Manufacturer Part Number | RNCC | RNVC | Manufacturer Name | CAGE | |
---|---|---|---|---|---|
060-41-0266 | 3 - Design Control Reference | 2 - Production Item | DANFOSS FLUID POWER INC | 8Z296 | ![]() |
Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.
A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.
FSG | FSC | NIIN | FIIG | INC | CRITICALITY | TYPE OF ITEM | MRC | DEMIL | HMIC | EDC | PMIC | ADPEC | DATE CREATED |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
59 | 5930 | 015727047 | A048B0 | 00206 | X | 1 | A | P | A | A | 0 | 20 Mar 2009 |
The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Full Descriptive Item Identification
Non-MLI/ Non-SLI — Demilitarization not required.
Indicates there is no information in the HMIRS; however, the NSN is in a FSC in Table II of Federal Standard 313 and a MSDS may be required by the user. The requirement for a MSDS is dependent on a hazard determination of the supplier or the intended end use of the product.
No known Electrostatic Discharge (ESD) or Electromagnetic Interference (EMI) sensitivity.
Item does not contain Precious Metal.
Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9)
MOE Rule | Former MOE | AMC | AMSC | NIMSC | IMC | IMC Activity | AAC | DSOR | Collaborators | Receivers | Effective Date | |||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
ZN01 | 1 Mar 2009 |
RNFC | RNCC | RNVC | DAC | RNAAC | RNSC | RNJC | SADC | MSDS | HCC | Reference Number | CAGE | |
---|---|---|---|---|---|---|---|---|---|---|---|---|
4 | 3 | 2 | 4 | 9Z | D | 060-41-0266 | 8Z296 | ![]() |
Number is totally in-the-clear (without modification) as originally configured by the manufacturer, design control activity, or supplier.
Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.
A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.
The reference number is represented by technical documentation other than a drawing and the documentation was available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number; however, the RNAAC cannot furnish the technical documentation.
DLIS-K, Battle Creek, MI 49037-3084
Procurement authority of the manufacturer and reference number have not yet been checked. NOTE: This code is to be allocated to reference numbers still requiring checks on procurement authority.
ISC | Originator | NIIN Status | Replaced / Replacement ISC | Replaced / Replacement Originator | Replacement NIIN Status | Replacement Date | Replaced / Replacement NSN | Decision Date |
---|---|---|---|---|---|---|---|---|
5 | 97 | 0 | 20 Mar 2009 |
An item authorized for procurement that has not yet been subject to item standardization.
DLIS-LFF, Battle Creek, MI 49037-3084
Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.
Integrity | Originating | HMC | LCL | WCC | TCC | SHC | ADC | ACC | ASH | LTL | NMFC | NMFC Sub Item | UFC | Freight Description | Rail Variance |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
25 |
UNICOR-Federal Prison Industries, Washington, DC 20534
No Variation. NMFC and UFCC Match.
MRC | Decoded Requirement | Clear Text Reply |
---|---|---|
ADAU | Body Height | 103.0 MILLIMETERS NOMINAL |
CQGB | Contact Action Stimulus | DECREASE |
CTYC | Contact Adjustability | ACTUATION POINT ADJUSTABLE |
CTYM | Contact Adjustment Range | -40.00/+100.00 ACTUATION POINT DEGREES CELSIUS |
CTYS | Contact Adjustment Type | EXTERNAL ACTUATION POINT SCREW |
CTHF | Contact Load Current Rating | 10.0 AMPERES INDUCTIVE LOAD SINGLE VOLTAGE |
CTZB | Contact Voltage Rating In Volts | 220.0 AC AT SEA LEVEL SINGLE VOLTAGE |
AGAV | End Item Identification | SWITCH, PRESSURE |
MEDA | Media For Which Designed | GAS OR LIQUID |
CQYJ | Mounting Facility Pattern | TWO POSITION DIAGONAL |
AXGY | Mounting Method | BRACKET |
CRLD | Nonpile-Up Contact Arrangement | 2 POLE, SINGLE THROW, BOTH POSITIONS MAINTAINED |
AWTN | Operating Temp Rating | -40.0 DEG CELSIUS MINIMUM AND 100.0 DEG CELSIUS MAXIMUM |
STYL | Style Designator | RECTANGULAR W/BRACKET |
AJZC | Pressure Switch Type | ABSOLUTE |
ABKW | Overall Height | 116.0 MILLIMETERS NOMINAL |
ABHP | Overall Length | 116.0 MILLIMETERS NOMINAL |
ABMK | Overall Width | 68.0 MILLIMETERS NOMINAL |
CXCY | Part Name Assigned By Controlling Agency | PRESSURE SWITCHES AND THERMOSTATSTYPE KPS |
FEAT | Special Features | REFERENCE NUMBER INDICATES THAT ITEM COMES IN A PACK OF 12 |
AEBV | Unthreaded Mounting Hole Diameter | 7.0 MILLIMETERS NOMINAL |
SUPP | Supplementary Features | ITEM DOES NOT COME WITH EXTRA PARTS SUCH AS NUTS, BOLTS, OR COILS |
CSCF | Terminal Type | CONNECTOR, PLUG |