5935-00-038-5892

CONNECTOR,RECEPTACLE,ELECTRICAL


5935-00-038-5892 (5935000385892, 000385892)
Part Numbers (4 listings): DDM24W7P8 | DPM-24W7P-8 | 3023529-016-101 | 053515-0806 |
Summary

FSG 59 / FSC 5935

DEMIL: A

DEMIL INT: 1

HMIC: P

Date Created: 10 Nov 1972

Unit Weight: None

Unit Size: 2.7in x 0.6in x 0.8in

Unit Pack Cube: 0.001 cu ft

MSDS: None

Hazmat: None

Request a Quote


;



MASTER CROSS REFERENCE LIST (MCRL) | NSN 5935-00-038-5892 Submit RFQ
Manufacturer Part NumberRNCCRNVCManufacturer NameCAGE
DDM24W7P83 - Design Control Reference2 - Production ItemITT CORPORATION  71468    CAGE 71468  
DPM-24W7P-85 - Replaced / Discontinued1 - Incomplete Part NumberITT CORPORATION  71468    CAGE 71468  
3023529-016-1015 - Replaced / Discontinued2 - Production ItemLOCKHEED MARTIN CORPORATION  99696    CAGE 99696  
053515-08065 - Replaced / Discontinued9 - No Longer UsedITT CORPORATION  71468    CAGE 71468  
Code Definitions

3 - Design Control Reference

Reference Number Category Code (DRN_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

5 - Replaced / Discontinued

Reference Number Category Code (DRN_2910)


Secondary Reference. Any additional number, other than a primary number (codes 1,2,3,4) informative reference (code 6) or vendor item drawing reference (code 7) assigned to an item of production or supply by a commercial or Government organization, which represents the same item of production or supply to which the National Stock Number (NSN) was assigned. The reference number may have had an RNCC of 1, 2, 3, 4 or 7 but has since been replaced in the item-of-supply concept of the NSN by another primary number.

2 - Production Item

Reference Number Variation Code (DRN_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.

1 - Incomplete Part Number

Reference Number Variation Code (DRN_4780)


A design control or other reference number that does NOT identify an item of production without the use of additional information, or a specific part, type, or similar reference number does NOT identify or item of supply without the use of additional information.

9 - No Longer Used

Reference Number Variation Code (DRN_4780)


A specification, standard, or other reference number which is superseded, canceled, obsolete or discontinued and is coded Reference Number Category Code (RNCC) 5; a reference number for information only coded RNCC 6; or a reference number coded RNCC D.


FLIS - SEG A - IDENTIFICATION | NSN 5935-00-038-5892 Submit RFQ
FSGFSCNIINFIIGINCCRITICALITYTYPE OF ITEMMRCDEMILHMICEDCPMICADPECDATE CREATED
595935000385892A039B015093X1APC10 Nov 1972
Code Definitions

59

Federal Supply Group (FSG_3994/FSC_WI_FSG_3996)


Electrical and Electronic Equipment Components

5935

Federal Supply Class (FSC_3994/FSC_WI_FSC_3996)


Connectors, Electrical

000385892

National Item Identification Number (NCB_CD_4130/I_I_NBR_4131)


NSN 5935-00-038-5892

A039B0

Federal Item Identification Guide (FIIG_4065)

15093

Item Naming Code (INC_4080)

10 Nov 1972

NIIN Assignment Date (DT_NIIN_ASGMT_2180)

X

Item Criticality (CRITL_CD_FIIG_3843)


The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.

1

Type of Item Identification (TYP_II_4820)


Full Descriptive Item Identification

A

Demilitarization Code (DEMIL_CD_0167)


Non-MLI/ Non-SLI — Demilitarization not required.

P

Hazardous Material Indicator Code (HMIC_0865)


Indicates there is no information in the HMIRS; however, the NSN is in a FSC in Table II of Federal Standard 313 and a MSDS may be required by the user. The requirement for a MSDS is dependent on a hazard determination of the supplier or the intended end use of the product.

