| Manufacturer Part Number | RNCC | RNVC | Manufacturer Name | CAGE | |
|---|---|---|---|---|---|
| MS21347-F271 | 2 - Definitive Specification or Standard Document | 2 - Production Item | MILITARY STANDARDS | 96906 | |
Definitive Government Specification or Standard Designator Reference. A part number, style number, or type designator included in or developed in accordance with a Government specification or standard which has the effect of fully identifying an item of supply. This code shall also be used for a Government specification or standard which, although not including part numbers, style numbers, or type designators, covers a single item of upply. These reference numbers may be coded with Reference Number Variation Code (RNVC) 1 in accordance with volume 2, paragraph 2.9.2.n.(4).
A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.
| FSG | FSC | NIIN | FIIG | INC | CRITICALITY | TYPE OF ITEM | MRC | DEMIL | HMIC | EDC | PMIC | ADPEC | DATE CREATED |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 59 | 5930 | 014228177 | A053A0 | 00184 | X | 1 | A | P | A | A | 0 | 8 Dec 1995 |
The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Full Descriptive Item Identification
Non-MLI/ Non-SLI — Demilitarization not required.
Indicates there is no information in the HMIRS; however, the NSN is in a FSC in Table II of Federal Standard 313 and a MSDS may be required by the user. The requirement for a MSDS is dependent on a hazard determination of the supplier or the intended end use of the product.
No known Electrostatic Discharge (ESD) or Electromagnetic Interference (EMI) sensitivity.
Item does not contain Precious Metal.
Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9)
| MOE Rule | Former MOE | AMC | AMSC | NIMSC | IMC | IMC Activity | AAC | DSOR | Collaborators | Receivers | Effective Date | |||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| ZC01 | 1 Dec 1995 | |||||||||||||||||||||||||||||
| RNFC | RNCC | RNVC | DAC | RNAAC | RNSC | RNJC | SADC | MSDS | HCC | Reference Number | CAGE | |
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 2 | 2 | 4 | 9Z | D | MS21347-F271 | 96906 | | |||||
Definitive Government Specification or Standard Designator Reference. A part number, style number, or type designator included in or developed in accordance with a Government specification or standard which has the effect of fully identifying an item of supply. This code shall also be used for a Government specification or standard which, although not including part numbers, style numbers, or type designators, covers a single item of upply. These reference numbers may be coded with Reference Number Variation Code (RNVC) 1 in accordance with volume 2, paragraph 2.9.2.n.(4).
A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.
The reference number is represented by technical documentation other than a drawing and the documentation was available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number; however, the RNAAC cannot furnish the technical documentation.
DLIS-K, Battle Creek, MI 49037-3084
Procurement authority of the manufacturer and reference number have not yet been checked. NOTE: This code is to be allocated to reference numbers still requiring checks on procurement authority.
| ISC | Originator | NIIN Status | Replaced / Replacement ISC | Replaced / Replacement Originator | Replacement NIIN Status | Replacement Date | Replaced / Replacement NSN | Decision Date |
|---|---|---|---|---|---|---|---|---|
| 5 | 97 | 0 | 8 Dec 1995 |
An item authorized for procurement that has not yet been subject to item standardization.
DLIS-LFF, Battle Creek, MI 49037-3084
Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.
| Integrity | Originating | HMC | LCL | WCC | TCC | SHC | ADC | ACC | ASH | LTL | NMFC | NMFC Sub Item | UFC | Freight Description | Rail Variance |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| ZC |
Canada
No Variation. NMFC and UFCC Match.
| MRC | Decoded Requirement | Clear Text Reply |
|---|---|---|
| AFUS | Actuator Height | 0.983 INCHES NOMINAL |
| AFUR | Actuator Diameter | 0.430 INCHES MAXIMUM |
| AFUX | Actuator Position-Action Relationship | UP POSITION MOMENTARY AND DOWN POSITION MOMENTARY AND CENTER POSITION MAINTAINED |
| AFUY | Actuator Position-Locking Relationship | CENTER POSITION LOCKED IN |
| AFUQ | Actuator Style | ROUND |
| ABPM | Body Diameter | 0.670 INCHES MAXIMUM |
| ADAQ | Body Length | 1.260 INCHES MAXIMUM |
| AAQL | Body Style | BUSHING MOUNT |
| ABXD | Bushing Length | 0.469 INCHES NOMINAL |
| CXQR | Contact Load Current Rating At Maximum Rated Voltage | 2.000 AMPERES RESISTIVE AC AND 5.000 AMPERES INDUCTIVE DC |
| AFXE | Maximum Voltage Rating In Volts | 115.0 AC AND 28.0 DC |
| AXGY | Mounting Method | THREADED BUSHING |
| CQJX | Nominal Thread Size | 0.469 INCHES |
| CRLD | Nonpile-Up Contact Arrangement | 2 POLE, DOUBLE THROW, TWO POSITIONS MOMENTARY SINGLE SWITCH UNIT |
| AKNA | Inclosure Type | FULLY INCLOSED |
| THSD | Thread Series Designator | UNS |
| CMLP | Thread Quantity Per Inch | 32 |
| ZZZK | Specification/Standard Data | 96906-MS21347 GOVERNMENT STANDARD |
| TTQY | Terminal Type And Quantity | 6 SOCKET, INTEGRATED WIRE TERMINATION |
| AAJD | Thread Class | 2A |