5935-00-325-5106

CONNECTOR,PLUG,ELECTRICAL


5935-00-325-5106 (5935003255106, 003255106)
Part Numbers (6 listings): 534808-72 | WTAV66PD9JL | FA0111-68 | 3479951-1 | FA0111-66 | 8819200007-2 |
Summary

FSG 59 / FSC 5935

DEMIL: A

DEMIL INT: 1

HMIC: P

Date Created: 3 Dec 1973

Unit Weight: 0.3 lbs

Unit Size: None

Unit Pack Cube: None

Replacement NSN:

5935-01-106-4935

Replacement Date: 25 Oct 1987

MSDS: None

Hazmat: None

Request a Quote


;



MASTER CROSS REFERENCE LIST (MCRL) | NSN 5935-00-325-5106 Submit RFQ
Manufacturer Part NumberRNCCRNVCManufacturer NameCAGE
534808-723 - Design Control Reference2 - Production ItemRAYTHEON COMPANY  96214    CAGE 96214  
WTAV66PD9JL3 - Design Control Reference2 - Production ItemAIRBORN INTERCONNECT, INC.  10400    CAGE 10400  
FA0111-685 - Replaced / Discontinued2 - Production ItemTEXAS INSTRUMENTS INC  73803      
3479951-15 - Replaced / Discontinued2 - Production ItemRAYTHEON COMPANY  82577    CAGE 82577  
FA0111-665 - Replaced / Discontinued2 - Production ItemINCON, INC.  59350      
8819200007-25 - Replaced / Discontinued2 - Production ItemNAVCOM DEFENSE ELECTRONICS, INC.  57057    CAGE 57057  
Code Definitions

3 - Design Control Reference

Reference Number Category Code (DRN_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

5 - Replaced / Discontinued

Reference Number Category Code (DRN_2910)


Secondary Reference. Any additional number, other than a primary number (codes 1,2,3,4) informative reference (code 6) or vendor item drawing reference (code 7) assigned to an item of production or supply by a commercial or Government organization, which represents the same item of production or supply to which the National Stock Number (NSN) was assigned. The reference number may have had an RNCC of 1, 2, 3, 4 or 7 but has since been replaced in the item-of-supply concept of the NSN by another primary number.

2 - Production Item

Reference Number Variation Code (DRN_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.


FLIS - SEG A - IDENTIFICATION | NSN 5935-00-325-5106 Submit RFQ
FSGFSCNIINFIIGINCCRITICALITYTYPE OF ITEMMRCDEMILHMICEDCPMICADPECDATE CREATED
595935003255106A039B001938X1APG3 Dec 1973
Code Definitions

59

Federal Supply Group (FSG_3994/FSC_WI_FSG_3996)


Electrical and Electronic Equipment Components

5935

Federal Supply Class (FSC_3994/FSC_WI_FSC_3996)


Connectors, Electrical

003255106

National Item Identification Number (NCB_CD_4130/I_I_NBR_4131)


NSN 5935-00-325-5106

A039B0

Federal Item Identification Guide (FIIG_4065)

01938

Item Naming Code (INC_4080)

3 Dec 1973

NIIN Assignment Date (DT_NIIN_ASGMT_2180)

X

Item Criticality (CRITL_CD_FIIG_3843)


The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.

1

Type of Item Identification (TYP_II_4820)


Full Descriptive Item Identification

A

Demilitarization Code (DEMIL_CD_0167)


Non-MLI/ Non-SLI — Demilitarization not required.

P

Hazardous Material Indicator Code (HMIC_0865)


Indicates there is no information in the HMIRS; however, the NSN is in a FSC in Table II of Federal Standard 313 and a MSDS may be required by the user. The requirement for a MSDS is dependent on a hazard determination of the supplier or the intended end use of the product.

G

Precious Metals Indicator Code (PMIC_0802)


Item contains gold.