C

Precious Metals Indicator Code (PMIC_0802)


Item contains combination of two or more precious metals (silver, gold, platinum).


FLIS - SEG B - MOE RULE DATA | NSN 5935-00-038-5892 Submit RFQ
MOE RuleFormer MOEAMCAMSCNIMSCIMCIMC ActivityAACDSORCollaboratorsReceiversEffective Date
YD011 Apr 1991
ZS011 Apr 1991
Code Definitions

FLIS - SEG C - REFERENCE NUMBER | NSN 5935-00-038-5892 Submit RFQ
RNFCRNCCRNVCDACRNAACRNSCRNJCSADCMSDSHCCReference NumberCAGE
3321TXDDDM24W7P8  71468   CAGE/71468
1511TXDDPM-24W7P-8  71468   CAGE/71468
45249ZD3023529-016-101  99696   CAGE/99696
1591TXB053515-0806  71468   CAGE/71468
Code Definitions

3

Reference Number Format Code (RNFC_2920)


Number format is unknown. (Coded RNFC 3 by the Defense Logistics Information Service upon implementation of FLIS.)

3

Reference Number Category Code (RNCC_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

2

Reference Number Variation Code (RNVC_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.

1

Document Availability Code (DAC_2640)


The reference number is represented by a drawing and the drawing was available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number. The RNAAC will furnish the drawing upon request.

TX

Reference Number Action Activity Code (RNAAC_2900)


Defense Supply Center Columbus, Columbus, OH 43218

D

Reference Number Status Code (RNSC_2923)


Procurement authority of the manufacturer and reference number have not yet been checked. NOTE: This code is to be allocated to reference numbers still requiring checks on procurement authority.

1

Reference Number Format Code (RNFC_2920)


Number is formatted as configured on the originating document with the exception of the modification required in volume 2, chapter 2.9.Number is formatted as configured on the originating document with the exception of the modification required in volume 2, chapter 2.9 .

5

Reference Number Category Code (RNCC_2910)


Secondary Reference. Any additional number, other than a primary number (codes 1,2,3,4) informative reference (code 6) or vendor item drawing reference (code 7) assigned to an item of production or supply by a commercial or Government organization, which represents the same item of production or supply to which the National Stock Number (NSN) was assigned. The reference number may have had an RNCC of 1, 2, 3, 4 or 7 but has since been replaced in the item-of-supply concept of the NSN by another primary number.

1

Reference Number Variation Code (RNVC_4780)


A design control or other reference number that does NOT identify an item of production without the use of additional information, or a specific part, type, or similar reference number does NOT identify or item of supply without the use of additional information.

4

Reference Number Format Code (RNFC_2920)


Number is totally in-the-clear (without modification) as originally configured by the manufacturer, design control activity, or supplier.

4

Document Availability Code (DAC_2640)


The reference number is represented by technical documentation other than a drawing and the documentation was available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number; however, the RNAAC cannot furnish the technical documentation.

9Z

Reference Number Action Activity Code (RNAAC_2900)


DLIS-K, Battle Creek, MI 49037-3084

9

Reference Number Variation Code (RNVC_4780)


A specification, standard, or other reference number which is superseded, canceled, obsolete or discontinued and is coded Reference Number Category Code (RNCC) 5; a reference number for information only coded RNCC 6; or a reference number coded RNCC D.

B

Reference Number Status Code (RNSC_2923)


Manufacturer and/or reference number are not authorized for procurement. NOTE: This code may be used for obsolete or informative reference numbers only.


FLIS - SEG E - ITEM STANDARDIZATION DATA | NSN 5935-00-038-5892 Submit RFQ
ISCOriginatorNIIN StatusReplaced / Replacement ISCReplaced / Replacement OriginatorReplacement NIIN StatusReplacement DateReplaced / Replacement NSNDecision Date
2TX01 Dec 1974
Code Definitions

2

Item Standardization Code (ISC_2650)


An item authorized for procurement which has been included in an item reduction study and which initially does not replace an item not authorized for procurement. In addition, in generic relationships, a code 2 item is related to a code 1 item.

