| Manufacturer Part Number | RNCC | RNVC | Manufacturer Name | CAGE | |
|---|---|---|---|---|---|
| 8510K11 | 3 - Design Control Reference | 2 - Production Item | EATON CORPORATION | 81640 | |
| 8510K11 | 3 - Design Control Reference | 9 - No Longer Used | EATON CORP | 1DU88 | |
Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.
A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.
A specification, standard, or other reference number which is superseded, canceled, obsolete or discontinued and is coded Reference Number Category Code (RNCC) 5; a reference number for information only coded RNCC 6; or a reference number coded RNCC D.
| FSG | FSC | NIIN | FIIG | INC | CRITICALITY | TYPE OF ITEM | MRC | DEMIL | HMIC | EDC | PMIC | ADPEC | DATE CREATED |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 59 | 5930 | 014738941 | A053A0 | 00184 | X | 1 | A | P | A | A | 0 | 19 Apr 2000 |
The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Full Descriptive Item Identification
Non-MLI/ Non-SLI — Demilitarization not required.
Indicates there is no information in the HMIRS; however, the NSN is in a FSC in Table II of Federal Standard 313 and a MSDS may be required by the user. The requirement for a MSDS is dependent on a hazard determination of the supplier or the intended end use of the product.
No known Electrostatic Discharge (ESD) or Electromagnetic Interference (EMI) sensitivity.
Item does not contain Precious Metal.
Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9)
| MOE Rule | Former MOE | AMC | AMSC | NIMSC | IMC | IMC Activity | AAC | DSOR | Collaborators | Receivers | Effective Date | |||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| A918 | A196 | 5 | L | Z | CL | CL | 1 Nov 2005 | |||||||||||||||||||||||
| ZW01 | 1 Nov 2009 | |||||||||||||||||||||||||||||
| N9BN | 5 | L | Z | HD | 1 Jul 2012 | |||||||||||||||||||||||||
Acquire only from the prime contractor although the engineering data identifies the Commercial and Government Entity Code (CAGE) and part number of a source other than the prime contractor. The DoD activity assigning this code shall furnish the name and CAGE Code of the prime contractor to the activity responsible for acquiring the part.
The annual buy value of this part falls below the screening threshold of $10,000 but it has been screened for known source(s). (NOTE: This code shall not be used when screening parts entering the inventory. It shall not be assigned in preference to or supersede any other AMSC.) Valid AMCs: 1, 2, 3, 4 and 5.
Integrated Management: Relinquishment of Service management of an item in designated commodity oriented Federal Supply Classes to the IMM (FSC manager) for management.
U.S. Army Communications-Electronics, Fort Monmouth, NJ 07703-5006
Naval Inventory Control Point, Mechanicsburg, PA 17055-0788
U.S. Army Communications-Electronics, Fort Monmouth, NJ 07703-5006
Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.
A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.
The reference number is represented by a drawing, but the drawing was not available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number.
USA
A specification, standard, or other reference number which is superseded, canceled, obsolete or discontinued and is coded Reference Number Category Code (RNCC) 5; a reference number for information only coded RNCC 6; or a reference number coded RNCC D.
The reference number is represented by a drawing and the drawing was available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number; however, the RNAAC cannot furnish the drawing.
| ISC | Originator | NIIN Status | Replaced / Replacement ISC | Replaced / Replacement Originator | Replacement NIIN Status | Replacement Date | Replaced / Replacement NSN | Decision Date |
|---|---|---|---|---|---|---|---|---|
| 5 | 97 | 0 | 19 Apr 2000 |
An item authorized for procurement that has not yet been subject to item standardization.
DLIS-LFF, Battle Creek, MI 49037-3084
Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.
| Integrity | Originating | HMC | LCL | WCC | TCC | SHC | ADC | ACC | ASH | LTL | NMFC | NMFC Sub Item | UFC | Freight Description | Rail Variance |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| TH | 72D | Z | 9 | A | H | Z | P | 061300 | X | 34410 | CIRCUIT-BREAKER-SWITCH-NOI |
Defense Supply Center Columbus, Columbus, OH 43215
Communications/Electronics, other than SIGINT/EW or COMSEC. Repair Parts and Components
No special type of cargo code applicable
No special handling required
Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
No special handling required.
77.5
No Variation. NMFC and UFCC Match.
Defense Logistics Agency, Enterprise Business Systems
INSURANCE/NUMERIC STOCKAGE OBJECTIVE ITEM. Items which may be required occasionally or intermittently, and prudence requires that a nominal quantity of materiel be stocked due to the essentiality or the lead time of the item. 1. The item is centrally managed, stocked, and issued. 2. Requisitions will be submitted in accordance with IMM/Service requisitioning procedures.
Unclassified
No QUP
ARMY: This is a nonreparable item. If condemned or economically unserviceable, then dispose at the level authorized replace the item; MARINE CORPS: Nonreparable item. When unserviceable, condemn and dispose at the level indicated by the first digit of the maintenance code; NAVY: Special Program Consumables
Each - A numeric quantity of one item of supply. Do not use if a more specific term applies, such as kit, set, assortment, assembly, group, sheet, plate, strip or length.
TYPE I or TYPE II (Non-Deteriorative/No Shelf-Life) - An individual item of supply which is determined through an evaluation of technical test data and/or actual experience to be an item with a definite non-extendible period of shelf-life OR An individual item of supply having an assigned shelf-life time period that may be extended after completion of inspection/test/restorative action.
AIR FORCE ERRC XB3: Stock Fund (Except Munitions); DLA: This item has been reviewed and a determination made that the item cannot or should not be restored to a serviceable condition from an unserviceable condition; NAVY: 1I cog not stocked print on demand flat forms
Department of the Army
Department of the Navy
Defense Logistics Agency
| MRC | Decoded Requirement | Clear Text Reply |
|---|---|---|
| AFUS | Actuator Height | 0.690 INCHES NOMINAL |
| AFUR | Actuator Diameter | 0.240 INCHES NOMINAL |
| AFUX | Actuator Position-Action Relationship | UP POSITION MAINTAINED AND DOWN POSITION MAINTAINED |
| AFUQ | Actuator Style | ROUND |
| ADAU | Body Height | 0.920 INCHES NOMINAL |
| ADAQ | Body Length | 1.150 INCHES NOMINAL |
| AAQL | Body Style | BUSHING MOUNT |
| ADAT | Body Width | 0.594 INCHES NOMINAL |
| ABXD | Bushing Length | 0.468 INCHES NOMINAL |
| CXQR | Contact Load Current Rating At Maximum Rated Voltage | 15.000 AMPERES RESISTIVE AC AND 15.000 AMPERES RESISTIVE DC |
| AFXE | Maximum Voltage Rating In Volts | 115.0 AC OR 28.0 DC |
| AJWX | Mounting Surface To Terminal End Distance | 1.170 INCHES NOMINAL |
| AXGY | Mounting Method | THREADED BUSHING |
| CQJX | Nominal Thread Size | 0.469 INCHES |
| AKNA | Inclosure Type | FULLY INCLOSED |
| THSD | Thread Series Designator | UNS |
| CMLP | Thread Quantity Per Inch | 32 |
| TTQY | Terminal Type And Quantity | 3 SCREW |
| AAJD | Thread Class | 2A |