FLIS - SEG B - MOE RULE DATA | NSN 5935-00-325-5106 Submit RFQ
MOE RuleFormer MOEAMCAMSCNIMSCIMCIMC ActivityAACDSORCollaboratorsReceiversEffective Date
YB011 Apr 1991
ZK011 Apr 1991
ZR011 Apr 1991
Code Definitions

FLIS - SEG C - REFERENCE NUMBER | NSN 5935-00-325-5106 Submit RFQ
RNFCRNCCRNVCDACRNAACRNSCRNJCSADCMSDSHCCReference NumberCAGE
3323TXDWTAV66PD9JL  10400   CAGE/10400
43229ZD534808-72  96214   CAGE/96214
525TX8819200007-2  57057   CAGE/57057
525TXFA0111-66  59350  
45259ZDFA0111-68  73803  
525TX3479951-1  82577   CAGE/82577
Code Definitions

3

Reference Number Format Code (RNFC_2920)


Number format is unknown. (Coded RNFC 3 by the Defense Logistics Information Service upon implementation of FLIS.)

3

Reference Number Category Code (RNCC_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

2

Reference Number Variation Code (RNVC_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.

3

Document Availability Code (DAC_2640)


The reference number is represented by technical documentation other than a drawing and the documentation was available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number. The RNAAC will furnish the technical documentation upon request.

TX

Reference Number Action Activity Code (RNAAC_2900)


Defense Supply Center Columbus, Columbus, OH 43218

D

Reference Number Status Code (RNSC_2923)


Procurement authority of the manufacturer and reference number have not yet been checked. NOTE: This code is to be allocated to reference numbers still requiring checks on procurement authority.

4

Reference Number Format Code (RNFC_2920)


Number is totally in-the-clear (without modification) as originally configured by the manufacturer, design control activity, or supplier.

2

Document Availability Code (DAC_2640)


The reference number is represented by a drawing and the drawing was available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number; however, the RNAAC cannot furnish the drawing.

9Z

Reference Number Action Activity Code (RNAAC_2900)


DLIS-K, Battle Creek, MI 49037-3084

5

Reference Number Category Code (RNCC_2910)


Secondary Reference. Any additional number, other than a primary number (codes 1,2,3,4) informative reference (code 6) or vendor item drawing reference (code 7) assigned to an item of production or supply by a commercial or Government organization, which represents the same item of production or supply to which the National Stock Number (NSN) was assigned. The reference number may have had an RNCC of 1, 2, 3, 4 or 7 but has since been replaced in the item-of-supply concept of the NSN by another primary number.

5

Document Availability Code (DAC_2640)


The reference number is represented by a drawing, but the drawing was not available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number.


FLIS - SEG E - ITEM STANDARDIZATION DATA | NSN 5935-00-325-5106 Submit RFQ
ISCOriginatorNIIN StatusReplaced / Replacement ISCReplaced / Replacement OriginatorReplacement NIIN StatusReplacement DateReplaced / Replacement NSNDecision Date
3TX11TX025 Oct 1987 5935011064935 21 Oct 1987
Code Definitions

3

Item Standardization Code (ISC_2650)


An item which, as a result of a formal item reduction study, is accepted as not authorized for procurement.

TX

Originator of Standardization Decision (ORG_STDZN_DEC_9325)


Defense Supply Center Columbus, Columbus, OH 43218

1

NIIN Status Code (NIIN_STAT_CD_2670)


Represents an item for which a U.S. activity proposed cancelled-invalid or cancelled-use action or that the NIIN Status Code be changed to 9, and one or more NATO/FC did not concur in the proposal. See volume 4, chapter 4.9.Item is restricted to North Atlantic Treaty Organization/foreign country (NATO/FC) use only.Represents an item for which a U.S. activity proposed cancelled-invalid or cancelled-use action or that the NIIN Status Code be changed to 9, and one or more NATO/FC did not concur in the proposal. Item is restricted to North Atlantic Treaty Organization/foreign country (NATO/FC) use only.

1

Replaced / Replacement Item Standardization Code (ISC_2650)


An item authorized for procurement as a result of a formal item reduction study and accepted as a replacement for one or more items not authorized for procurement. In addition, in generic relationships, a code 1 item is related to a code 2 item.

0

Replaced / Replacement NIIN Status Code (NIIN_STAT_CD_2670)


Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.

