Manufacturer Part Number | RNCC | RNVC | Manufacturer Name | CAGE | |
---|---|---|---|---|---|
330830 | 3 - Design Control Reference | 2 - Production Item | TYCO ELECTRONICS CORPORATION | 00779 | ![]() |
Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.
A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.
FSG | FSC | NIIN | FIIG | INC | CRITICALITY | TYPE OF ITEM | MRC | DEMIL | HMIC | EDC | PMIC | ADPEC | DATE CREATED |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
59 | 5935 | 000894955 | A039B0 | 01938 | X | 1 | A | P | A | G | 20 Jun 1967 |
The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Full Descriptive Item Identification
Non-MLI/ Non-SLI — Demilitarization not required.
Indicates there is no information in the HMIRS; however, the NSN is in a FSC in Table II of Federal Standard 313 and a MSDS may be required by the user. The requirement for a MSDS is dependent on a hazard determination of the supplier or the intended end use of the product.
No known Electrostatic Discharge (ESD) or Electromagnetic Interference (EMI) sensitivity.
Item contains gold.
MOE Rule | Former MOE | AMC | AMSC | NIMSC | IMC | IMC Activity | AAC | DSOR | Collaborators | Receivers | Effective Date | |||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
ZZ | ||||||||||||||||||||||||||||||
G860 | 0 | 0 | C | 1 Apr 1991 | ||||||||||||||||||||||||||
G880 | 0 | 0 | C | 1 Apr 1991 | ||||||||||||||||||||||||||
MC49 | 3 | A | Z | PA | 1 Nov 2005 | |||||||||||||||||||||||||
C911 | 3 | A | 1 Nov 2005 | |||||||||||||||||||||||||||
FXGX | 3 | A | Z | SX | 1 Nov 2005 | |||||||||||||||||||||||||
N9BN | 3 | A | Z | GH | GG | 1 Dec 2013 |
Not Established
SERVICE/AGENCY-MANAGED (Service/Agency use only.) Issue, transfer, or shipment is not subject to specialized controls other than those imposed by individual Services supply policy. 1. The item is centrally managed, stocked, and issued. 2. Requisitions will be submitted in accordance with Service requisitioning procedures.
Acquire directly from the actual manufacturer, whether or not the prime contractor is the actual manufacturer.
The Government's rights to use data in its possession is questionable. (NOTE: This code is only applicable to parts under immediate buy requirements and only as long as rights to data are still under review for resolution and appropriate recoding.) Valid AMCs: 1, 2, 3, 4 and 5.
Integrated Management: Relinquishment of Service management of an item in designated commodity oriented Federal Supply Classes to the IMM (FSC manager) for management.
Marine Corps Logistics Base, Albany, GA 31704-1128
Oklahoma City Air Logistics Center, Tinker AFB, OK 73145-3043
Naval Inventory Control Point, Mechanicsburg, PA 17055-0788
Naval Inventory Control Point, Philadelphia, PA 19111û5098
RNFC | RNCC | RNVC | DAC | RNAAC | RNSC | RNJC | SADC | MSDS | HCC | Reference Number | CAGE | |
---|---|---|---|---|---|---|---|---|---|---|---|---|
3 | 3 | 2 | 5 | TX | D | 330830 | 00779 | ![]() |
Number format is unknown. (Coded RNFC 3 by the Defense Logistics Information Service upon implementation of FLIS.)
Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.
A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.
The reference number is represented by a drawing, but the drawing was not available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number.
Defense Supply Center Columbus, Columbus, OH 43218
Procurement authority of the manufacturer and reference number have not yet been checked. NOTE: This code is to be allocated to reference numbers still requiring checks on procurement authority.
Integrity | Originating | HMC | LCL | WCC | TCC | SHC | ADC | ACC | ASH | LTL | NMFC | NMFC Sub Item | UFC | Freight Description | Rail Variance |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
TX | 658 | Z | 9 | A | H | Z | W | 061680 | Z | 34570 | ELEC-WIRING-PLUGS-ETC |
Defense Supply Center Columbus, Columbus, OH 43218
Electical Appliances, Small
No special type of cargo code applicable
No special handling required
Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
No special handling required.
Variable Rating
No Variation. NMFC and UFCC Match.
Unit Price | MOE | SOS | AAC | CIIC | QUP | Reparability | UI | SLC |
---|---|---|---|---|---|---|---|---|
DF | SMS | J | U | 1 | N | EA | 0 | |
DM | SMS | J | U | 1 | Z | EA | 0 | |
DN | SMS | J | U | 1 | EA | 0 | ||
DS | SMS | J | U | 1 | N | EA | 0 | |
GP | SMS | J | U | 1 | EA | 0 |
Defense Logistics Agency, Enterprise Business Systems
NOT STOCKED, CENTRALLY PROCURED # (NON-STOCKED ITEMS) IMM/Service centrally managed but not stocked item. Procurement will be initiated only after receipt of a requisition.
