Manufacturer Part Number | RNCC | RNVC | Manufacturer Name | CAGE | |
---|---|---|---|---|---|
283-0011-030 | 3 - Design Control Reference | 2 - Production Item | ROCKWELL COLLINS, INC. | 13499 | ![]() |
71MY233334 | 5 - Replaced / Discontinued | 2 - Production Item | GRAYHILL, INC | 81073 | ![]() |
Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.
Secondary Reference. Any additional number, other than a primary number (codes 1,2,3,4) informative reference (code 6) or vendor item drawing reference (code 7) assigned to an item of production or supply by a commercial or Government organization, which represents the same item of production or supply to which the National Stock Number (NSN) was assigned. The reference number may have had an RNCC of 1, 2, 3, 4 or 7 but has since been replaced in the item-of-supply concept of the NSN by another primary number.
A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.
FSG | FSC | NIIN | FIIG | INC | CRITICALITY | TYPE OF ITEM | MRC | DEMIL | HMIC | EDC | PMIC | ADPEC | DATE CREATED |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
59 | 5930 | 013484280 | A052B0 | 02134 | X | 1 | A | P | C | 9 Nov 1991 |
The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Full Descriptive Item Identification
Non-MLI/ Non-SLI — Demilitarization not required.
Indicates there is no information in the HMIRS; however, the NSN is in a FSC in Table II of Federal Standard 313 and a MSDS may be required by the user. The requirement for a MSDS is dependent on a hazard determination of the supplier or the intended end use of the product.
Item contains combination of two or more precious metals (silver, gold, platinum).
MOE Rule | Former MOE | AMC | AMSC | NIMSC | IMC | IMC Activity | AAC | DSOR | Collaborators | Receivers | Effective Date | |||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
FXGX | FXTX | 3 | C | Z | SX | 1 Nov 2005 | ||||||||||||||||||||||||
WP01 | 1 Jun 2011 |
Acquire directly from the actual manufacturer, whether or not the prime contractor is the actual manufacturer.
This part requires engineering source approval by the design control activity in order to maintain the quality of the part. An alternate source must qualify in accordance with the design control activity's procedures, as approved by the cognizant Government engineering activity. Valid AMCs: 1, 2, 3, 4 and 5.
Integrated Management: Relinquishment of Service management of an item in designated commodity oriented Federal Supply Classes to the IMM (FSC manager) for management.
Oklahoma City Air Logistics Center, Tinker AFB, OK 73145-3043
RNFC | RNCC | RNVC | DAC | RNAAC | RNSC | RNJC | SADC | MSDS | HCC | Reference Number | CAGE | |
---|---|---|---|---|---|---|---|---|---|---|---|---|
3 | 2 | A | TX | 283-0011-030 | 13499 | ![]() | ||||||
5 | 2 | 5 | TX | 71MY233334 | 81073 | ![]() |
Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.
A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.
The reference number is represented by an engineering drawing and the drawing is available for unlimited use. The drawing will be furnished by the activity identified by the RNAAC upon request.
Defense Supply Center Columbus, Columbus, OH 43218
Secondary Reference. Any additional number, other than a primary number (codes 1,2,3,4) informative reference (code 6) or vendor item drawing reference (code 7) assigned to an item of production or supply by a commercial or Government organization, which represents the same item of production or supply to which the National Stock Number (NSN) was assigned. The reference number may have had an RNCC of 1, 2, 3, 4 or 7 but has since been replaced in the item-of-supply concept of the NSN by another primary number.
The reference number is represented by a drawing, but the drawing was not available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number.
ISC | Originator | NIIN Status | Replaced / Replacement ISC | Replaced / Replacement Originator | Replacement NIIN Status | Replacement Date | Replaced / Replacement NSN | Decision Date |
---|---|---|---|---|---|---|---|---|
5 | 97 | 0 | 9 Nov 1991 |
An item authorized for procurement that has not yet been subject to item standardization.
DLIS-LFF, Battle Creek, MI 49037-3084
Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.
Integrity | Originating | HMC | LCL | WCC | TCC | SHC | ADC | ACC | ASH | LTL | NMFC | NMFC Sub Item | UFC | Freight Description | Rail Variance |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
TH | 72D | Z | 9 | A | H | Z | P | 061300 | X | 34410 | CIRCUIT-BREAKER-SWITCH-NOI |
Defense Supply Center Columbus, Columbus, OH 43215
Communications/Electronics, other than SIGINT/EW or COMSEC. Repair Parts and Components
No special type of cargo code applicable
No special handling required
Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
No special handling required.
77.5
No Variation. NMFC and UFCC Match.
Defense Logistics Agency, Enterprise Business Systems
INSURANCE/NUMERIC STOCKAGE OBJECTIVE ITEM. Items which may be required occasionally or intermittently, and prudence requires that a nominal quantity of materiel be stocked due to the essentiality or the lead time of the item. 1. The item is centrally managed, stocked, and issued. 2. Requisitions will be submitted in accordance with IMM/Service requisitioning procedures.
Unclassified
1
AIR FORCE ERRC XB3: Stock Fund (Except Munitions); DLA: This item has been reviewed and a determination made that the item cannot or should not be restored to a serviceable condition from an unserviceable condition; NAVY: 1I cog not stocked print on demand flat forms
Each - A numeric quantity of one item of supply. Do not use if a more specific term applies, such as kit, set, assortment, assembly, group, sheet, plate, strip or length.