25 Oct 1987

Date of Replacement Standardization Decision (DT_STDZN_DEC_2300)

5935-01-106-4935

Replaced / Replacement NSN (RP_NSN_STD_RL_8977 / RPLM_NSN_STDZ_9525)

21 Oct 1987

Standardization Decision Date (DT_STDZN_DEC_2300)


FLIS - SEG G - FREIGHT DATA | NSN 5935-00-325-5106 Submit RFQ
IntegrityOriginatingHMCLCLWCCTCCSHCADCACCASHLTLNMFCNMFC Sub ItemUFCFreight DescriptionRail Variance
TX658Z9AHZW061680Z34570ELEC-WIRING-PLUGS-ETC
Code Definitions

TX

Originating Activity Code (ORIG_ACTY_CD_4210)


Defense Supply Center Columbus, Columbus, OH 43218

658

Water Commodity Code (WRT_CMDTY_CD_9275)


Electical Appliances, Small

Z

Type Cargo Code (TYPE_CGO_CD_9260)


No special type of cargo code applicable

9

Special Handling Code (SP_HDLG_CD_9240)


No special handling required

A

Air Dimension Code (AIR_DIM_CD_9220)


Shipment is not a consolidation and does not exceed 72 inches in any dimension.

H

Air Commodity Code (AIR_CMTY_HDLG_9215)


Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.

Z

Air Special Handling Code (AIR_CMTY_HDLG_9215)


No special handling required.

W

Less Than Truckload (CLAS_RTNG_CD_2770)


Variable Rating

061680

National Motor Freight Classification Number (NMFC Item Number) (NMFC_2850)

Z

NMFC Sub Item Number (SUB_ITM_NBR_0861)

34570

Uniform Freight Classification (UFC_CD_MODF_3040)

ELEC-WIRING-PLUGS-ETC

Freight Description (FRT_DESC_4020)

Rail Variance

Rail Variance (RAIL_VARI_CD_4760)


No Variation. NMFC and UFCC Match.


FLIS - SEG H - MANAGEMENT DATA | NSN 5935-00-325-5106 Submit RFQ
Unit PriceMOESOSAACCIICQUPReparabilityUISLC
DNSMSYU0EA0
DSSMSYU0EA0
Code Definitions

SMS

Source of Supply (SOS_CD_3690) or Source of Supply Modifier (SOSM_CD_2948)


Defense Logistics Agency, Enterprise Business Systems

Y

Acquisition Advice Code (AAC_2507)


TERMINAL ITEM (NON-STOCKED ITEMS) Future procurement is not authorized. No wholesale stock is available for issue. 1. Requisitions will not be processed to the wholesale manager. 2. Internal Service/agency requisitioning may be continued in accordance with the Service/agency requisitioning policies.

U

Controlled Item Inventory Code (CIIC_2863)


Unclassified

0

Quantity Unit Pack (QUP_6106)


No QUP

EA

Unit of Issue (UI_3050)


Each - A numeric quantity of one item of supply. Do not use if a more specific term applies, such as kit, set, assortment, assembly, group, sheet, plate, strip or length.

0

Shelf Life Code (SLC_2943)


TYPE I or TYPE II (Non-Deteriorative/No Shelf-Life) - An individual item of supply which is determined through an evaluation of technical test data and/or actual experience to be an item with a definite non-extendible period of shelf-life OR An individual item of supply having an assigned shelf-life time period that may be extended after completion of inspection/test/restorative action.

DN

Service / Agency Code (MOE_CD_2833)


Department of the Navy

DS

Service / Agency Code (MOE_CD_2833)


Defense Logistics Agency


FLIS - SEG W - PACKAGING DATA | NSN 5935-00-325-5106 Submit RFQ
SourcePICA / SICAPackaging CategoryStoragePreservationClean/DryINT QtyUnit WeightUnit SizeUnit Pack CubeItem WeightItem Dims
PPZZXXX0.3 lbs
Preservation MaterialWrapping MaterialCushioning / DunnageCushioning ThicknessUnit ContainerIntermediate ContainerUnit Container LevelSpecial MarkingLevel A PackingLevel B PackingMinimal PackingOptional Procedure
X00QQO
Code Definitions

P

Packaging Data Source Code (PK_DTA_SRC_CD_5148)


Primary Inventory Control Activity (PICA)

P

Primary / Secondary Inventory Control Code (PICA_SICA_IND_5099)


Primary Inventory Control Activity (PICA)

ZZ

Method of Preservation Code (MTHD_PRSRV_CD_5160)


