5935-00-068-2228

CONNECTOR,RECEPTACLE,ELECTRICAL


5935-00-068-2228 (5935000682228, 000682228)
Part Number (1 listing): PT00CE18-32S
Summary

FSG 59 / FSC 5935

DEMIL: A

DEMIL INT: 1

HMIC: P

Date Created: 1 Jan 1963

Request a Quote


;



MASTER CROSS REFERENCE LIST (MCRL) | NSN 5935-00-068-2228 Submit RFQ
Manufacturer Part NumberRNCCRNVCManufacturer NameCAGE
PT00CE18-32S3 - Design Control Reference2 - Production ItemAMPHENOL CORPORATION  77820    CAGE 77820  
Code Definitions

3 - Design Control Reference

Reference Number Category Code (DRN_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

2 - Production Item

Reference Number Variation Code (DRN_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.


FLIS - SEG A - IDENTIFICATION | NSN 5935-00-068-2228 Submit RFQ
FSGFSCNIINFIIGINCCRITICALITYTYPE OF ITEMMRCDEMILHMICEDCPMICADPECDATE CREATED
595935000682228A039B015093XKAPG1 Jan 1963
Code Definitions

59

Federal Supply Group (FSG_3994/FSC_WI_FSG_3996)


Electrical and Electronic Equipment Components

5935

Federal Supply Class (FSC_3994/FSC_WI_FSC_3996)


Connectors, Electrical

000682228

National Item Identification Number (NCB_CD_4130/I_I_NBR_4131)


NSN 5935-00-068-2228

A039B0

Federal Item Identification Guide (FIIG_4065)

15093

Item Naming Code (INC_4080)

1 Jan 1963

NIIN Assignment Date (DT_NIIN_ASGMT_2180)

X

Item Criticality (CRITL_CD_FIIG_3843)


The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.

K

Type of Item Identification (TYP_II_4820)


Full Descriptive - Reference Item Identification

A

Demilitarization Code (DEMIL_CD_0167)


Non-MLI/ Non-SLI — Demilitarization not required.

P

Hazardous Material Indicator Code (HMIC_0865)


Indicates there is no information in the HMIRS; however, the NSN is in a FSC in Table II of Federal Standard 313 and a MSDS may be required by the user. The requirement for a MSDS is dependent on a hazard determination of the supplier or the intended end use of the product.

G

Precious Metals Indicator Code (PMIC_0802)


Item contains gold.


FLIS - SEG B - MOE RULE DATA | NSN 5935-00-068-2228 Submit RFQ
MOE RuleFormer MOEAMCAMSCNIMSCIMCIMC ActivityAACDSORCollaboratorsReceiversEffective Date
YJ
ZE
ZG
ZR
ZW
ZG011 Apr 1991
ZE011 Apr 1991
YJ011 Apr 1991
ZW011 Dec 1995
ZR011 Jul 1997
Code Definitions

FLIS - SEG G - FREIGHT DATA | NSN 5935-00-068-2228 Submit RFQ
IntegrityOriginatingHMCLCLWCCTCCSHCADCACCASHLTLNMFCNMFC Sub ItemUFCFreight DescriptionRail Variance
723Z9AHZW061680Z34570ELEC-WIRING-PLUGS-ETC
Code Definitions

XX

Originating Activity Code (ORIG_ACTY_CD_4210)


723

Water Commodity Code (WRT_CMDTY_CD_9275)


Radio Parts, Batteries and Equipment, excluding Tubes Packed separately

Z

Type Cargo Code (TYPE_CGO_CD_9260)


No special type of cargo code applicable

9

Special Handling Code (SP_HDLG_CD_9240)


No special handling required

A

Air Dimension Code (AIR_DIM_CD_9220)


Shipment is not a consolidation and does not exceed 72 inches in any dimension.

H

Air Commodity Code (AIR_CMTY_HDLG_9215)


Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.

Z

Air Special Handling Code (AIR_CMTY_HDLG_9215)


No special handling required.

W

Less Than Truckload (CLAS_RTNG_CD_2770)


Variable Rating

061680

National Motor Freight Classification Number (NMFC Item Number) (NMFC_2850)

Z

NMFC Sub Item Number (SUB_ITM_NBR_0861)

34570

Uniform Freight Classification (UFC_CD_MODF_3040)

ELEC-WIRING-PLUGS-ETC

Freight Description (FRT_DESC_4020)

Rail Variance

Rail Variance (RAIL_VARI_CD_4760)


No Variation. NMFC and UFCC Match.


