| Manufacturer Part Number | RNCC | RNVC | Manufacturer Name | CAGE | |
|---|---|---|---|---|---|
| 2815 | 3 - Design Control Reference | 2 - Production Item | HUBBELL INC | 74545 | |
Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.
A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.
| FSG | FSC | NIIN | FIIG | INC | CRITICALITY | TYPE OF ITEM | MRC | DEMIL | HMIC | EDC | PMIC | ADPEC | DATE CREATED |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 59 | 5935 | 005156964 | A039B0 | 15093 | X | 4 | 3 | A | P | A | 11 Aug 1974 |
The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Partial Descriptive Item Identification (Type 1 Concept)
An approved item name and FIIG exist but the item involved is so unique in design that it cannot be fully described in accordance with the FIIG.
Non-MLI/ Non-SLI — Demilitarization not required.
Indicates there is no information in the HMIRS; however, the NSN is in a FSC in Table II of Federal Standard 313 and a MSDS may be required by the user. The requirement for a MSDS is dependent on a hazard determination of the supplier or the intended end use of the product.
Item does not contain Precious Metal.
| MOE Rule | Former MOE | AMC | AMSC | NIMSC | IMC | IMC Activity | AAC | DSOR | Collaborators | Receivers | Effective Date | |||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| ZA01 | 1 Apr 1991 | |||||||||||||||||||||||||||||
| ZF01 | 1 Mar 2000 | |||||||||||||||||||||||||||||
| ZU01 | 1 Jul 2005 | |||||||||||||||||||||||||||||
| ISC | Originator | NIIN Status | Replaced / Replacement ISC | Replaced / Replacement Originator | Replacement NIIN Status | Replacement Date | Replaced / Replacement NSN | Decision Date |
|---|---|---|---|---|---|---|---|---|
| 3 | TX | 1 | 1 | TX | 0 | 2 Oct 1983 | 5935011863796 | 29 Sep 1983 |
An item which, as a result of a formal item reduction study, is accepted as not authorized for procurement.
Defense Supply Center Columbus, Columbus, OH 43218
Represents an item for which a U.S. activity proposed cancelled-invalid or cancelled-use action or that the NIIN Status Code be changed to 9, and one or more NATO/FC did not concur in the proposal. See volume 4, chapter 4.9.Item is restricted to North Atlantic Treaty Organization/foreign country (NATO/FC) use only.Represents an item for which a U.S. activity proposed cancelled-invalid or cancelled-use action or that the NIIN Status Code be changed to 9, and one or more NATO/FC did not concur in the proposal. Item is restricted to North Atlantic Treaty Organization/foreign country (NATO/FC) use only.
An item authorized for procurement as a result of a formal item reduction study and accepted as a replacement for one or more items not authorized for procurement. In addition, in generic relationships, a code 1 item is related to a code 2 item.
Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.
| Integrity | Originating | HMC | LCL | WCC | TCC | SHC | ADC | ACC | ASH | LTL | NMFC | NMFC Sub Item | UFC | Freight Description | Rail Variance |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 72D | Z | 9 | A | H | Z | W | 061680 | Z | 34570 | ELEC-WIRING-PLUGS-ETC |
Communications/Electronics, other than SIGINT/EW or COMSEC. Repair Parts and Components
No special type of cargo code applicable
No special handling required
Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
No special handling required.
Variable Rating
No Variation. NMFC and UFCC Match.
Defense Logistics Agency, Enterprise Business Systems
TERMINAL ITEM (NON-STOCKED ITEMS) Future procurement is not authorized. No wholesale stock is available for issue. 1. Requisitions will not be processed to the wholesale manager. 2. Internal Service/agency requisitioning may be continued in accordance with the Service/agency requisitioning policies.
Unclassified
No QUP
Each - A numeric quantity of one item of supply. Do not use if a more specific term applies, such as kit, set, assortment, assembly, group, sheet, plate, strip or length.
TYPE I or TYPE II (Non-Deteriorative/No Shelf-Life) - An individual item of supply which is determined through an evaluation of technical test data and/or actual experience to be an item with a definite non-extendible period of shelf-life OR An individual item of supply having an assigned shelf-life time period that may be extended after completion of inspection/test/restorative action.
Defense Logistics Agency
Department of the Navy
| MRC | Decoded Requirement | Clear Text Reply |
|---|---|---|
| ABKW | Overall Height | 2.266 INCHES NOMINAL |
| ADAV | Overall Diameter | 3.063 INCHES NOMINAL |
| AFRV | Connector Locking Method | CONTACT TWISTLOCK |
| AFRT | Shell Type | SOLID |
| CSPT | Shell Material | PLASTIC |
| AFRN | Polarization Method | CONTACT |
| AFQW | Mating End Quantity | 1 |
| CQZG | Insert Material | PLASTIC SINGLE MATING END |
| CXCG | Included Contact Quantity | 1 SINGLE MATING END 1ST CONTACT GROUPING |
| CXCG | Included Contact Quantity | 1 SINGLE MATING END 2ND CONTACT GROUPING |
| CXCG | Included Contact Quantity | 3 SINGLE MATING END 3RD CONTACT GROUPING |
| AFQZ | Contact Removability | NONREMOVABLE SINGLE MATING END SINGLE CONTACT GROUPING |
| AFRC | Contact Maximum Current Rating In Amps | 30.0 SINGLE MATING END SINGLE CONTACT GROUPING |
| AFRD | Contact Maximum Ac Voltage Rating In Volts | 208.0 SINGLE MATING END SINGLE CONTACT GROUPING |
| CSCF | Terminal Type | SCREW SINGLE MATING END SINGLE CONTACT GROUPING |
| CQTM | Terminal Location | BACK SINGLE MATING END SINGLE CONTACT GROUPING |