Manufacturer Part Number | RNCC | RNVC | Manufacturer Name | CAGE | |
---|---|---|---|---|---|
MS3102R-12S-3S | 3 - Design Control Reference | 1 - Incomplete Part Number | AMPHENOL CORPORATION | 77820 | ![]() |
L00309 | 3 - Design Control Reference | 2 - Production Item | DLA LAND AND MARITIME | 16236 | ![]() |
Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.
A design control or other reference number that does NOT identify an item of production without the use of additional information, or a specific part, type, or similar reference number does NOT identify or item of supply without the use of additional information.
A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.
FSG | FSC | NIIN | FIIG | INC | CRITICALITY | TYPE OF ITEM | MRC | DEMIL | HMIC | EDC | PMIC | ADPEC | DATE CREATED |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
59 | 5935 | 001699395 | A039B0 | 15093 | Y | 1 | A | P | A | G | 25 Aug 1972 |
The item does not have a nuclear hardened feature but does have other critical feature(s) such as tolerance, fit restriction or application.
Full Descriptive Item Identification
Non-MLI/ Non-SLI — Demilitarization not required.
Indicates there is no information in the HMIRS; however, the NSN is in a FSC in Table II of Federal Standard 313 and a MSDS may be required by the user. The requirement for a MSDS is dependent on a hazard determination of the supplier or the intended end use of the product.
No known Electrostatic Discharge (ESD) or Electromagnetic Interference (EMI) sensitivity.
Item contains gold.
MOE Rule | Former MOE | AMC | AMSC | NIMSC | IMC | IMC Activity | AAC | DSOR | Collaborators | Receivers | Effective Date | |||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
YB01 | 1 Apr 1991 | |||||||||||||||||||||||||||||
ZG01 | 1 Oct 1994 | |||||||||||||||||||||||||||||
DGX1 | 3 | C | 15 Jun 2012 |
Acquire directly from the actual manufacturer, whether or not the prime contractor is the actual manufacturer.
This part requires engineering source approval by the design control activity in order to maintain the quality of the part. An alternate source must qualify in accordance with the design control activity's procedures, as approved by the cognizant Government engineering activity. Valid AMCs: 1, 2, 3, 4 and 5.
RNFC | RNCC | RNVC | DAC | RNAAC | RNSC | RNJC | SADC | MSDS | HCC | Reference Number | CAGE | |
---|---|---|---|---|---|---|---|---|---|---|---|---|
3 | 1 | 5 | ZZ | MS3102R-12S-3S | 77820 | ![]() | ||||||
3 | 2 | 1 | TX | D | L00309 | 16236 | ![]() |
Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.
A design control or other reference number that does NOT identify an item of production without the use of additional information, or a specific part, type, or similar reference number does NOT identify or item of supply without the use of additional information.
The reference number is represented by a drawing, but the drawing was not available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number.
USA
A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.
The reference number is represented by a drawing and the drawing was available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number. The RNAAC will furnish the drawing upon request.
Defense Supply Center Columbus, Columbus, OH 43218
Procurement authority of the manufacturer and reference number have not yet been checked. NOTE: This code is to be allocated to reference numbers still requiring checks on procurement authority.
ISC | Originator | NIIN Status | Replaced / Replacement ISC | Replaced / Replacement Originator | Replacement NIIN Status | Replacement Date | Replaced / Replacement NSN | Decision Date |
---|---|---|---|---|---|---|---|---|
3 | TX | 0 | B | TX | 0 | 26 Nov 1983 | 5935011370883 | 18 Jun 1998 |
An item which, as a result of a formal item reduction study, is accepted as not authorized for procurement.
Defense Supply Center Columbus, Columbus, OH 43218
Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.
A new item authorized for procurement, contained in a new or revised superseding specification or standard, that replaces prior items.
Integrity | Originating | HMC | LCL | WCC | TCC | SHC | ADC | ACC | ASH | LTL | NMFC | NMFC Sub Item | UFC | Freight Description | Rail Variance |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
TX | 658 | Z | 9 | A | H | Z | W | 061680 | Z | 34570 | ELEC-WIRING-PLUGS-ETC |
Defense Supply Center Columbus, Columbus, OH 43218
Electical Appliances, Small
No special type of cargo code applicable
No special handling required
Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
No special handling required.
Variable Rating
No Variation. NMFC and UFCC Match.
Defense Logistics Agency, Enterprise Business Systems
TERMINAL ITEM (NON-STOCKED ITEMS) Future procurement is not authorized. No wholesale stock is available for issue. 1. Requisitions will not be processed to the wholesale manager. 2. Internal Service/agency requisitioning may be continued in accordance with the Service/agency requisitioning policies.
