (WRT_CMDTY_CD_9275)


Electical Appliances, Small

Z

Type Cargo Code (TYPE_CGO_CD_9260)


No special type of cargo code applicable

9

Special Handling Code (SP_HDLG_CD_9240)


No special handling required

A

Air Dimension Code (AIR_DIM_CD_9220)


Shipment is not a consolidation and does not exceed 72 inches in any dimension.

H

Air Commodity Code (AIR_CMTY_HDLG_9215)


Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.

Z

Air Special Handling Code (AIR_CMTY_HDLG_9215)


No special handling required.

P

Less Than Truckload (CLAS_RTNG_CD_2770)


77.5

061300

National Motor Freight Classification Number (NMFC Item Number) (NMFC_2850)

X

NMFC Sub Item Number (SUB_ITM_NBR_0861)

34410

Uniform Freight Classification (UFC_CD_MODF_3040)

CIRCUIT-BREAKER-SWITCH-NOI

Freight Description (FRT_DESC_4020)

Rail Variance

Rail Variance (RAIL_VARI_CD_4760)


No Variation. NMFC and UFCC Match.


FLIS - SEG M/V - CHARACTERISTICS DATA | NSN 5930-01-313-4098 Submit RFQ
MRCDecoded RequirementClear Text Reply
ADAUBody Height3.310 INCHES NOMINAL
CQGBContact Action StimulusDECREASE
CTYCContact AdjustabilityACTUATION POINT ADJUSTABLE, PRESET
CTYMContact Adjustment Range+1.00/+75.00 ACTUATION POINT POUNDS PER SQUARE INCH
CTYSContact Adjustment TypeEXTERNAL ACTUATION POINT SCREW
CTHFContact Load Current Rating0.6 AMPERES RESISTIVE LOAD FIRST VOLTAGE
CTHFContact Load Current Rating0.7 AMPERES RESISTIVE LOAD SECOND VOLTAGE
CTHFContact Load Current Rating1.5 AMPERES RESISTIVE LOAD THIRD VOLTAGE
CTHFContact Load Current Rating3.0 AMPERES RESISTIVE LOAD FOURTH VOLTAGE
CTYXContact Stimulus Rating10.00 ACTUATION POINT NOMINAL POUNDS PER SQUARE INCH
CTZBContact Voltage Rating In Volts120.0 AC AT SEA LEVEL FOURTH VOLTAGE
CTZBContact Voltage Rating In Volts240.0 AC AT SEA LEVEL THIRD VOLTAGE
CTZBContact Voltage Rating In Volts480.0 AC AT SEA LEVEL SECOND VOLTAGE
CTZBContact Voltage Rating In Volts600.0 AC AT SEA LEVEL FIRST VOLTAGE
AGAVEnd Item IdentificationUSED ON MAIN PROPULSION SYSTEM ONBOARD 180 FT WLB AND VARIOUS OTHER COAST GUARD VESSELS
CBBLFeatures ProvidedELECTRICAL ACCESS PORT
MEDAMedia For Which DesignedGAS OR LIQUID
CQYJMounting Facility PatternTWO POSITION DIAGONAL
AXGYMounting MethodUNTHREADED HOLE
CQJXNominal Thread Size0.250 INCHES SINGLE PRESSURE CONNECTION
CRLDNonpile-Up Contact Arrangement1 TWO CIRCUIT, DOUBLE BREAK/DOUBLE MAKE, ONE POSITION MOMENTARY
AWTNOperating Temp Rating185.0 DEG FAHRENHEIT MAXIMUM
STYLStyle DesignatorRECTANGULAR
AARXInside Diameter0.500 INCHES NOMINAL SINGLE CONNECTION
AFDVLongest Vertical Distance Between Mounting Centers2.720 INCHES NOMINAL
AFDSLongest Horizontal Distance Between Mounting Centers2.720 INCHES NOMINAL
AJZCPressure Switch TypeGAGE
CTZLPressure Connector TypePLAIN, THREADED INTERNAL SINGLE CONNECTION
CQJBProof Pressure100.00 POUNDS PER SQUARE INCH
ABKWOverall Height6.500 INCHES NOMINAL
ABHPOverall Length3.600 INCHES NOMINAL
ABMKOverall Width2.660 INCHES NOMINAL
THSDThread Series DesignatorNPT SINGLE PRESSURE CONNECTION
AEBVUnthreaded Mounting Hole Diameter0.280 INCHES NOMINAL
CSCFTerminal TypeTAB W/SCREW


Back to Top