TX

Originator of Standardization Decision (ORG_STDZN_DEC_9325)


Defense Supply Center Columbus, Columbus, OH 43218

0

NIIN Status Code (NIIN_STAT_CD_2670)


Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.

1 Dec 1974

Standardization Decision Date (DT_STDZN_DEC_2300)


FLIS - SEG G - FREIGHT DATA | NSN 5935-00-038-5892 Submit RFQ
IntegrityOriginatingHMCLCLWCCTCCSHCADCACCASHLTLNMFCNMFC Sub ItemUFCFreight DescriptionRail Variance
TX658Z9AHZW061680Z34570ELEC-WIRING-PLUGS-ETC
Code Definitions

TX

Originating Activity Code (ORIG_ACTY_CD_4210)


Defense Supply Center Columbus, Columbus, OH 43218

658

Water Commodity Code (WRT_CMDTY_CD_9275)


Electical Appliances, Small

Z

Type Cargo Code (TYPE_CGO_CD_9260)


No special type of cargo code applicable

9

Special Handling Code (SP_HDLG_CD_9240)


No special handling required

A

Air Dimension Code (AIR_DIM_CD_9220)


Shipment is not a consolidation and does not exceed 72 inches in any dimension.

H

Air Commodity Code (AIR_CMTY_HDLG_9215)


Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.

Z

Air Special Handling Code (AIR_CMTY_HDLG_9215)


No special handling required.

W

Less Than Truckload (CLAS_RTNG_CD_2770)


Variable Rating

061680

National Motor Freight Classification Number (NMFC Item Number) (NMFC_2850)

Z

NMFC Sub Item Number (SUB_ITM_NBR_0861)

34570

Uniform Freight Classification (UFC_CD_MODF_3040)

ELEC-WIRING-PLUGS-ETC

Freight Description (FRT_DESC_4020)

Rail Variance

Rail Variance (RAIL_VARI_CD_4760)


No Variation. NMFC and UFCC Match.


FLIS - SEG W - PACKAGING DATA | NSN 5935-00-038-5892 Submit RFQ
SourcePICA / SICAPackaging CategoryStoragePreservationClean/DryINT QtyUnit WeightUnit SizeUnit Pack CubeItem WeightItem Dims
PP411AAA2.7in x 0.6in x 0.8in0.001 cu ft
Preservation MaterialWrapping MaterialCushioning / DunnageCushioning ThicknessUnit ContainerIntermediate ContainerUnit Container LevelSpecial MarkingLevel A PackingLevel B PackingMinimal PackingOptional Procedure
0000NAXD300QQO
Code Definitions

P

Packaging Data Source Code (PK_DTA_SRC_CD_5148)


Primary Inventory Control Activity (PICA)

P

Primary / Secondary Inventory Control Code (PICA_SICA_IND_5099)


Primary Inventory Control Activity (PICA)

41

Method of Preservation Code (MTHD_PRSRV_CD_5160)


Watervaporproof bag, sealed

1

Cleaning and Drying Procedure Code (CLNG_DRY_PRC_5161)


Any suitable process that is not injurious to the item.

AAA

Intermediate Container Quantity (INTMD_CTN_QTY_5152)

Unit Pack Weight (UP_WT_5153)

2.7in x 0.6in x 0.8in

Unit Pack Size (UP_SZ_5154)

0.001 cu ft

Unit Pack Cube (UP_CU_5155)

00

Preservation Material Code (PRSRV_MAT_CD_5162)


No requirement

00

Wrapping Material Code (WRAP_MAT_CD_5163)


No requirement

NA

Cushioning and Dunnage Material Code (CUSH_DUN_MAT_5164)


PPP-C-795, cellular plastic film cushioning; or A-A-3129, open cell plastic cushioning; or PPP-C-1797, polypropylene foam cushioning; or A-A-59136, polyethylene foam cushioning

X

Thickness of Cushioning or Dunnage Code (THK_CUSH_DUN_5165)


As required to protect the item or elements of the package

D3

Intermediate Container Code (INTMD_CTNR_CD_5167)


PPP-B-566, PPP-B-676, or ASTM-D5118, folding, setup or fiberboard box.

