5935-00-259-0052

CONNECTOR,PLUG,ELECTRICAL


5935-00-259-0052 (5935002590052, 002590052)
Part Number (1 listing): MS3106A20-18S
Summary

FSG 59 / FSC 5935

DEMIL: A

DEMIL INT:

HMIC: P

Date Created: 1 Jan 1963

Replacement NSN:

5935-01-005-2328

Replacement Date: 10 Jun 1985

Request a Quote


;



MASTER CROSS REFERENCE LIST (MCRL) | NSN 5935-00-259-0052 Submit RFQ
Manufacturer Part NumberRNCCRNVCManufacturer NameCAGE
MS3106A20-18S2 - Definitive Specification or Standard Document2 - Production ItemMILITARY STANDARDS  96906    CAGE 96906  
Code Definitions

2 - Definitive Specification or Standard Document

Reference Number Category Code (DRN_2910)


Definitive Government Specification or Standard Designator Reference. A part number, style number, or type designator included in or developed in accordance with a Government specification or standard which has the effect of fully identifying an item of supply. This code shall also be used for a Government specification or standard which, although not including part numbers, style numbers, or type designators, covers a single item of upply. These reference numbers may be coded with Reference Number Variation Code (RNVC) 1 in accordance with volume 2, paragraph 2.9.2.n.(4).

2 - Production Item

Reference Number Variation Code (DRN_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.


FLIS - SEG A - IDENTIFICATION | NSN 5935-00-259-0052 Submit RFQ
FSGFSCNIINFIIGINCCRITICALITYTYPE OF ITEMMRCDEMILHMICEDCPMICADPECDATE CREATED
595935002590052A039B001938X1APU1 Jan 1963
Code Definitions

59

Federal Supply Group (FSG_3994/FSC_WI_FSG_3996)


Electrical and Electronic Equipment Components

5935

Federal Supply Class (FSC_3994/FSC_WI_FSC_3996)


Connectors, Electrical

002590052

National Item Identification Number (NCB_CD_4130/I_I_NBR_4131)


NSN 5935-00-259-0052

A039B0

Federal Item Identification Guide (FIIG_4065)

01938

Item Naming Code (INC_4080)

1 Jan 1963

NIIN Assignment Date (DT_NIIN_ASGMT_2180)

X

Item Criticality (CRITL_CD_FIIG_3843)


The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.

1

Type of Item Identification (TYP_II_4820)


Full Descriptive Item Identification

A

Demilitarization Code (DEMIL_CD_0167)


Non-MLI/ Non-SLI — Demilitarization not required.

P

Hazardous Material Indicator Code (HMIC_0865)


Indicates there is no information in the HMIRS; however, the NSN is in a FSC in Table II of Federal Standard 313 and a MSDS may be required by the user. The requirement for a MSDS is dependent on a hazard determination of the supplier or the intended end use of the product.

U

Precious Metals Indicator Code (PMIC_0802)


Precious Metal Content is unknown.


FLIS - SEG B - MOE RULE DATA | NSN 5935-00-259-0052 Submit RFQ
MOE RuleFormer MOEAMCAMSCNIMSCIMCIMC ActivityAACDSORCollaboratorsReceiversEffective Date
ZR011 Apr 1991
Code Definitions

FLIS - SEG E - ITEM STANDARDIZATION DATA | NSN 5935-00-259-0052 Submit RFQ
ISCOriginatorNIIN StatusReplaced / Replacement ISCReplaced / Replacement OriginatorReplacement NIIN StatusReplacement DateReplaced / Replacement NSNDecision Date
3TX1BTX010 Jun 1985 5935010052328 8 Oct 1965
Code Definitions

3

Item Standardization Code (ISC_2650)


An item which, as a result of a formal item reduction study, is accepted as not authorized for procurement.

TX

Originator of Standardization Decision (ORG_STDZN_DEC_9325)


Defense Supply Center Columbus, Columbus, OH 43218

1

NIIN Status Code (NIIN_STAT_CD_2670)


Represents an item for which a U.S. activity proposed cancelled-invalid or cancelled-use action or that the NIIN Status Code be changed to 9, and one or more NATO/FC did not concur in the proposal. See volume 4, chapter 4.9.Item is restricted to North Atlantic Treaty Organization/foreign country (NATO/FC) use only.Represents an item for which a U.S. activity proposed cancelled-invalid or cancelled-use action or that the NIIN Status Code be changed to 9, and one or more NATO/FC did not concur in the proposal. Item is restricted to North Atlantic Treaty Organization/foreign country (NATO/FC) use only.

B

Replaced / Replacement Item Standardization Code (ISC_2650)


A new item authorized for procurement, contained in a new or revised superseding specification or standard, that replaces prior items.

