Manufacturer Part Number | RNCC | RNVC | Manufacturer Name | CAGE | |
---|---|---|---|---|---|
3LO-453C/3 | 3 - Design Control Reference | 2 - Production Item | INERTIA SWITCH, INC. | 21928 | ![]() |
Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.
A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.
FSG | FSC | NIIN | FIIG | INC | CRITICALITY | TYPE OF ITEM | MRC | DEMIL | HMIC | EDC | PMIC | ADPEC | DATE CREATED |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
59 | 5930 | 015203392 | A048B0 | 02016 | X | 4 | 6 | A | P | A | A | 0 | 7 May 2004 |
The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Partial Descriptive Item Identification (Type 1 Concept)
An approved item name and FIIG may exist, but it has previously been established and documented that industry refuses to provide the technical data sufficient for preparation on a full descriptive method item identification based on policy, restricted or proprietary data rights, nonexistence of technical data, etc.
Non-MLI/ Non-SLI — Demilitarization not required.
Indicates there is no information in the HMIRS; however, the NSN is in a FSC in Table II of Federal Standard 313 and a MSDS may be required by the user. The requirement for a MSDS is dependent on a hazard determination of the supplier or the intended end use of the product.
No known Electrostatic Discharge (ESD) or Electromagnetic Interference (EMI) sensitivity.
Item does not contain Precious Metal.
Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9)
MOE Rule | Former MOE | AMC | AMSC | NIMSC | IMC | IMC Activity | AAC | DSOR | Collaborators | Receivers | Effective Date | |||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
ZR01 | 1 May 2004 | |||||||||||||||||||||||||||||
ZU01 | 1 May 2008 | |||||||||||||||||||||||||||||
WI01 | 1 Jan 2010 | |||||||||||||||||||||||||||||
WR01 | 1 Dec 2011 | |||||||||||||||||||||||||||||
ZA01 | 1 Jan 2014 |
RNFC | RNCC | RNVC | DAC | RNAAC | RNSC | RNJC | SADC | MSDS | HCC | Reference Number | CAGE | |
---|---|---|---|---|---|---|---|---|---|---|---|---|
4 | 3 | 2 | 2 | 9Z | D | 3LO-453C/3 | 21928 | ![]() |
Number is totally in-the-clear (without modification) as originally configured by the manufacturer, design control activity, or supplier.
Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.
A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.
The reference number is represented by a drawing and the drawing was available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number; however, the RNAAC cannot furnish the drawing.
DLIS-K, Battle Creek, MI 49037-3084
Procurement authority of the manufacturer and reference number have not yet been checked. NOTE: This code is to be allocated to reference numbers still requiring checks on procurement authority.
ISC | Originator | NIIN Status | Replaced / Replacement ISC | Replaced / Replacement Originator | Replacement NIIN Status | Replacement Date | Replaced / Replacement NSN | Decision Date |
---|---|---|---|---|---|---|---|---|
6 | TX | 0 | 9 May 2004 |
An item authorized for procurement that is in a specific Federal Supply Class (FSC) or item name grouping consisting primarily of items which are one-of-a-kind; therefore, little or no potential exists for elimination of items through formal item reduction studies.
Defense Supply Center Columbus, Columbus, OH 43218
Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.
Integrity | Originating | HMC | LCL | WCC | TCC | SHC | ADC | ACC | ASH | LTL | NMFC | NMFC Sub Item | UFC | Freight Description | Rail Variance |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
AM |
U.S. Army Medical Materiel Agency, Frederick, MD 21701-5001
No Variation. NMFC and UFCC Match.
MRC | Decoded Requirement | Clear Text Reply |
---|---|---|
ADAU | Body Height | 1.200 INCHES MAXIMUM |
CTZB | Contact Voltage Rating In Volts | 125.0 AC AT ALTITUDE SECOND VOLTAGE |
CTZB | Contact Voltage Rating In Volts | 28.0 DC AT ALTITUDE FIRST VOLTAGE |
CQYJ | Mounting Facility Pattern | FOUR POSITION RECTANGULAR |
AXGY | Mounting Method | UNTHREADED HOLE |
STYL | Style Designator | RECTANGULAR W/MOUNTING LUGS |
AFDS | Longest Horizontal Distance Between Mounting Centers | 2.630 INCHES NOMINAL |
AFDT | Shortest Horizontal Distance Between Mounting Centers | 1.750 NOMINAL INCHES |
ABHP | Overall Length | 3.000 INCHES NOMINAL |
ABMK | Overall Width | 2.500 INCHES NOMINAL |
FEAT | Special Features | SENSITIVITY HEMISPHERICAL, LATCHING; G RANGE 2 - 20 G'S PORM 10 PCT; INSULATION RESISTANCE 500 MEGS MIN AT 500 VDC; CONTACT RATING 5 AMPS AT 28 VDC, 5 AMPS AT 125 VAC; CONTACT RESISTANCE LESS THAN 0.5 OHMS; MANUAL PUSH BUTTON RESET; SPST CONTACT TYPE; TERMINATION CONNECTOR MIL-C-26482, SER 1; SEAL HERMETICA, 1.0E-5 CC/SEC 90 NITROGEN, 10 PCT HELIUM; ALTITUDE METHOD 500.3-PROC 1; HIGH TEMP METHOD 501.3 PROC 1 AND 2, LOW TEMP METHOD 502.3 PROC 1 AND 2; TEMP SHOCK METHOD 503.3 PROC 1 AND 2; HUMIDITY METHOD 507.3 PROC 1 CYCLE 1; SALT FOG METHOD 509.3 PROC 2; SAND AND DUST METHOD 510.3 PROC 1 AND 2 FOR 4 HOURS; EXPLOSIVE ATMOS METHOD 511.3 PROC 1; VIBRATION METHOD 514.2; SHOCK METHOD 516.2 PROC 1 |
SUPP | Supplementary Features | CALIBRATION SETTING IS ADJUSTED WHEN THE UNITS ARE MOUNTED FLAT; FOR UPWARD AND DOWNWARD ACCELERATION SENSING THE UNIT IS TO BE MOUNTED AT 45 DEG; WHEN MOUNTED AT 45 DEG THE ACCELERATION TRIGGER LEVEL WILL OBEY THE LAW OF COSINES; AXES UNIDIRECTIONAL |