5935-00-241-0383

CONNECTOR,PLUG,ELECTRICAL


5935-00-241-0383 (5935002410383, 002410383)
Part Number (1 listing): 49X649
Summary

FSG 59 / FSC 5935

DEMIL: A

DEMIL INT:

HMIC: P

Date Created: 1 Jan 1961

Replacement NSN:

5935-01-062-8659

Replacement Date: 2 May 1983

Request a Quote


;



MASTER CROSS REFERENCE LIST (MCRL) | NSN 5935-00-241-0383 Submit RFQ
Manufacturer Part NumberRNCCRNVCManufacturer NameCAGE
49X6493 - Design Control Reference2 - Production ItemGENERAL ELECTRIC CO  73773      
49X6493 - Design Control Reference2 - Production ItemGENERAL ELECTRIC CO  24446    CAGE 24446  
Code Definitions

3 - Design Control Reference

Reference Number Category Code (DRN_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

2 - Production Item

Reference Number Variation Code (DRN_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.


FLIS - SEG A - IDENTIFICATION | NSN 5935-00-241-0383 Submit RFQ
FSGFSCNIINFIIGINCCRITICALITYTYPE OF ITEMMRCDEMILHMICEDCPMICADPECDATE CREATED
595935002410383A039B001938X49APU1 Jan 1961
Code Definitions

59

Federal Supply Group (FSG_3994/FSC_WI_FSG_3996)


Electrical and Electronic Equipment Components

5935

Federal Supply Class (FSC_3994/FSC_WI_FSC_3996)


Connectors, Electrical

002410383

National Item Identification Number (NCB_CD_4130/I_I_NBR_4131)


NSN 5935-00-241-0383

A039B0

Federal Item Identification Guide (FIIG_4065)

01938

Item Naming Code (INC_4080)

1 Jan 1961

NIIN Assignment Date (DT_NIIN_ASGMT_2180)

X

Item Criticality (CRITL_CD_FIIG_3843)


The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.

4

Type of Item Identification (TYP_II_4820)


Partial Descriptive Item Identification (Type 1 Concept)

9

Reference / Partial Descriptive Method Reason Code (RPDMRC_4765)


A Defense Logistics Information Service-generated code for items lacking but requiring an RPDMRC (i.e., through mass FIIG revision change an item may be downgraded from a type 1 to a reference or partial descriptive method item identification).

A

Demilitarization Code (DEMIL_CD_0167)


Non-MLI/ Non-SLI — Demilitarization not required.

P

Hazardous Material Indicator Code (HMIC_0865)


Indicates there is no information in the HMIRS; however, the NSN is in a FSC in Table II of Federal Standard 313 and a MSDS may be required by the user. The requirement for a MSDS is dependent on a hazard determination of the supplier or the intended end use of the product.

U

Precious Metals Indicator Code (PMIC_0802)


Precious Metal Content is unknown.


FLIS - SEG B - MOE RULE DATA | NSN 5935-00-241-0383 Submit RFQ
MOE RuleFormer MOEAMCAMSCNIMSCIMCIMC ActivityAACDSORCollaboratorsReceiversEffective Date
G90000L1 Apr 1991
Code Definitions

0

Acquisition Method Code (AMC_2871)


Not Established

L

Acquisition Advice Code (AAC_2507)


LOCAL PURCHASE (NON-STOCKED ITEMS) Defense Logistics Agency (DLA)/GSA/Service/Agency-managed items authorized for local purchase as normal means of support at base, post, camp or station level. Item not stocked in wholesale distribution system of IMM/Service/Agency ICP.


FLIS - SEG E - ITEM STANDARDIZATION DATA | NSN 5935-00-241-0383 Submit RFQ
ISCOriginatorNIIN StatusReplaced / Replacement ISCReplaced / Replacement OriginatorReplacement NIIN StatusReplacement DateReplaced / Replacement NSNDecision Date
3TX0BTX02 May 1983 5935010628659 7 Oct 1966
Code Definitions

3

Item Standardization Code (ISC_2650)


An item which, as a result of a formal item reduction study, is accepted as not authorized for procurement.

TX

Originator of Standardization Decision (ORG_STDZN_DEC_9325)


Defense Supply Center Columbus, Columbus, OH 43218

0

NIIN Status Code (NIIN_STAT_CD_2670)


Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.

B

Replaced / Replacement Item Standardization Code (ISC_2650)


A new item authorized for procurement, contained in a new or revised superseding specification or standard, that replaces prior items.

2 May 1983

Date of Replacement Standardization Decision (DT_STDZN_DEC_2300)

5935-01-062-8659

Replaced / Replacement NSN (RP_NSN_STD_RL_8977 / RPLM_NSN_STDZ_9525)

7 Oct 1966

Standardization Decision Date (DT_STDZN_DEC_2300)


FLIS - SEG G - FREIGHT DATA | NSN 5935-00-241-0383 Submit RFQ
IntegrityOriginatingHMCLCLWCCTCCSHCADCACCASHLTLNMFCNMFC Sub ItemUFCFreight DescriptionRail Variance
Code Definitions

XX

Originating Activity Code (ORIG_ACTY_CD_4210)


Rail Variance

Rail Variance (RAIL_VARI_CD_4760)


No Variation. NMFC and UFCC Match.


FLIS - SEG M/V - CHARACTERISTICS DATA | NSN 5935-00-241-0383 Submit RFQ
MRCDecoded RequirementClear Text Reply
ABHPOverall Length0.906 INCHES NOMINAL
ADAVOverall Diameter1.781 INCHES NOMINAL
AFRWConnector Cable Strain Relief MethodCABLE CLAMP
AFQJCable Entrance Diameter0.750 INCHES NOMINAL
CSPTShell MaterialSTEEL
AFQWMating End Quantity1
AFQXContact Position Arrangement StyleFK-V3 SINGLE MATING END
CQZGInsert MaterialPLASTIC SINGLE MATING END
CXCGIncluded Contact Quantity2 SINGLE MATING END SINGLE CONTACT GROUPING
CXCLIncluded Contact TypeFLAT SOCKET SINGLE MATING END SINGLE CONTACT GROUPING
AFRCContact Maximum Current Rating In Amps20.0 SINGLE MATING END SINGLE CONTACT GROUPING
AFRDContact Maximum Ac Voltage Rating In Volts250.0 SINGLE MATING END SINGLE CONTACT GROUPING
AFREContact Maximum Dc Voltage Rating In Volts250.0 SINGLE MATING END SINGLE CONTACT GROUPING


Back to Top
Back to Top