Manufacturer Part Number | RNCC | RNVC | Manufacturer Name | CAGE | |
---|---|---|---|---|---|
57M22-05-1-16S-C | 3 - Design Control Reference | 2 - Production Item | GRAYHILL, INC | 81073 | ![]() |
Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.
A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.
FSG | FSC | NIIN | FIIG | INC | CRITICALITY | TYPE OF ITEM | MRC | DEMIL | HMIC | EDC | PMIC | ADPEC | DATE CREATED |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
59 | 5930 | 013594850 | A052B0 | 02134 | X | 1 | A | P | C | 6 Jun 1992 |
The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Full Descriptive Item Identification
Non-MLI/ Non-SLI — Demilitarization not required.
Indicates there is no information in the HMIRS; however, the NSN is in a FSC in Table II of Federal Standard 313 and a MSDS may be required by the user. The requirement for a MSDS is dependent on a hazard determination of the supplier or the intended end use of the product.
Item contains combination of two or more precious metals (silver, gold, platinum).
MOE Rule | Former MOE | AMC | AMSC | NIMSC | IMC | IMC Activity | AAC | DSOR | Collaborators | Receivers | Effective Date | |||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
FXGX | FXTX | 3 | Z | Z | SX | 1 Nov 2005 |
Acquire directly from the actual manufacturer, whether or not the prime contractor is the actual manufacturer.
This part is a commercial/non-developmental/off-the-shelf-item. Valid AMCs: 1, 2, 3, 4 and 5.
Integrated Management: Relinquishment of Service management of an item in designated commodity oriented Federal Supply Classes to the IMM (FSC manager) for management.
Oklahoma City Air Logistics Center, Tinker AFB, OK 73145-3043
RNFC | RNCC | RNVC | DAC | RNAAC | RNSC | RNJC | SADC | MSDS | HCC | Reference Number | CAGE | |
---|---|---|---|---|---|---|---|---|---|---|---|---|
3 | 2 | E | TX | 57M22-05-1-16S-C | 81073 | ![]() |
Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.
A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.
The reference number is represented by engineering data other than an engineering drawing. The data is available for unlimited use and will be furnished by the activity identified by the RNAAC upon request.
Defense Supply Center Columbus, Columbus, OH 43218
ISC | Originator | NIIN Status | Replaced / Replacement ISC | Replaced / Replacement Originator | Replacement NIIN Status | Replacement Date | Replaced / Replacement NSN | Decision Date |
---|---|---|---|---|---|---|---|---|
5 | 97 | 0 | 6 Jun 1992 |
An item authorized for procurement that has not yet been subject to item standardization.
DLIS-LFF, Battle Creek, MI 49037-3084
Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.
Integrity | Originating | HMC | LCL | WCC | TCC | SHC | ADC | ACC | ASH | LTL | NMFC | NMFC Sub Item | UFC | Freight Description | Rail Variance |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
TX | 72D | Z | 9 | A | H | Z | P | 061300 | X | 34410 | CIRCUIT-BREAKER-SWITCH-NOI |
Defense Supply Center Columbus, Columbus, OH 43218
Communications/Electronics, other than SIGINT/EW or COMSEC. Repair Parts and Components
No special type of cargo code applicable
No special handling required
Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
No special handling required.
77.5
No Variation. NMFC and UFCC Match.
Defense Logistics Agency, Enterprise Business Systems
NOT STOCKED, CENTRALLY PROCURED # (NON-STOCKED ITEMS) IMM/Service centrally managed but not stocked item. Procurement will be initiated only after receipt of a requisition.
Unclassified
No QUP
AIR FORCE ERRC XB3: Stock Fund (Except Munitions); DLA: This item has been reviewed and a determination made that the item cannot or should not be restored to a serviceable condition from an unserviceable condition; NAVY: 1I cog not stocked print on demand flat forms
Each - A numeric quantity of one item of supply. Do not use if a more specific term applies, such as kit, set, assortment, assembly, group, sheet, plate, strip or length.
