5935-00-478-7254

CONNECTOR,RECEPTACLE,ELECTRICAL


5935-00-478-7254 (5935004787254, 004787254)
Part Numbers (16 listings): 16-00608-023 | GCM-17W5S | 499-056-165 | DCM17W5SA115C33 | DCM17W5SC31 | DCMM17W5S | 128C136H08 | 3P906754 | 3P906759 | 555146.095//N | DCM17W5S | 42361-050-00-0 | 01251-1286 | 414-1934-005 | 1757-3387 | 276-6067P049 |
Summary

FSG 59 / FSC 5935

DEMIL: A

DEMIL INT: 1

HMIC: P

Date Created: 22 Jan 1971

Unit Weight: 0.1 lbs

Unit Size: None

Unit Pack Cube: 0.013 cu ft

Replacement NSN:

5935-01-408-9744

Replacement Date: 12 Jun 1995

MSDS: None

Hazmat: None

Request a Quote


;



MASTER CROSS REFERENCE LIST (MCRL) | NSN 5935-00-478-7254 Submit RFQ
Manufacturer Part NumberRNCCRNVCManufacturer NameCAGE
16-00608-0233 - Design Control Reference2 - Production ItemRAYTHEON COMPANY  00724    CAGE 00724  
GCM-17W5S5 - Replaced / Discontinued2 - Production ItemCOOPER CROUSE- HINDS, LLC  25330      
499-056-1655 - Replaced / Discontinued2 - Production ItemINTERSTATE ELECTRONICS CORPORATION  07421    CAGE 07421  
DCM17W5SA115C335 - Replaced / Discontinued2 - Production ItemITT CORPORATION  71468    CAGE 71468  
DCM17W5SC315 - Replaced / Discontinued2 - Production ItemITT CORPORATION  71468    CAGE 71468  
DCMM17W5S5 - Replaced / Discontinued2 - Production ItemITT CORPORATION  71468    CAGE 71468  
DCMM17W5S5 - Replaced / Discontinued2 - Production ItemCINCH CONNECTORS, INC.  71785    CAGE 71785  
128C136H085 - Replaced / Discontinued2 - Production ItemNORTHROP GRUMMAN SYSTEMS CORPORATION  97942    CAGE 97942  
3P9067545 - Replaced / Discontinued2 - Production ItemTHALES OPTRONICS STAINES LTD  U5266      
3P9067595 - Replaced / Discontinued2 - Production ItemTHALES OPTRONICS STAINES LTD  U5266      
555146.095//N5 - Replaced / Discontinued2 - Production ItemSELEX ES SPA  A0069      
DCM17W5S5 - Replaced / Discontinued9 - No Longer UsedITT CORPORATION  71468    CAGE 71468  
555146.095//N5 - Replaced / Discontinued9 - No Longer UsedMARCONI MOBILE SPA EX ELMER SPA  A3026      
42361-050-00-05 - Replaced / Discontinued9 - No Longer UsedBRITISH AEROSPACE DEFENCE SYSTEMS  K4556    CAGE K4556  
01251-12865 - Replaced / Discontinued9 - No Longer UsedSOLRAC II INC  12848    CAGE 12848  
414-1934-0055 - Replaced / Discontinued9 - No Longer UsedBOEING COMPANY, THE  94756    CAGE 94756  
1757-3387C - Advisory Reference1 - Incomplete Part NumberLOCKHEED MARTIN CORP  08241    CAGE 08241  
42361-050-00-0C - Advisory Reference1 - Incomplete Part NumberBAE SYSTEMS INTEGRATED SYSTEM  KC1M9      
276-6067P049C - Advisory Reference1 - Incomplete Part NumberRAYTHEON COMPANY  49956    CAGE 49956  
Code Definitions

3 - Design Control Reference

Reference Number Category Code (DRN_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

5 - Replaced / Discontinued

Reference Number Category Code (DRN_2910)


Secondary Reference. Any additional number, other than a primary number (codes 1,2,3,4) informative reference (code 6) or vendor item drawing reference (code 7) assigned to an item of production or supply by a commercial or Government organization, which represents the same item of production or supply to which the National Stock Number (NSN) was assigned. The reference number may have had an RNCC of 1, 2, 3, 4 or 7 but has since been replaced in the item-of-supply concept of the NSN by another primary number.

C - Advisory Reference

Reference Number Category Code (DRN_2910)


Advisory Reference. A number assigned to an item of production or supply not included in the item-of-supply concept to which the NSN has been assigned (e.g., an item that may have been used in the preproduction equipment design which has since been redesigned or replaced). Use of this RNCC is restricted to conditions where cross-reference is required to establish identification to an item of supply. Additionally, there is not direct relationship of the reference number to the NSN other than a Service/Agency individual decision. (RNCC shall be used only in conjunction with RNVC 1.

