5930-01-520-3392

SWITCH,INERTIA


5930-01-520-3392 (5930015203392, 015203392)
Part Number (1 listing): 3LO-453C/3
Summary

FSG 59 / FSC 5930

DEMIL: A

DEMIL INT: 1

HMIC: P

Date Created: 7 May 2004

MSDS: None

Hazmat: None

Request a Quote


;



MASTER CROSS REFERENCE LIST (MCRL) | NSN 5930-01-520-3392 Submit RFQ
Manufacturer Part NumberRNCCRNVCManufacturer NameCAGE
3LO-453C/33 - Design Control Reference2 - Production ItemINERTIA SWITCH, INC.  21928      
Code Definitions

3 - Design Control Reference

Reference Number Category Code (DRN_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

2 - Production Item

Reference Number Variation Code (DRN_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.


FLIS - SEG A - IDENTIFICATION | NSN 5930-01-520-3392 Submit RFQ
FSGFSCNIINFIIGINCCRITICALITYTYPE OF ITEMMRCDEMILHMICEDCPMICADPECDATE CREATED
595930015203392A048B002016X46APAA07 May 2004
Code Definitions

59

Federal Supply Group (FSG_3994/FSC_WI_FSG_3996)


Electrical and Electronic Equipment Components

5930

Federal Supply Class (FSC_3994/FSC_WI_FSC_3996)


Switches

015203392

National Item Identification Number (NCB_CD_4130/I_I_NBR_4131)


NSN 5930-01-520-3392

A048B0

Federal Item Identification Guide (FIIG_4065)

02016

Item Naming Code (INC_4080)

7 May 2004

NIIN Assignment Date (DT_NIIN_ASGMT_2180)

X

Item Criticality (CRITL_CD_FIIG_3843)


The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.

4

Type of Item Identification (TYP_II_4820)


Partial Descriptive Item Identification (Type 1 Concept)

6

Reference / Partial Descriptive Method Reason Code (RPDMRC_4765)


An approved item name and FIIG may exist, but it has previously been established and documented that industry refuses to provide the technical data sufficient for preparation on a full descriptive method item identification based on policy, restricted or proprietary data rights, nonexistence of technical data, etc.

A

Demilitarization Code (DEMIL_CD_0167)


Non-MLI/ Non-SLI — Demilitarization not required.

P

Hazardous Material Indicator Code (HMIC_0865)


Indicates there is no information in the HMIRS; however, the NSN is in a FSC in Table II of Federal Standard 313 and a MSDS may be required by the user. The requirement for a MSDS is dependent on a hazard determination of the supplier or the intended end use of the product.

A

Electrostatic Discharge Code (ESD_EMI_CD_2043)


No known Electrostatic Discharge (ESD) or Electromagnetic Interference (EMI) sensitivity.

A

Precious Metals Indicator Code (PMIC_0802)


Item does not contain Precious Metal.

0

ADPE Identification Code (ADPEC_0801)


Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9)


FLIS - SEG B - MOE RULE DATA | NSN 5930-01-520-3392 Submit RFQ
MOE RuleFormer MOEAMCAMSCNIMSCIMCIMC ActivityAACDSORCollaboratorsReceiversEffective Date
ZR011 May 2004
ZU011 May 2008
WI011 Jan 2010
WR011 Dec 2011
ZA011 Jan 2014
Code Definitions

FLIS - SEG C - REFERENCE NUMBER | NSN 5930-01-520-3392 Submit RFQ
RNFCRNCCRNVCDACRNAACRNSCRNJCSADCMSDSHCCReference NumberCAGE
43229ZD3LO-453C/3  21928  
Code Definitions

4

Reference Number Format Code (RNFC_2920)


Number is totally in-the-clear (without modification) as originally configured by the manufacturer, design control activity, or supplier.

3

Reference Number Category Code (RNCC_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

2

Reference Number Variation Code (RNVC_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.

2

Document Availability Code (DAC_2640)


The reference number is represented by a drawing and the drawing was available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number; however, the RNAAC cannot furnish the drawing.

9Z

Reference Number Action Activity Code (RNAAC_2900)


DLIS-K, Battle Creek, MI 49037-3084

D

Reference Number Status Code (RNSC_2923)


Procurement authority of the manufacturer and reference number have not yet been checked. NOTE: This code is to be allocated to reference numbers still requiring checks on procurement authority.


