| Manufacturer Part Number | RNCC | RNVC | Manufacturer Name | CAGE | |
|---|---|---|---|---|---|
| D2VW-5L2A-1HS | 3 - Design Control Reference | 2 - Production Item | OMRON ELECTRONICS COMPONENTS LLC | 6CDP2 | |
Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.
A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.
| FSG | FSC | NIIN | FIIG | INC | CRITICALITY | TYPE OF ITEM | MRC | DEMIL | HMIC | EDC | PMIC | ADPEC | DATE CREATED |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 59 | 5930 | 015962813 | A053A0 | 00399 | X | 1 | A | P | A | A | 0 | 13 May 2011 |
The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Full Descriptive Item Identification
Non-MLI/ Non-SLI — Demilitarization not required.
Indicates there is no information in the HMIRS; however, the NSN is in a FSC in Table II of Federal Standard 313 and a MSDS may be required by the user. The requirement for a MSDS is dependent on a hazard determination of the supplier or the intended end use of the product.
No known Electrostatic Discharge (ESD) or Electromagnetic Interference (EMI) sensitivity.
Item does not contain Precious Metal.
Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9)
| MOE Rule | Former MOE | AMC | AMSC | NIMSC | IMC | IMC Activity | AAC | DSOR | Collaborators | Receivers | Effective Date | |||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| ZF01 | 1 May 2011 | |||||||||||||||||||||||||||||
| RNFC | RNCC | RNVC | DAC | RNAAC | RNSC | RNJC | SADC | MSDS | HCC | Reference Number | CAGE | |
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 4 | 3 | 2 | A | 9Z | D | D2VW-5L2A-1HS | 6CDP2 | | ||||
Number is totally in-the-clear (without modification) as originally configured by the manufacturer, design control activity, or supplier.
Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.
A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.
The reference number is represented by an engineering drawing and the drawing is available for unlimited use. The drawing will be furnished by the activity identified by the RNAAC upon request.
DLIS-K, Battle Creek, MI 49037-3084
Procurement authority of the manufacturer and reference number have not yet been checked. NOTE: This code is to be allocated to reference numbers still requiring checks on procurement authority.
| ISC | Originator | NIIN Status | Replaced / Replacement ISC | Replaced / Replacement Originator | Replacement NIIN Status | Replacement Date | Replaced / Replacement NSN | Decision Date |
|---|---|---|---|---|---|---|---|---|
| 5 | 97 | 0 | 13 May 2011 |
An item authorized for procurement that has not yet been subject to item standardization.
DLIS-LFF, Battle Creek, MI 49037-3084
Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.
| Integrity | Originating | HMC | LCL | WCC | TCC | SHC | ADC | ACC | ASH | LTL | NMFC | NMFC Sub Item | UFC | Freight Description | Rail Variance |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
No Variation. NMFC and UFCC Match.
| MRC | Decoded Requirement | Clear Text Reply |
|---|---|---|
| CRLD | Nonpile-Up Contact Arrangement | 1 POLE, DOUBLE THROW, ONE POSITION MOMENTARY SINGLE SWITCH UNIT |
| AFXE | Maximum Voltage Rating In Volts | 250.0 DC |
| CXQR | Contact Load Current Rating At Maximum Rated Voltage | 0.4 AMPERES RESISTIVE DC |
| AAQL | Body Style | HOLE MOUNTED |
| ABKQ | Center To Center Distance Between Mounting Facilities Parallel To Length | 19.4 MILLIMETERS NOMINAL |
| ADAQ | Body Length | 33.0 MILLIMETERS NOMINAL |
| ADAT | Body Width | 10.3 MILLIMETERS NOMINAL |
| ADAU | Body Height | 33.0 MILLIMETERS NOMINAL |
| AEBW | Center To Center Distance Between Mounting Facilities Parallel To Height | 10.3 MILLIMETERS NOMINAL |
| AFCG | Switch Actuator Quantity | 1 |
| AFUQ | Actuator Style | ROUND, FLUSH |
| AFUR | Actuator Diameter | 2.5 MILLIMETERS NOMINAL |
| AFUS | Actuator Height | 2.8 MILLIMETERS NOMINAL |
| TTQY | Terminal Type And Quantity | 3 QUICK DISCONNECT, MALE |
| CSJN | Switch Actuating Force | 200.0 GRAMS NOMINAL |
| CRRM | Switch Release Force | 30.0 GRAMS NOMINAL |
| CXQQ | Actuator Movement | 1.0 OVERTRAVEL MILLIMETERS NOMINAL |
| AKNA | Inclosure Type | HERMETICALLY SEALED |
| ABFE | Hazardous Locations/Environmental Protection | WATERTIGHT |
| AXGY | Mounting Method | PANEL |
| AEBV | Unthreaded Mounting Hole Diameter | 3.1 MILLIMETERS NOMINAL |
| FEAT | Special Features | OPERATING SPEED IS 0.1MM TO 1 MLS; OPERATING FREQUENCY IS 300 OPERATIONS A MINUTE (MECHANICAL) AND 30 OPERATIONS PER MINUTE (ELECTRICAL); AMBIENT OPERATING TEM IS -40 TO 85 DEGREES CELCIUS WITH NO ICING; AMBIENT OPERATING HUMIDITY IS 95% MAX (FOR 5 DEGREES C TO 35 DEGREES CELCIUS); TERMINALS USE AWG20 4L APPROVED LEAD WIRES; THREE TERMINALS ARE SOLDERED ON RIGHT SIDE OF SWITCH; 1ST TERMINAL IS 2.5MM FROM TOP; SECOND TERMINAL LEAD IS 5.3MM BELOW 1ST TERMINAL LEAD; THIRD TERMINAL LEAD IS 5.2M BELOW SECOND TERMINAL LEAD; OVERALL LENGTH TO INCLUDE TERMINAL WIRES IS 4.4MM |
| CXCY | Part Name Assigned By Controlling Agency | SEALED SNAP ACTION SWITCH D2VW |