2 - Production Item

Reference Number Variation Code (DRN_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.

9 - No Longer Used

Reference Number Variation Code (DRN_4780)


A specification, standard, or other reference number which is superseded, canceled, obsolete or discontinued and is coded Reference Number Category Code (RNCC) 5; a reference number for information only coded RNCC 6; or a reference number coded RNCC D.

1 - Incomplete Part Number

Reference Number Variation Code (DRN_4780)


A design control or other reference number that does NOT identify an item of production without the use of additional information, or a specific part, type, or similar reference number does NOT identify or item of supply without the use of additional information.


FLIS - SEG A - IDENTIFICATION | NSN 5935-00-478-7254 Submit RFQ
FSGFSCNIINFIIGINCCRITICALITYTYPE OF ITEMMRCDEMILHMICEDCPMICADPECDATE CREATED
595935004787254A039B015093X1APG22 Jan 1971
Code Definitions

59

Federal Supply Group (FSG_3994/FSC_WI_FSG_3996)


Electrical and Electronic Equipment Components

5935

Federal Supply Class (FSC_3994/FSC_WI_FSC_3996)


Connectors, Electrical

004787254

National Item Identification Number (NCB_CD_4130/I_I_NBR_4131)


NSN 5935-00-478-7254

A039B0

Federal Item Identification Guide (FIIG_4065)

15093

Item Naming Code (INC_4080)

22 Jan 1971

NIIN Assignment Date (DT_NIIN_ASGMT_2180)

X

Item Criticality (CRITL_CD_FIIG_3843)


The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.

1

Type of Item Identification (TYP_II_4820)


Full Descriptive Item Identification

A

Demilitarization Code (DEMIL_CD_0167)


Non-MLI/ Non-SLI — Demilitarization not required.

P

Hazardous Material Indicator Code (HMIC_0865)


Indicates there is no information in the HMIRS; however, the NSN is in a FSC in Table II of Federal Standard 313 and a MSDS may be required by the user. The requirement for a MSDS is dependent on a hazard determination of the supplier or the intended end use of the product.

G

Precious Metals Indicator Code (PMIC_0802)


Item contains gold.


FLIS - SEG B - MOE RULE DATA | NSN 5935-00-478-7254 Submit RFQ
MOE RuleFormer MOEAMCAMSCNIMSCIMCIMC ActivityAACDSORCollaboratorsReceiversEffective Date
YB011 Apr 1991
ZA011 Apr 1991
ZG011 Apr 1991
ZH011 Apr 1991
ZK011 Apr 1991
ZP011 Apr 1991
ZS011 Apr 1991
ZC011 Apr 1991
ZE011 Apr 1991
ZU011 Feb 1995
ZW011 Nov 1998
WB011 Aug 2006
WP011 Jun 2007
ZB011 Jun 2015
ZF011 Jun 2015
Code Definitions

FLIS - SEG C - REFERENCE NUMBER | NSN 5935-00-478-7254 Submit RFQ
RNFCRNCCRNVCDACRNAACRNSCRNJCSADCMSDSHCCReference NumberCAGE
1321TXD16-00608-023  00724   CAGE/00724
4525HDB499-056-165  07421   CAGE/07421
1526TXDGCM-17W5S  25330  
526TXDCM17W5SA115C33  71468   CAGE/71468
526TXDCM17W5SC31  71468   CAGE/71468
1526TXDDCMM17W5S  71468   CAGE/71468
1526TXDDCMM17W5S  71785   CAGE/71785
525TX128C136H08  97942   CAGE/97942
524ZBA555146.095//N  A0069  
4522ZKD3P906754  U5266  
4522ZKD3P906759  U5266  
596TXB01251-1286  12848   CAGE/12848
596TXBDCM17W5S  71468   CAGE/71468
4594ZBA555146.095//N  A3026  
1592ZKB42361-050-00-0  K4556   CAGE/K4556
595TXB414-1934-005  94756   CAGE/94756
C15TXAF276-6067P049  49956   CAGE/49956
1C1448B1757-3387  08241   CAGE/08241
1C12ZZD9F42361-050-00-0  KC1M9  
Code Definitions

1

Reference Number Format Code (RNFC_2920)


Number is formatted as configured on the originating document with the exception of the modification required in volume 2, chapter 2.9.Number is formatted as configured on the originating document with the exception of the modification required in volume 2, chapter 2.9 .