0

Replaced / Replacement NIIN Status Code (NIIN_STAT_CD_2670)


Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.

10 Jun 1985

Date of Replacement Standardization Decision (DT_STDZN_DEC_2300)

5935-01-005-2328

Replaced / Replacement NSN (RP_NSN_STD_RL_8977 / RPLM_NSN_STDZ_9525)

8 Oct 1965

Standardization Decision Date (DT_STDZN_DEC_2300)


FLIS - SEG G - FREIGHT DATA | NSN 5935-00-259-0052 Submit RFQ
IntegrityOriginatingHMCLCLWCCTCCSHCADCACCASHLTLNMFCNMFC Sub ItemUFCFreight DescriptionRail Variance
P658Z5AHZW061680Z34570ELEC-WIRING-PLUGS-ETC1
Code Definitions

XX

Originating Activity Code (ORIG_ACTY_CD_4210)


P

Less Than Carload (LCL_CD_2760)


77.5

658

Water Commodity Code (WRT_CMDTY_CD_9275)


Electical Appliances, Small

Z

Type Cargo Code (TYPE_CGO_CD_9260)


No special type of cargo code applicable

5

Special Handling Code (SP_HDLG_CD_9240)


Protected (Pilferable)

A

Air Dimension Code (AIR_DIM_CD_9220)


Shipment is not a consolidation and does not exceed 72 inches in any dimension.

H

Air Commodity Code (AIR_CMTY_HDLG_9215)


Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.

Z

Air Special Handling Code (AIR_CMTY_HDLG_9215)


No special handling required.

W

Less Than Truckload (CLAS_RTNG_CD_2770)


Variable Rating

061680

National Motor Freight Classification Number (NMFC Item Number) (NMFC_2850)

Z

NMFC Sub Item Number (SUB_ITM_NBR_0861)

34570

Uniform Freight Classification (UFC_CD_MODF_3040)

ELEC-WIRING-PLUGS-ETC

Freight Description (FRT_DESC_4020)

1 Rail Variance

Rail Variance (RAIL_VARI_CD_4760)


A Variation Exists. NMFC and UFCC Do Not Match. Activity needs to determine which of these descriptions apply.


FLIS - SEG M/V - CHARACTERISTICS DATA | NSN 5935-00-259-0052 Submit RFQ
MRCDecoded RequirementClear Text Reply
AFRVConnector Locking MethodINTERNALLY THREADED COUPLING RING
AFRWConnector Cable Strain Relief MethodCONDUIT NUT
AFRDContact Maximum Ac Voltage Rating In Volts500.0 SINGLE MATING END ALL CONTACT GROUPINGS
AFRCContact Maximum Current Rating In Amps22.0 SINGLE MATING END 2ND CONTACT GROUPING
AFRCContact Maximum Current Rating In Amps41.0 SINGLE MATING END 1ST CONTACT GROUPING
AFQZContact RemovabilityNONREMOVABLE SINGLE MATING END 2ND CONTACT GROUPING
AFQZContact RemovabilityREMOVABLE SINGLE MATING END 1ST CONTACT GROUPING
AFREContact Maximum Dc Voltage Rating In Volts700.0 SINGLE MATING END ALL CONTACT GROUPINGS
AFQXContact Position Arrangement Style20-18 SINGLE MATING END
AAQLBody StyleSTRAIGHT SHAPE, INTERNAL COUPLING W/BACKSHELL
AFQWMating End Quantity1
CQJXNominal Thread Size1.188 INCHES AND 1.250 INCHES
CXCLIncluded Contact TypeROUND SOCKET SINGLE MATING END ALL CONTACT GROUPINGS
CXCGIncluded Contact Quantity3 SINGLE MATING END 1ST CONTACT GROUPING
CXCGIncluded Contact Quantity6 SINGLE MATING END 2ND CONTACT GROUPING
AFRPInsert Position In Deg0.0
AFRNPolarization MethodKEYWAY OR MULTIPLE KEYWAY
AFRTShell TypeSOLID
CSPTShell MaterialALUMINUM ALLOY
ADAVOverall Diameter1.469 INCHES MAXIMUM
ABHPOverall Length2.188 INCHES MAXIMUM
CQTMTerminal LocationBACK SINGLE MATING END ALL CONTACT GROUPINGS
CSCFTerminal TypeSOLDER WELL SINGLE MATING END ALL CONTACT GROUPINGS
AAJDThread Class2A AND 2B
AAJFThread DirectionRIGHT-HAND
THSDThread Series DesignatorUNEF AND UNEF
AFQRThreaded Device TypeBACK SHELL AND COUPLING FACILITY