FLIS - SEG E - ITEM STANDARDIZATION DATA | NSN 5930-01-520-3392 Submit RFQ
ISCOriginatorNIIN StatusReplaced / Replacement ISCReplaced / Replacement OriginatorReplacement NIIN StatusReplacement DateReplaced / Replacement NSNDecision Date
6TX09 May 2004
Code Definitions

6

Item Standardization Code (ISC_2650)


An item authorized for procurement that is in a specific Federal Supply Class (FSC) or item name grouping consisting primarily of items which are one-of-a-kind; therefore, little or no potential exists for elimination of items through formal item reduction studies.

TX

Originator of Standardization Decision (ORG_STDZN_DEC_9325)


Defense Supply Center Columbus, Columbus, OH 43218

0

NIIN Status Code (NIIN_STAT_CD_2670)


Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.

9 May 2004

Standardization Decision Date (DT_STDZN_DEC_2300)


FLIS - SEG G - FREIGHT DATA | NSN 5930-01-520-3392 Submit RFQ
IntegrityOriginatingHMCLCLWCCTCCSHCADCACCASHLTLNMFCNMFC Sub ItemUFCFreight DescriptionRail Variance
AM
Code Definitions

AM

Originating Activity Code (ORIG_ACTY_CD_4210)


U.S. Army Medical Materiel Agency, Frederick, MD 21701-5001

Rail Variance

Rail Variance (RAIL_VARI_CD_4760)


No Variation. NMFC and UFCC Match.


FLIS - SEG M/V - CHARACTERISTICS DATA | NSN 5930-01-520-3392 Submit RFQ
MRCDecoded RequirementClear Text Reply
ADAUBody Height1.200 INCHES MAXIMUM
CTZBContact Voltage Rating In Volts125.0 AC AT ALTITUDE SECOND VOLTAGE
CTZBContact Voltage Rating In Volts28.0 DC AT ALTITUDE FIRST VOLTAGE
CQYJMounting Facility PatternFOUR POSITION RECTANGULAR
AXGYMounting MethodUNTHREADED HOLE
STYLStyle DesignatorRECTANGULAR W/MOUNTING LUGS
AFDSLongest Horizontal Distance Between Mounting Centers2.630 INCHES NOMINAL
AFDTShortest Horizontal Distance Between Mounting Centers1.750 NOMINAL INCHES
ABHPOverall Length3.000 INCHES NOMINAL
ABMKOverall Width2.500 INCHES NOMINAL
FEATSpecial FeaturesSENSITIVITY HEMISPHERICAL, LATCHING; G RANGE 2 - 20 G'S PORM 10 PCT; INSULATION RESISTANCE 500 MEGS MIN AT 500 VDC; CONTACT RATING 5 AMPS AT 28 VDC, 5 AMPS AT 125 VAC; CONTACT RESISTANCE LESS THAN 0.5 OHMS; MANUAL PUSH BUTTON RESET; SPST CONTACT TYPE; TERMINATION CONNECTOR MIL-C-26482, SER 1; SEAL HERMETICA, 1.0E-5 CC/SEC 90 NITROGEN, 10 PCT HELIUM; ALTITUDE METHOD 500.3-PROC 1; HIGH TEMP METHOD 501.3 PROC 1 AND 2, LOW TEMP METHOD 502.3 PROC 1 AND 2; TEMP SHOCK METHOD 503.3 PROC 1 AND 2; HUMIDITY METHOD 507.3 PROC 1 CYCLE 1; SALT FOG METHOD 509.3 PROC 2; SAND AND DUST METHOD 510.3 PROC 1 AND 2 FOR 4 HOURS; EXPLOSIVE ATMOS METHOD 511.3 PROC 1; VIBRATION METHOD 514.2; SHOCK METHOD 516.2 PROC 1
SUPPSupplementary FeaturesCALIBRATION SETTING IS ADJUSTED WHEN THE UNITS ARE MOUNTED FLAT; FOR UPWARD AND DOWNWARD ACCELERATION SENSING THE UNIT IS TO BE MOUNTED AT 45 DEG; WHEN MOUNTED AT 45 DEG THE ACCELERATION TRIGGER LEVEL WILL OBEY THE LAW OF COSINES; AXES UNIDIRECTIONAL


Back to Top