See J.4.1.b

XXX

Intermediate Container Quantity (INTMD_CTN_QTY_5152)

0.3 lbs

Unit Pack Weight (UP_WT_5153)

Unit Pack Cube (UP_CU_5155)

X

Thickness of Cushioning or Dunnage Code (THK_CUSH_DUN_5165)


As required to protect the item or elements of the package

00

Special Marking Code (SP_MKG_CD_5169)


No special marking

Q

Packing Requirement Code - For Level A (Maximum) Packing (LVL_A_PKG_CD_5170)


Packing shall be accomplished in accordance with table C.II for the packing level specified. Closure sealing and reinforcement shall be in accordance with applicable specification for shipping container.

Q

Packing Requirement Code - For Level B (Intermediate) Packing (LVL_B_PKG_CD_5171)


Packing shall be accomplished in accordance with table C-II for the packing level specified. Closure sealing and reinforcement shall be in accordance with the appropriate shipping container specification.

O

Optional Procedure Indicator Code (OPTNL_PRO_IND_5173)


Options can be exercised as to specific method of preservation or DoD approved packaging materials to be used. However, basic preservation method shall be retained, supplemental data shall be complied with, and unit package dimensions shall not be increased by more than one inch. Equal or better protection shall be given the item and there shall be no increase in the package cost.


FLIS - SEG M/V - CHARACTERISTICS DATA | NSN 5935-00-325-5106 Submit RFQ
MRCDecoded RequirementClear Text Reply
AFRVConnector Locking MethodJACKSCREW-SOCKET
CQTZContact MaterialCOPPER ALLOY SINGLE MATING END SINGLE CONTACT GROUPING
AFRDContact Maximum Ac Voltage Rating In Volts500.0 SINGLE MATING END SINGLE CONTACT GROUPING
AFRCContact Maximum Current Rating In Amps5.0 SINGLE MATING END SINGLE CONTACT GROUPING
CSGFContact Material Document And ClassificationQQ-C-530 FED SPEC SINGLE MATERIAL RESPONSE SINGLE MATING END SINGLE CONTACT GROUPING
AFQZContact RemovabilityNONREMOVABLE SINGLE MATING END SINGLE CONTACT GROUPING
AFREContact Maximum Dc Voltage Rating In Volts700.0 SINGLE MATING END SINGLE CONTACT GROUPING
AFQXContact Position Arrangement Style14-19 SINGLE MATING END
CRBJContact Surface Treatment Document And ClassificationMIL-G-45204 MIL SPEC SINGLE TREATMENT RESPONSE SINGLE MATING END SINGLE CONTACT GROUPING
CQYHContact Surface TreatmentGOLD SINGLE MATING END SINGLE CONTACT GROUPING
AAQLBody StyleSTRAIGHT SHAPE W/SCREW LOCKS
AFQWMating End Quantity1
CQJXNominal Thread Size0.086 INCHES AND 0.086 INCHES
CXCGIncluded Contact Quantity66 SINGLE MATING END SINGLE CONTACT GROUPING
CXCLIncluded Contact TypeROUND PIN SINGLE MATING END SINGLE CONTACT GROUPING
CQZGInsert MaterialPLASTIC DIALLYL PHTHALATE SINGLE MATING END
AFRNPolarization MethodJACKSCREW
PMLCPrecious Material And LocationCONTACT SURFACES GOLD
PMWTPrecious Material And Weight0.066 GOLD GRAINS, TROY
PRMTPrecious MaterialGOLD
ABKWOverall Height0.625 INCHES NOMINAL
ABHPOverall Length3.640 INCHES MINIMUM AND 3.660 INCHES MAXIMUM
ABMKOverall Width0.240 INCHES MINIMUM AND 0.260 INCHES MAXIMUM
CQTMTerminal LocationBACK SINGLE MATING END SINGLE CONTACT GROUPING
CSCFTerminal TypeTAB, SOLDER LUG SINGLE MATING END SINGLE CONTACT GROUPING
AAJFThread DirectionRIGHT-HAND AND RIGHT-HAND
AAJDThread Class2A AND 2B
THSDThread Series DesignatorUNC AND UNC
AFQRThreaded Device TypeCOUPLING FACILITY


Back to Top
Back to Top