TYPE I or TYPE II (Non-Deteriorative/No Shelf-Life) - An individual item of supply which is determined through an evaluation of technical test data and/or actual experience to be an item with a definite non-extendible period of shelf-life OR An individual item of supply having an assigned shelf-life time period that may be extended after completion of inspection/test/restorative action.
Department of the Air Force
Defense Logistics Agency
MRC | Decoded Requirement | Clear Text Reply |
---|---|---|
CTHF | Contact Load Current Rating | 600.0 MILLIAMPERES RESISTIVE LOAD AC AT SEA LEVEL600.0 MILLIAMPERES RESISTIVE LOAD DC AT SEA LEVEL AND 250.0 MILLIAMPERES INDUCTIVE LOAD DC AT SEA LEVEL |
CSHW | Contact Switching Action | MAKES BEFORE BREAKS EACH SECTION REAR |
CQMK | Contact Voltage Rating In Volts | 115.0 AC AT SEA LEVEL30.0 DC AT SEA LEVEL |
ABNB | First Flat Length | 0.250 INCHES NOMINAL SINGLE ACTUATOR |
ABNC | Flat Height | 0.219 INCHES NOMINAL SINGLE ACTUATOR |
ABFE | Hazardous Locations/Environmental Protection | MOISTURE RESISTANT AND SHOCK RESISTANT AND VIBRATION RESISTANT AND SALT SPRAY RESISTANT AND EXPLOSION RESISTANT |
AXGY | Mounting Method | THREADED BUSHING SINGLE MOUNTING FACILITY |
CQJX | Nominal Thread Size | 0.375 INCHES SINGLE MOUNTING FACILITY |
AEFP | Nonturn Device Radius | 0.375 INCHES NOMINAL AT 4:30 O'CLOCK |
AFDC | Nonturn Device Type | TAB AT 4:30 O'CLOCK |
AFGA | Operating Temp Range | -65.0/+125.0 DEG CELSIUS |
AFBH | Individual Section Quantity | 5 |
AKPX | Pole Quantity | 1 EACH SECTION FRONT |
PMLC | Precious Material And Location | TERMINAL SURFACES AND CONTACTS SILVER AND CONTACTS AND TERMINAL SURFACES GOLD |
PRMT | Precious Material | GOLD AND SILVER |
ABWV | Shaft Diameter | 0.250 INCHES NOMINAL SINGLE ACTUATOR |
ABXF | Shaft Length | 0.437 INCHES NOMINAL SINGLE ACTUATOR |
CQRQ | Shaft Flat/Slot Angular Location | 15.0 DEGREES FROM NONTURN DEVICE SINGLE ACTUATOR |
CRSJ | Shaft Type | ROUND, FLATTED SINGLE ACTUATOR |
ADAV | Overall Diameter | 1.190 INCHES NOMINAL |
ABHP | Overall Length | 3.122 INCHES NOMINAL |
THSD | Thread Series Designator | UNEF SINGLE MOUNTING FACILITY |
AKPY | Throw Quantity | 16 EACH SECTION REAR |
STYL | Style Designator | TAP, CIRCULAR, BUSHING MOUNT |
CRJH | Switch Actuator Indexing Position Quantity | 16 SINGLE ACTUATOR |
CSLC | Switch Actuator Positioning Increment | 22.5 DEGREES SINGLE ACTUATOR |
CTDN | Switch Actuator Stop Device Type | FIXED STOP SINGLE ACTUATOR |
AJZE | Switch Contact Basic Design | NONPILE-UP NONSYMMETRICAL |
CSCF | Terminal Type | TAB, SOLDER LUG |
AAJD | Thread Class | 2A SINGLE MOUNTING FACILITY |
AASA | Thread Length | 0.437 INCHES NOMINAL SINGLE MOUNTING FACILITY |