| Manufacturer Part Number | RNCC | RNVC | Manufacturer Name | CAGE | |
|---|---|---|---|---|---|
| T9-MS2-22 | 3 - Design Control Reference | 2 - Production Item | OTTO ENGINEERING, INC. | 21649 | |
Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.
A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.
| FSG | FSC | NIIN | FIIG | INC | CRITICALITY | TYPE OF ITEM | MRC | DEMIL | HMIC | EDC | PMIC | ADPEC | DATE CREATED |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 59 | 5930 | 016232404 | A053A0 | 00184 | X | 4 | 3 | A | P | A | A | 0 | 6 Nov 2013 |
The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Partial Descriptive Item Identification (Type 1 Concept)
An approved item name and FIIG exist but the item involved is so unique in design that it cannot be fully described in accordance with the FIIG.
Non-MLI/ Non-SLI — Demilitarization not required.
Indicates there is no information in the HMIRS; however, the NSN is in a FSC in Table II of Federal Standard 313 and a MSDS may be required by the user. The requirement for a MSDS is dependent on a hazard determination of the supplier or the intended end use of the product.
No known Electrostatic Discharge (ESD) or Electromagnetic Interference (EMI) sensitivity.
Item does not contain Precious Metal.
Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9)
| MOE Rule | Former MOE | AMC | AMSC | NIMSC | IMC | IMC Activity | AAC | DSOR | Collaborators | Receivers | Effective Date | |||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| ZK01 | 1 Nov 2013 | |||||||||||||||||||||||||||||
| RNFC | RNCC | RNVC | DAC | RNAAC | RNSC | RNJC | SADC | MSDS | HCC | Reference Number | CAGE | |
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 4 | 3 | 2 | 4 | 9Z | D | T9-MS2-22 | 21649 | | ||||
Number is totally in-the-clear (without modification) as originally configured by the manufacturer, design control activity, or supplier.
Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.
A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.
The reference number is represented by technical documentation other than a drawing and the documentation was available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number; however, the RNAAC cannot furnish the technical documentation.
DLIS-K, Battle Creek, MI 49037-3084
Procurement authority of the manufacturer and reference number have not yet been checked. NOTE: This code is to be allocated to reference numbers still requiring checks on procurement authority.
| ISC | Originator | NIIN Status | Replaced / Replacement ISC | Replaced / Replacement Originator | Replacement NIIN Status | Replacement Date | Replaced / Replacement NSN | Decision Date |
|---|---|---|---|---|---|---|---|---|
| 5 | 97 | 0 | 6 Nov 2013 |
An item authorized for procurement that has not yet been subject to item standardization.
DLIS-LFF, Battle Creek, MI 49037-3084
Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.
| Integrity | Originating | HMC | LCL | WCC | TCC | SHC | ADC | ACC | ASH | LTL | NMFC | NMFC Sub Item | UFC | Freight Description | Rail Variance |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
No Variation. NMFC and UFCC Match.
| MRC | Decoded Requirement | Clear Text Reply |
|---|---|---|
| AFUS | Actuator Height | 0.690 INCHES NOMINAL |
| AFUR | Actuator Diameter | 0.240 INCHES NOMINAL |
| AFUQ | Actuator Style | ROUND |
| ADAU | Body Height | 1.100 INCHES NOMINAL |
| ADAQ | Body Length | 1.340 INCHES MAXIMUM |
| AAQL | Body Style | BUSHING MOUNT |
| ADAT | Body Width | 0.910 INCHES MAXIMUM |
| ABXD | Bushing Length | 0.470 INCHES NOMINAL |
| CXQR | Contact Load Current Rating At Maximum Rated Voltage | 20.0 AMPERES RESISTIVE DC AND 15.0 AMPERES INDUCTIVE DC AND 7.0 AMPERES LAMP DC AND 15.0 AMPERES RESISTIVE AC AND 10.0 AMPERES INDUCTIVE AC AND 4.0 AMPERES LAMP AC |
| AFXE | Maximum Voltage Rating In Volts | 28.0 DC AND 115.0 AC |
| AXGY | Mounting Method | THREADED BUSHING |
| AJWX | Mounting Surface To Terminal End Distance | 1.370 INCHES MAXIMUM |
| CQJX | Nominal Thread Size | 0.469 INCHES |
| AKNA | Inclosure Type | FULLY INCLOSED |
| CMLP | Thread Quantity Per Inch | 32 |
| THSD | Thread Series Designator | UNS |
| AFCG | Switch Actuator Quantity | 1 |
| TTQY | Terminal Type And Quantity | 6 SCREW |
| AAJD | Thread Class | 2A |