FLIS - SEG H - MANAGEMENT DATA | NSN 5935-00-068-2228 Submit RFQ
Unit PriceMOESOSAACCIICQUPReparabilityUISLC
DNS9EYU1EA0
Code Definitions

S9E

Source of Supply (SOS_CD_3690) or Source of Supply Modifier (SOSM_CD_2948)


DLA Land and Maritime, Columbus, OH 43218 ** No longer valid for input **

Y

Acquisition Advice Code (AAC_2507)


TERMINAL ITEM (NON-STOCKED ITEMS) Future procurement is not authorized. No wholesale stock is available for issue. 1. Requisitions will not be processed to the wholesale manager. 2. Internal Service/agency requisitioning may be continued in accordance with the Service/agency requisitioning policies.

U

Controlled Item Inventory Code (CIIC_2863)


Unclassified

1

Quantity Unit Pack (QUP_6106)


1

EA

Unit of Issue (UI_3050)


Each - A numeric quantity of one item of supply. Do not use if a more specific term applies, such as kit, set, assortment, assembly, group, sheet, plate, strip or length.

0

Shelf Life Code (SLC_2943)


TYPE I or TYPE II (Non-Deteriorative/No Shelf-Life) - An individual item of supply which is determined through an evaluation of technical test data and/or actual experience to be an item with a definite non-extendible period of shelf-life OR An individual item of supply having an assigned shelf-life time period that may be extended after completion of inspection/test/restorative action.

DN

Service / Agency Code (MOE_CD_2833)


Department of the Navy


FLIS - SEG M/V - CHARACTERISTICS DATA | NSN 5935-00-068-2228 Submit RFQ
MRCDecoded RequirementClear Text Reply
AFQKDistance From Mounting Shoulder To Front Face0.431 INCHES MINIMUM AND 0.441 INCHES MAXIMUM
CXCJBushing Accommodation Hole ShapeROUND
AEBWCenter To Center Distance Between Mounting Facilities Parallel To Height1.062 INCHES NOMINAL
AFRVConnector Locking MethodBAYONET PIN
CQTZContact MaterialCOPPER ALLOY SINGLE MATING END SINGLE CONTACT GROUPING
AFRDContact Maximum Ac Voltage Rating In Volts500.0 SINGLE MATING END SINGLE CONTACT GROUPING
AFRCContact Maximum Current Rating In Amps7.5 SINGLE MATING END SINGLE CONTACT GROUPING
AFQZContact RemovabilityREMOVABLE SINGLE MATING END SINGLE CONTACT GROUPING
AFREContact Maximum Dc Voltage Rating In Volts700.0 SINGLE MATING END SINGLE CONTACT GROUPING
AFQXContact Position Arrangement Style18-32 SINGLE MATING END
CQYHContact Surface TreatmentGOLD SINGLE MATING END SINGLE CONTACT GROUPING AND SILVER SINGLE MATING END SINGLE CONTACT GROUPING
AEHADistance Between Centerlines Of Mounting Facilities Parallel To Body Width1.062 INCHES NOMINAL
ADZCEnvironmental ProtectionMOISTURE PROOF
AAQLBody StyleSTRAIGHT SHAPE, EXTERNAL COUPLING W/BACKSHELL
AFQWMating End Quantity1
PMLCPrecious Material And LocationCONTACT SURFACES GOLD AND CONTACT SURFACES SILVER
CXCGIncluded Contact Quantity32 SINGLE MATING END SINGLE CONTACT GROUPING
CXCLIncluded Contact TypeROUND SOCKET SINGLE MATING END SINGLE CONTACT GROUPING
CQZGInsert MaterialRUBBER SINGLE MATING END
AFRPInsert Position In Deg0.0
AFRNPolarization MethodKEYWAY OR MULTIPLE KEYWAY
PMWTPrecious Material And Weight0.032 GOLD GRAINS, TROY AND 0.032 SILVER GRAINS, TROY
PRMTPrecious MaterialGOLD AND SILVER
CSPTShell MaterialALUMINUM ALLOY
CSWMShell Surface TreatmentCADMIUM AND CHROMATE
AFRTShell TypeSOLID
ABKWOverall Height1.296 INCHES MINIMUM AND 1.328 INCHES MAXIMUM
ABHPOverall Length1.656 INCHES MAXIMUM
ABMKOverall Width1.296 INCHES MINIMUM AND 1.328 INCHES MAXIMUM
AEBVUnthreaded Mounting Hole Diameter0.115 INCHES MINIMUM AND 0.125 INCHES MAXIMUM
CQTMTerminal LocationBACK SINGLE MATING END SINGLE CONTACT GROUPING
CSCFTerminal TypeCRIMP SINGLE MATING END SINGLE CONTACT GROUPING


Back to Top
Back to Top