3

Reference Number Category Code (RNCC_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

2

Reference Number Variation Code (RNVC_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.

1

Document Availability Code (DAC_2640)


The reference number is represented by a drawing and the drawing was available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number. The RNAAC will furnish the drawing upon request.

TX

Reference Number Action Activity Code (RNAAC_2900)


Defense Supply Center Columbus, Columbus, OH 43218

D

Reference Number Status Code (RNSC_2923)


Procurement authority of the manufacturer and reference number have not yet been checked. NOTE: This code is to be allocated to reference numbers still requiring checks on procurement authority.

4

Reference Number Format Code (RNFC_2920)


Number is totally in-the-clear (without modification) as originally configured by the manufacturer, design control activity, or supplier.

5

Reference Number Category Code (RNCC_2910)


Secondary Reference. Any additional number, other than a primary number (codes 1,2,3,4) informative reference (code 6) or vendor item drawing reference (code 7) assigned to an item of production or supply by a commercial or Government organization, which represents the same item of production or supply to which the National Stock Number (NSN) was assigned. The reference number may have had an RNCC of 1, 2, 3, 4 or 7 but has since been replaced in the item-of-supply concept of the NSN by another primary number.

5

Document Availability Code (DAC_2640)


The reference number is represented by a drawing, but the drawing was not available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number.

HD

Reference Number Action Activity Code (RNAAC_2900)


Naval Inventory Control Point, Mechanicsburg, PA 17055-0788

B

Reference Number Status Code (RNSC_2923)


Manufacturer and/or reference number are not authorized for procurement. NOTE: This code may be used for obsolete or informative reference numbers only.

6

Document Availability Code (DAC_2640)


The reference number is represented by technical documentation other than a drawing but the documentation was not available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number.

4

Document Availability Code (DAC_2640)


The reference number is represented by technical documentation other than a drawing and the documentation was available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number; however, the RNAAC cannot furnish the technical documentation.

ZB

Reference Number Action Activity Code (RNAAC_2900)


Belgium

A

Reference Number Status Code (RNSC_2923)


Manufacturer and reference number are authorized for procurement. Under this reference number items can be procured only from the manufacturer identified by the NCAGE. NOTE: This code may only be used for reference numbers originating from manufacturers' standards or catalogs or for copyrighted drawing numbers.

2

Document Availability Code (DAC_2640)


The reference number is represented by a drawing and the drawing was available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number; however, the RNAAC cannot furnish the drawing.

ZK

Reference Number Action Activity Code (RNAAC_2900)


United Kingdom

9

Reference Number Variation Code (RNVC_4780)


A specification, standard, or other reference number which is superseded, canceled, obsolete or discontinued and is coded Reference Number Category Code (RNCC) 5; a reference number for information only coded RNCC 6; or a reference number coded RNCC D.

C

Reference Number Category Code (RNCC_2910)


Advisory Reference. A number assigned to an item of production or supply not included in the item-of-supply concept to which the NSN has been assigned (e.g., an item that may have been used in the preproduction equipment design which has since been redesigned or replaced). Use of this RNCC is restricted to conditions where cross-reference is required to establish identification to an item of supply. Additionally, there is not direct relationship of the reference number to the NSN other than a Service/Agency individual decision. (RNCC shall be used only in conjunction with RNVC 1.

1

Reference Number Variation Code (RNVC_4780)


A design control or other reference number that does NOT identify an item of production without the use of additional information, or a specific part, type, or similar reference number does NOT identify or item of supply without the use of additional information.

AF

Service / Agency Designator Code (SADC_4672)


Defense Logistics Agency

48

Reference Number Action Activity Code (RNAAC_2900)


Federal Aviation Administration, Oklahoma City, OK 73125

ZZ

Reference Number Action Activity Code (RNAAC_2900)


USA

9F

Service / Agency Designator Code (SADC_4672)


CAGE Status Change


FLIS - SEG E - ITEM STANDARDIZATION DATA | NSN 5935-00-478-7254 Submit RFQ
ISCOriginatorNIIN StatusReplaced / Replacement ISCReplaced / Replacement OriginatorReplacement NIIN StatusReplacement DateReplaced / Replacement NSNDecision Date
3TX11TX012 Jun 1995 5935014089744 12 Jun 1995
Code Definitions

3

Item Standardization Code (ISC_2650)


An item which, as a result of a formal item reduction study, is accepted as not authorized for procurement.