Unclassified
1
AIR FORCE ERRC XB3: Stock Fund (Except Munitions); DLA: This item has been reviewed and a determination made that the item cannot or should not be restored to a serviceable condition from an unserviceable condition; NAVY: 1I cog not stocked print on demand flat forms
Each - A numeric quantity of one item of supply. Do not use if a more specific term applies, such as kit, set, assortment, assembly, group, sheet, plate, strip or length.
TYPE I or TYPE II (Non-Deteriorative/No Shelf-Life) - An individual item of supply which is determined through an evaluation of technical test data and/or actual experience to be an item with a definite non-extendible period of shelf-life OR An individual item of supply having an assigned shelf-life time period that may be extended after completion of inspection/test/restorative action.
ARMY: This is a nonreparable item. If condemned or economically unserviceable, then dispose at the level authorized replace the item; MARINE CORPS: Nonreparable item. When unserviceable, condemn and dispose at the level indicated by the first digit of the maintenance code; NAVY: Special Program Consumables
Department of the Air Force
U.S. Marine Corps
Department of the Navy
Defense Logistics Agency
U.S. Coast Guard
MRC | Decoded Requirement | Clear Text Reply |
---|---|---|
AFRV | Connector Locking Method | INTERNALLY THREADED COUPLING RING |
AFRW | Connector Cable Strain Relief Method | CRIMP TYPE |
CSGF | Contact Material Document And Classification | QQ-B-626 FED SPEC SINGLE MATERIAL RESPONSE SINGLE MATING END SINGLE CONTACT GROUPING |
CQTZ | Contact Material | COPPER ALLOY SINGLE MATING END SINGLE CONTACT GROUPING |
AFRD | Contact Maximum Ac Voltage Rating In Volts | 500.0 SINGLE MATING END SINGLE CONTACT GROUPING |
AFQX | Contact Position Arrangement Style | NONSTD SINGLE MATING END |
AFQZ | Contact Removability | REMOVABLE SINGLE MATING END SINGLE CONTACT GROUPING |
AFRF | Contact Maximum Frequency Rating | 5000.0 MEGAHERTZ SINGLE MATING END SINGLE CONTACT GROUPING |
CRBJ | Contact Surface Treatment Document And Classification | MIL-G-45204 MIL SPEC SINGLE TREATMENT RESPONSE SINGLE MATING END SINGLE CONTACT GROUPING |
CQYH | Contact Surface Treatment | SILVER SINGLE MATING END SINGLE CONTACT GROUPING |
ADZC | Environmental Protection | MOISTURE RESISTANT AND VIBRATION RESISTANT AND SALT WATER RESISTANT |
AAQL | Body Style | STRAIGHT SHAPE, INTERNAL COUPLING |
AFQW | Mating End Quantity | 1 |
CQJX | Nominal Thread Size | 0.625 INCHES |
ADAV | Overall Diameter | 0.750 INCHES MAXIMUM |
CXCG | Included Contact Quantity | 1 SINGLE MATING END SINGLE CONTACT GROUPING |
CXCL | Included Contact Type | COAXIAL PIN SINGLE MATING END SINGLE CONTACT GROUPING |
CQZG | Insert Material | PLASTIC SINGLE MATING END |
PMLC | Precious Material And Location | CONTACT AND BODY SURFACE GOLD |
PRMT | Precious Material | GOLD |
CTHH | Shell Material Document And Classification | QQ-B-626 FED SPEC SINGLE MATERIAL RESPONSE |
CTBC | Shell Surface Treatment Document And Classification | QQ-S-365 FED SPEC SINGLE TREATMENT RESPONSE |
CSPT | Shell Material | COPPER ALLOY |
CSWM | Shell Surface Treatment | SILVER |
AFRT | Shell Type | SOLID |
ABHP | Overall Length | 1.828 INCHES NOMINAL |
CQTM | Terminal Location | BACK SINGLE MATING END SINGLE CONTACT GROUPING |
CSCF | Terminal Type | CRIMP SINGLE MATING END SINGLE CONTACT GROUPING |
AAJD | Thread Class | 2A |
AAJF | Thread Direction | RIGHT-HAND |
THSD | Thread Series Designator | UNEF |
AFQR | Threaded Device Type | COUPLING FACILITY |