Unclassified
No QUP
ARMY: Item requires special handling or condemnation procedures for specific reasons, such as precious metal content, high dollar value, critical material, or hazardous materiel. Refer to appropriate manuals or directives for specific instructions. MARINE CORPS: Item requires special handling/or condemnation procedures because of specific reasons (i.e., precious metal content, high dollar value, critical material, or hazardous material). Refer to appropriate manuals/directives for specific instructions. NAVY: Field Activity Control Items
Each - A numeric quantity of one item of supply. Do not use if a more specific term applies, such as kit, set, assortment, assembly, group, sheet, plate, strip or length.
TYPE I or TYPE II (Non-Deteriorative/No Shelf-Life) - An individual item of supply which is determined through an evaluation of technical test data and/or actual experience to be an item with a definite non-extendible period of shelf-life OR An individual item of supply having an assigned shelf-life time period that may be extended after completion of inspection/test/restorative action.
1
Department of the Army
Department of the Navy
Defense Logistics Agency
MRC | Decoded Requirement | Clear Text Reply |
---|---|---|
AFQK | Distance From Mounting Shoulder To Front Face | 0.562 INCHES MINIMUM AND 0.593 INCHES MAXIMUM |
AEBW | Center To Center Distance Between Mounting Facilities Parallel To Height | 0.807 INCHES MINIMUM AND 0.817 INCHES MAXIMUM |
AFRV | Connector Locking Method | EXTERNALLY THREADED SHELL |
AFRD | Contact Maximum Ac Voltage Rating In Volts | 500.0 SINGLE MATING END SINGLE CONTACT GROUPING |
AFRC | Contact Maximum Current Rating In Amps | 22.0 SINGLE MATING END SINGLE CONTACT GROUPING |
AFQZ | Contact Removability | NONREMOVABLE SINGLE MATING END SINGLE CONTACT GROUPING |
AFRE | Contact Maximum Dc Voltage Rating In Volts | 700.0 SINGLE MATING END SINGLE CONTACT GROUPING |
AFQX | Contact Position Arrangement Style | 12S-3 SINGLE MATING END |
CQYH | Contact Surface Treatment | GOLD SINGLE MATING END SINGLE CONTACT GROUPING AND SILVER SINGLE MATING END SINGLE CONTACT GROUPING |
CRTL | Criticality Code Justification | FEAT |
AEHA | Distance Between Centerlines Of Mounting Facilities Parallel To Body Width | 0.807 INCHES MINIMUM AND 0.817 INCHES MAXIMUM |
ADZC | Environmental Protection | MOISTURE RESISTANT AND SALT WATER RESISTANT AND VIBRATION RESISTANT |
AAQL | Body Style | STRAIGHT SHAPE, EXTERNAL COUPLING |
AFQW | Mating End Quantity | 1 |
AKMG | Nominal Thread Length | 0.375 INCHES |
CQJX | Nominal Thread Size | 0.750 INCHES |
CXCG | Included Contact Quantity | 2 SINGLE MATING END SINGLE CONTACT GROUPING |
CXCL | Included Contact Type | ROUND SOCKET SINGLE MATING END SINGLE CONTACT GROUPING |
AFRP | Insert Position In Deg | 0.0 |
AFRN | Polarization Method | KEYWAY OR MULTIPLE KEYWAY |
PMLC | Precious Material And Location | CONTACT SURFACES GOLD AND CONTACT SURFACES SILVER |
PMWT | Precious Material And Weight | 0.002 GOLD GRAINS, TROY AND 0.002 SILVER GRAINS, TROY |
PRMT | Precious Material | GOLD AND SILVER |
CSPT | Shell Material | ALUMINUM ALLOY |
CSWM | Shell Surface Treatment | CADMIUM |
AFRT | Shell Type | SOLID |
ABKW | Overall Height | 1.063 INCHES MINIMUM AND 1.125 INCHES MAXIMUM |
ABHP | Overall Length | 1.188 INCHES MAXIMUM |
ABMK | Overall Width | 1.063 INCHES MINIMUM AND 1.125 INCHES MAXIMUM |
FEAT | Special Features | ITEM MUST COMPLY WITH REQUIREMENTS OF DEFENSE ELECTRONICS SUPPLY CENTER PRODUCTION STANDARD NO. L00309 |
AEBV | Unthreaded Mounting Hole Diameter | 0.115 INCHES MINIMUM AND 0.130 INCHES MAXIMUM |
CQTM | Terminal Location | BACK SINGLE MATING END SINGLE CONTACT GROUPING |
CSCF | Terminal Type | SOLDER WELL SINGLE MATING END SINGLE CONTACT GROUPING |
AAJD | Thread Class | 2A |
AAJF | Thread Direction | RIGHT-HAND |
CMLP | Thread Quantity Per Inch | 20 |
THSD | Thread Series Designator | UNEF |
AFQR | Threaded Device Type | COUPLING FACILITY |