TX

Originator of Standardization Decision (ORG_STDZN_DEC_9325)


Defense Supply Center Columbus, Columbus, OH 43218

1

NIIN Status Code (NIIN_STAT_CD_2670)


Represents an item for which a U.S. activity proposed cancelled-invalid or cancelled-use action or that the NIIN Status Code be changed to 9, and one or more NATO/FC did not concur in the proposal. See volume 4, chapter 4.9.Item is restricted to North Atlantic Treaty Organization/foreign country (NATO/FC) use only.Represents an item for which a U.S. activity proposed cancelled-invalid or cancelled-use action or that the NIIN Status Code be changed to 9, and one or more NATO/FC did not concur in the proposal. Item is restricted to North Atlantic Treaty Organization/foreign country (NATO/FC) use only.

1

Replaced / Replacement Item Standardization Code (ISC_2650)


An item authorized for procurement as a result of a formal item reduction study and accepted as a replacement for one or more items not authorized for procurement. In addition, in generic relationships, a code 1 item is related to a code 2 item.

0

Replaced / Replacement NIIN Status Code (NIIN_STAT_CD_2670)


Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.

12 Jun 1995

Date of Replacement Standardization Decision (DT_STDZN_DEC_2300)

5935-01-408-9744

Replaced / Replacement NSN (RP_NSN_STD_RL_8977 / RPLM_NSN_STDZ_9525)

12 Jun 1995

Standardization Decision Date (DT_STDZN_DEC_2300)


FLIS - SEG G - FREIGHT DATA | NSN 5935-00-478-7254 Submit RFQ
IntegrityOriginatingHMCLCLWCCTCCSHCADCACCASHLTLNMFCNMFC Sub ItemUFCFreight DescriptionRail Variance
TX72DZ9AHZW061680Z34570ELEC-WIRING-PLUGS-ETC
Code Definitions

TX

Originating Activity Code (ORIG_ACTY_CD_4210)


Defense Supply Center Columbus, Columbus, OH 43218

72D

Water Commodity Code (WRT_CMDTY_CD_9275)


Communications/Electronics, other than SIGINT/EW or COMSEC. Repair Parts and Components

Z

Type Cargo Code (TYPE_CGO_CD_9260)


No special type of cargo code applicable

9

Special Handling Code (SP_HDLG_CD_9240)


No special handling required

A

Air Dimension Code (AIR_DIM_CD_9220)


Shipment is not a consolidation and does not exceed 72 inches in any dimension.

H

Air Commodity Code (AIR_CMTY_HDLG_9215)


Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.

Z

Air Special Handling Code (AIR_CMTY_HDLG_9215)


No special handling required.

W

Less Than Truckload (CLAS_RTNG_CD_2770)


Variable Rating

061680

National Motor Freight Classification Number (NMFC Item Number) (NMFC_2850)

Z

NMFC Sub Item Number (SUB_ITM_NBR_0861)

34570

Uniform Freight Classification (UFC_CD_MODF_3040)

ELEC-WIRING-PLUGS-ETC

Freight Description (FRT_DESC_4020)

Rail Variance

Rail Variance (RAIL_VARI_CD_4760)


No Variation. NMFC and UFCC Match.


FLIS - SEG H - MANAGEMENT DATA | NSN 5935-00-478-7254 Submit RFQ
Unit PriceMOESOSAACCIICQUPReparabilityUISLC
DNSMSYU1EA0
DSSMSYU1EA0
Code Definitions

SMS

Source of Supply (SOS_CD_3690) or Source of Supply Modifier (SOSM_CD_2948)


Defense Logistics Agency, Enterprise Business Systems

Y

Acquisition Advice Code (AAC_2507)


TERMINAL ITEM (NON-STOCKED ITEMS) Future procurement is not authorized. No wholesale stock is available for issue. 1. Requisitions will not be processed to the wholesale manager. 2. Internal Service/agency requisitioning may be continued in accordance with the Service/agency requisitioning policies.

U

Controlled Item Inventory Code (CIIC_2863)


Unclassified

1

Quantity Unit Pack (QUP_6106)


1

EA

Unit of Issue (UI_3050)


Each - A numeric quantity of one item of supply. Do not use if a more specific term applies, such as kit, set, assortment, assembly, group, sheet, plate, strip or length.

0

Shelf Life Code (SLC_2943)


TYPE I or TYPE II (Non-Deteriorative/No Shelf-Life) - An individual item of supply which is determined through an evaluation of technical test data and/or actual experience to be an item with a definite non-extendible period of shelf-life OR An individual item of supply having an assigned shelf-life time period that may be extended after completion of inspection/test/restorative action.

