5930-01-314-0970

SWITCH,CODE INDICATING WHEEL


5930-01-314-0970 (5930013140970, 013140970)
Part Number (1 listing): T20-89A4
Summary

FSG 59 / FSC 5930

DEMIL: A

DEMIL INT:

HMIC: P

Date Created: 23 Jan 1990

Request a Quote


;



MASTER CROSS REFERENCE LIST (MCRL) | NSN 5930-01-314-0970 Submit RFQ
Manufacturer Part NumberRNCCRNVCManufacturer NameCAGE
T20-89A43 - Design Control Reference9 - No Longer UsedCHERRY ELECTRICAL PRODUCTS CORP  01963      
Code Definitions

3 - Design Control Reference

Reference Number Category Code (DRN_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

9 - No Longer Used

Reference Number Variation Code (DRN_4780)


A specification, standard, or other reference number which is superseded, canceled, obsolete or discontinued and is coded Reference Number Category Code (RNCC) 5; a reference number for information only coded RNCC 6; or a reference number coded RNCC D.


FLIS - SEG A - IDENTIFICATION | NSN 5930-01-314-0970 Submit RFQ
FSGFSCNIINFIIGINCCRITICALITYTYPE OF ITEMMRCDEMILHMICEDCPMICADPECDATE CREATED
595930013140970A052B062415X43APG023 Jan 1990
Code Definitions

59

Federal Supply Group (FSG_3994/FSC_WI_FSG_3996)


Electrical and Electronic Equipment Components

5930

Federal Supply Class (FSC_3994/FSC_WI_FSC_3996)


Switches

013140970

National Item Identification Number (NCB_CD_4130/I_I_NBR_4131)


NSN 5930-01-314-0970

A052B0

Federal Item Identification Guide (FIIG_4065)

62415

Item Naming Code (INC_4080)

23 Jan 1990

NIIN Assignment Date (DT_NIIN_ASGMT_2180)

X

Item Criticality (CRITL_CD_FIIG_3843)


The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.

4

Type of Item Identification (TYP_II_4820)


Partial Descriptive Item Identification (Type 1 Concept)

3

Reference / Partial Descriptive Method Reason Code (RPDMRC_4765)


An approved item name and FIIG exist but the item involved is so unique in design that it cannot be fully described in accordance with the FIIG.

A

Demilitarization Code (DEMIL_CD_0167)


Non-MLI/ Non-SLI — Demilitarization not required.

P

Hazardous Material Indicator Code (HMIC_0865)


Indicates there is no information in the HMIRS; however, the NSN is in a FSC in Table II of Federal Standard 313 and a MSDS may be required by the user. The requirement for a MSDS is dependent on a hazard determination of the supplier or the intended end use of the product.

G

Precious Metals Indicator Code (PMIC_0802)


Item contains gold.

0

ADPE Identification Code (ADPEC_0801)


Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9)


FLIS - SEG B - MOE RULE DATA | NSN 5930-01-314-0970 Submit RFQ
MOE RuleFormer MOEAMCAMSCNIMSCIMCIMC ActivityAACDSORCollaboratorsReceiversEffective Date
YS011 Feb 2015
Code Definitions

FLIS - SEG E - ITEM STANDARDIZATION DATA | NSN 5930-01-314-0970 Submit RFQ
ISCOriginatorNIIN StatusReplaced / Replacement ISCReplaced / Replacement OriginatorReplacement NIIN StatusReplacement DateReplaced / Replacement NSNDecision Date
6TX627 Jan 1990
Code Definitions

6

Item Standardization Code (ISC_2650)


An item authorized for procurement that is in a specific Federal Supply Class (FSC) or item name grouping consisting primarily of items which are one-of-a-kind; therefore, little or no potential exists for elimination of items through formal item reduction studies.

TX

Originator of Standardization Decision (ORG_STDZN_DEC_9325)


Defense Supply Center Columbus, Columbus, OH 43218

6

NIIN Status Code (NIIN_STAT_CD_2670)


Item is inactive (no recorded Primary/Secondary Inventory Control Activity (PICA/SICA)). File data coded KFD is forwarded.

27 Jan 1990

Standardization Decision Date (DT_STDZN_DEC_2300)


FLIS - SEG G - FREIGHT DATA | NSN 5930-01-314-0970 Submit RFQ
IntegrityOriginatingHMCLCLWCCTCCSHCADCACCASHLTLNMFCNMFC Sub ItemUFCFreight DescriptionRail Variance
TA
Code Definitions

TA

Originating Activity Code (ORIG_ACTY_CD_4210)


Sacramento Air Logistics Center, McClellan AFB, CA 95652-5609

Rail Variance

Rail Variance (RAIL_VARI_CD_4760)


No Variation. NMFC and UFCC Match.


FLIS - SEG M/V - CHARACTERISTICS DATA | NSN 5930-01-314-0970 Submit RFQ
MRCDecoded RequirementClear Text Reply
STYLStyle DesignatorRECTANGULAR INLINE INDICATING
ABHPOverall Length2.765 INCHES NOMINAL
ABKWOverall Height2.415 INCHES NOMINAL
ABMKOverall Width1.150 INCHES NOMINAL
AFBHIndividual Section Quantity4
CTZFReadout Indicator Marking0,1,2,3,4,5,6,7,8,9,A,B,C,D,E,F EACH SECTION
HUESColorBLACK EACH BODY
HUESColorBLACK EACH INDICATOR BACKGROUND
HUESColorWHITE EACH INDICATOR MARKING
CTZTContact Arrangement Truth TableSPECIAL EACH SECTION
AYDWActuator TypeTHUMBWHEEL ALL ACTUATORS
CRJHSwitch Actuator Indexing Position Quantity16 ALL ACTUATORS
CSCFTerminal TypePRINTED CIRCUIT
AXGYMounting MethodUNTHREADED HOLE SINGLE MOUNTING FACILITY
AEBVUnthreaded Mounting Hole Diameter0.100 INCHES NOMINAL SINGLE MOUNTING FACILITY
CQYJMounting Facility PatternFOUR POSITION RECTANGULAR SINGLE MOUNTING FACILITY
AFDSLongest Horizontal Distance Between Mounting Centers2.595 INCHES NOMINAL SINGLE MOUNTING FACILITY
AFDVLongest Vertical Distance Between Mounting Centers0.900 INCHES NOMINAL SINGLE MOUNTING FACILITY
ABFEHazardous Locations/Environmental ProtectionDUSTPROOF
PRMTPrecious MaterialGOLD
PMLCPrecious Material And LocationCONTACTS GOLD


Back to Top