00

Special Marking Code (SP_MKG_CD_5169)


No special marking

Q

Packing Requirement Code - For Level A (Maximum) Packing (LVL_A_PKG_CD_5170)


Packing shall be accomplished in accordance with table C.II for the packing level specified. Closure sealing and reinforcement shall be in accordance with applicable specification for shipping container.

Q

Packing Requirement Code - For Level B (Intermediate) Packing (LVL_B_PKG_CD_5171)


Packing shall be accomplished in accordance with table C-II for the packing level specified. Closure sealing and reinforcement shall be in accordance with the appropriate shipping container specification.

O

Optional Procedure Indicator Code (OPTNL_PRO_IND_5173)


Options can be exercised as to specific method of preservation or DoD approved packaging materials to be used. However, basic preservation method shall be retained, supplemental data shall be complied with, and unit package dimensions shall not be increased by more than one inch. Equal or better protection shall be given the item and there shall be no increase in the package cost.


FLIS - SEG M/V - CHARACTERISTICS DATA | NSN 5935-00-038-5892 Submit RFQ
MRCDecoded RequirementClear Text Reply
CQTZContact MaterialCOPPER ALLOY SINGLE MATING END SINGLE CONTACT GROUPING
AFRCContact Maximum Current Rating In Amps7.5 SINGLE MATING END SINGLE CONTACT GROUPING
AFQZContact RemovabilityNONREMOVABLE SINGLE MATING END SINGLE CONTACT GROUPING
AFQXContact Position Arrangement Style24W7 SINGLE MATING END
CQYHContact Surface TreatmentGOLD AND SILVER SINGLE MATING END SINGLE CONTACT GROUPING
AEJNDistance Between Mounting Facility Centers2.401 INCHES MINIMUM AND 2.411 INCHES MAXIMUM
AAQLBody StyleSTRAIGHT SHAPE
AFQWMating End Quantity1
CXCLIncluded Contact TypeROUND PIN SINGLE MATING END SINGLE CONTACT GROUPING
CXCGIncluded Contact Quantity24 SINGLE MATING END SINGLE CONTACT GROUPING
CTKLInsert Material Document And ClassificationMIL-M-14,TYPE SDG MIL SPEC SINGLE MATERIAL RESPONSE SINGLE MATING END
CQZGInsert MaterialPLASTIC DIALLYL PHTHALATE SINGLE MATING END
AFRNPolarization MethodMATING END
PMLCPrecious Material And LocationCONTACT SURFACES GOLD AND CONTACT SURFACES SILVER
PMWTPrecious Material And Weight0.024 GOLD GRAINS, TROY AND 0.024 SILVER GRAINS, TROY
PRMTPrecious MaterialGOLD AND SILVER
CSPTShell MaterialSTEEL
CSWMShell Surface TreatmentCADMIUM AND CHROMATE
AFRTShell TypeSOLID
ABKWOverall Height0.741 INCHES MINIMUM AND 0.831 INCHES MAXIMUM
ABHPOverall Length2.620 INCHES MINIMUM AND 2.650 INCHES MAXIMUM
ABMKOverall Width0.520 INCHES MINIMUM AND 0.590 INCHES MAXIMUM
AEBVUnthreaded Mounting Hole Diameter0.115 INCHES MINIMUM AND 0.125 INCHES MAXIMUM
CQTMTerminal LocationSIDE SINGLE MATING END SINGLE CONTACT GROUPING
CSCFTerminal TypePIN SINGLE MATING END SINGLE CONTACT GROUPING


Back to Top
Back to Top