DN

Service / Agency Code (MOE_CD_2833)


Department of the Navy

DS

Service / Agency Code (MOE_CD_2833)


Defense Logistics Agency


FLIS - SEG W - PACKAGING DATA | NSN 5935-00-478-7254 Submit RFQ
SourcePICA / SICAPackaging CategoryStoragePreservationClean/DryINT QtyUnit WeightUnit SizeUnit Pack CubeItem WeightItem Dims
PPZZXXX0.1 lbs0.013 cu ft
Preservation MaterialWrapping MaterialCushioning / DunnageCushioning ThicknessUnit ContainerIntermediate ContainerUnit Container LevelSpecial MarkingLevel A PackingLevel B PackingMinimal PackingOptional Procedure
X00QQO
Code Definitions

P

Packaging Data Source Code (PK_DTA_SRC_CD_5148)


Primary Inventory Control Activity (PICA)

P

Primary / Secondary Inventory Control Code (PICA_SICA_IND_5099)


Primary Inventory Control Activity (PICA)

ZZ

Method of Preservation Code (MTHD_PRSRV_CD_5160)


See J.4.1.b

XXX

Intermediate Container Quantity (INTMD_CTN_QTY_5152)

0.1 lbs

Unit Pack Weight (UP_WT_5153)

0.013 cu ft

Unit Pack Cube (UP_CU_5155)

X

Thickness of Cushioning or Dunnage Code (THK_CUSH_DUN_5165)


As required to protect the item or elements of the package

00

Special Marking Code (SP_MKG_CD_5169)


No special marking

Q

Packing Requirement Code - For Level A (Maximum) Packing (LVL_A_PKG_CD_5170)


Packing shall be accomplished in accordance with table C.II for the packing level specified. Closure sealing and reinforcement shall be in accordance with applicable specification for shipping container.

Q

Packing Requirement Code - For Level B (Intermediate) Packing (LVL_B_PKG_CD_5171)


Packing shall be accomplished in accordance with table C-II for the packing level specified. Closure sealing and reinforcement shall be in accordance with the appropriate shipping container specification.

O

Optional Procedure Indicator Code (OPTNL_PRO_IND_5173)


Options can be exercised as to specific method of preservation or DoD approved packaging materials to be used. However, basic preservation method shall be retained, supplemental data shall be complied with, and unit package dimensions shall not be increased by more than one inch. Equal or better protection shall be given the item and there shall be no increase in the package cost.


FLIS - SEG M/V - CHARACTERISTICS DATA | NSN 5935-00-478-7254 Submit RFQ
MRCDecoded RequirementClear Text Reply
AFRVConnector Locking MethodSPRING FRICTION
CQTZContact MaterialCOPPER ALLOY SINGLE MATING END SINGLE CONTACT GROUPING
AFQZContact RemovabilityNONREMOVABLE SINGLE MATING END SINGLE CONTACT GROUPING
AFQXContact Position Arrangement Style"C,17W5" SINGLE MATING END
CQYHContact Surface TreatmentGOLD SINGLE MATING END SINGLE CONTACT GROUPING
AEJNDistance Between Mounting Facility Centers2.495 INCHES MINIMUM AND 2.505 INCHES MAXIMUM
AAQLBody StyleSTRAIGHT SHAPE
AFQWMating End Quantity1
CXCGIncluded Contact Quantity12 SINGLE MATING END SINGLE CONTACT GROUPING
CQZGInsert MaterialPLASTIC DIALLYL PHTHALATE SINGLE MATING END
AFRNPolarization MethodMATING END
PMLCPrecious Material And LocationCONTACT SURFACES GOLD
PRMTPrecious MaterialGOLD
PMWTPrecious Material And Weight0.012 GOLD GRAINS, TROY
CSPTShell MaterialSTEEL
CTBCShell Surface Treatment Document And ClassificationQQ-P-416,TYPE 2,CLASS 2 FED SPEC SINGLE TREATMENT RESPONSE
CSWMShell Surface TreatmentCADMIUM
AFRTShell TypeSOLID
ABKWOverall Height0.663 INCHES NOMINAL
ABHPOverall Length2.714 INCHES MINIMUM AND 2.744 INCHES MAXIMUM
ABMKOverall Width0.479 INCHES MINIMUM AND 0.509 INCHES MAXIMUM
AEBVUnthreaded Mounting Hole Diameter0.115 INCHES MINIMUM AND 0.125 INCHES MAXIMUM
CQTMTerminal LocationBACK SINGLE MATING END SINGLE CONTACT GROUPING
CSCFTerminal TypeSOLDER WELL SINGLE MATING END SINGLE CONTACT GROUPING


Back to Top
Back to Top