TYPE I or TYPE II (Non-Deteriorative/No Shelf-Life) - An individual item of supply which is determined through an evaluation of technical test data and/or actual experience to be an item with a definite non-extendible period of shelf-life OR An individual item of supply having an assigned shelf-life time period that may be extended after completion of inspection/test/restorative action.
Department of the Air Force
Defense Logistics Agency
Source | PICA / SICA | Packaging Category | Storage | Preservation | Clean/Dry | INT Qty | Unit Weight | Unit Size | Unit Pack Cube | Item Weight | Item Dims |
---|---|---|---|---|---|---|---|---|---|---|---|
P | P | ZZ | XXX | 0.1 lbs | 0.003 cu ft |
Preservation Material | Wrapping Material | Cushioning / Dunnage | Cushioning Thickness | Unit Container | Intermediate Container | Unit Container Level | Special Marking | Level A Packing | Level B Packing | Minimal Packing | Optional Procedure |
---|---|---|---|---|---|---|---|---|---|---|---|
X | 00 | Q | Q | O |
Primary Inventory Control Activity (PICA)
Primary Inventory Control Activity (PICA)
See J.4.1.b
As required to protect the item or elements of the package
No special marking
Packing shall be accomplished in accordance with table C.II for the packing level specified. Closure sealing and reinforcement shall be in accordance with applicable specification for shipping container.
Packing shall be accomplished in accordance with table C-II for the packing level specified. Closure sealing and reinforcement shall be in accordance with the appropriate shipping container specification.
Options can be exercised as to specific method of preservation or DoD approved packaging materials to be used. However, basic preservation method shall be retained, supplemental data shall be complied with, and unit package dimensions shall not be increased by more than one inch. Equal or better protection shall be given the item and there shall be no increase in the package cost.
MRC | Decoded Requirement | Clear Text Reply |
---|---|---|
CTHF | Contact Load Current Rating | 150.0 MILLIAMPERES RESISTIVE LOAD AC AT SEA LEVEL30.0 MILLIAMPERES INDUCTIVE LOAD DC AT SEA LEVEL AND 200.0 MILLIAMPERES RESISTIVE LOAD DC AT SEA LEVEL |
CQMK | Contact Voltage Rating In Volts | 115.0 AC AT SEA LEVEL28.0 DC AT SEA LEVEL |
CSMW | Detent Rotational Torque Range | +0.250/+2.000 INCH-POUNDS SINGLE ACTUATOR |
ABNB | First Flat Length | 0.230 INCHES MINIMUM ALL ACTUATORS AND 0.270 INCHES MAXIMUM ALL ACTUATORS |
ABNC | Flat Height | 0.219 INCHES NOMINAL 1ST ACTUATOR0.086 INCHES NOMINAL 2ND ACTUATOR |
AXGY | Mounting Method | THREADED BUSHING SINGLE MOUNTING FACILITY |
CQJX | Nominal Thread Size | 0.375 INCHES SINGLE MOUNTING FACILITY |
AFDC | Nonturn Device Type | SLOTTED BUSHING AT 3:00 O'CLOCK |
AFGA | Operating Temp Range | -65.0/+85.0 DEG CELSIUS |
AFBH | Individual Section Quantity | 1 |
PMLC | Precious Material And Location | TERMINAL SURFACES AND CONTACTS SILVER AND CONTACT AND TERMINAL SURFACES GOLD |
PRMT | Precious Material | GOLD AND SILVER |
ABWV | Shaft Diameter | 0.248 INCHES MINIMUM 1ST ACTUATOR AND 0.251 INCHES MAXIMUM 1ST ACTUATOR0.123 INCHES MINIMUM 2ND ACTUATOR AND 0.126 INCHES MAXIMUM 2ND ACTUATOR |
ABXF | Shaft Length | 0.355 INCHES MINIMUM 1ST ACTUATOR AND 0.395 INCHES MAXIMUM 1ST ACTUATOR0.750 INCHES NOMINAL 2ND ACTUATOR |
CRSJ | Shaft Type | ROUND, FLATTED W/THROUGH HOLE 1ST ACTUATORROUND, FLATTED 2ND ACTUATOR |
ADAV | Overall Diameter | 0.676 INCHES MINIMUM AND 0.702 INCHES MAXIMUM |
ABHP | Overall Length | 2.165 INCHES NOMINAL |
THSD | Thread Series Designator | UNEF SINGLE MOUNTING FACILITY |
STYL | Style Designator | TAP, CIRCULAR, BUSHING MOUNT |
CRJH | Switch Actuator Indexing Position Quantity | 3 ALL ACTUATORS |
CQQT | Switch Actuator Momentary Position | CLOCKWISE ALL ACTUATORS AND COUNTERCLOCKWISE ALL ACTUATORS |
CSLC | Switch Actuator Positioning Increment | 36.0 DEGREES ALL ACTUATORS |
CTDN | Switch Actuator Stop Device Type | ADJUSTABLE STOP ALL ACTUATORS |
AJZE | Switch Contact Basic Design | NONPILE-UP NONSYMMETRICAL |
CSCF | Terminal Type | PRINTED CIRCUIT |
AAJD | Thread Class | 2A SINGLE MOUNTING FACILITY |
AASA | Thread Length | 0.292 INCHES MINIMUM SINGLE MOUNTING FACILITY AND 0.332 INCHES MAXIMUM SINGLE MOUNTING FACILITY |